{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:msve_etds-1074"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:msve_etds-1074","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Fine-Tuning of Mass-Spring Model Properties for Simulating Realistic Soft Body Deformation","abstract":"Obtaining a well behaved soft-tissue model is one of the most challenging and important tasks in the development of surgical simulation systems. Achieving both accurate and real-time deformation response from a soft-tissue model becomes more difficult as the complexity of the represented anatomy and the degree of deformation increases. One common approach to modeling deformable objects is the Mass-Spring (MS) system method. Mass-Spring systems are attractive to real-time applications due to their relatively low computational requirement and ease of implementation. However, their parameter determination is typically done manually, which becomes tedious when accurate approximation to real-world objects is desired. This thesis will focus on making MS model tuning a less tedious procedure by developing a tool that allows its users to explore the effects on the deformation behavior by altering various parameters. Providing the geometry information of the soft object together with its mass and coefficient of stiffness, the users of this toolkit will be presented with a virtual deformable model. This model can be interacted with through a haptic device. A number of parameters, for which the program provides default values, can then be adjusted during a testing session. These include the spring stiffness constants, damping factor, percentage of deformation, and time-step for numerical integration. The users can test the behavior of the new setup any time a parameter is changed. After each test the average frame rate is displayed. When the model behavior and the frame rate achieved are satisfactory, the configuration can be saved into a text file and returned to for later comparison by retrieving/loading the settings from this file. The users of this tool will benefit by being able to minimize the time of MS model tuning, which is a necessary task when accuracy is critical.","abstract_html":"Obtaining a well behaved soft-tissue model is one of the most challenging and important tasks in the development of surgical simulation systems. Achieving both accurate and real-time deformation response from a soft-tissue model becomes more difficult as the complexity of the represented anatomy and the degree of deformation increases. One common approach to modeling deformable objects is the Mass-Spring (MS) system method. Mass-Spring systems are attractive to real-time applications due to their relatively low computational requirement and ease of implementation. However, their parameter determination is typically done manually, which becomes tedious when accurate approximation to real-world objects is desired. This thesis will focus on making MS model tuning a less tedious procedure by developing a tool that allows its users to explore the effects on the deformation behavior by altering various parameters. Providing the geometry information of the soft object together with its mass and coefficient of stiffness, the users of this toolkit will be presented with a virtual deformable model. This model can be interacted with through a haptic device. A number of parameters, for which the program provides default values, can then be adjusted during a testing session. These include the spring stiffness constants, damping factor, percentage of deformation, and time-step for numerical integration. The users can test the behavior of the new setup any time a parameter is changed. After each test the average frame rate is displayed. When the model behavior and the frame rate achieved are satisfactory, the configuration can be saved into a text file and returned to for later comparison by retrieving/loading the settings from this file. The users of this tool will benefit by being able to minimize the time of MS model tuning, which is a necessary task when accuracy is critical.","abstract_has_math":false,"creators":["Girtelschmid, Sylva A."],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Computational Modeling & Simulation Engineering","degree_department":null,"school":null,"contributors":["Frederic D. mcKenzie","Bowen Loftin","Lee A. Belfore, II"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T04:11:43Z","subjects":["Surgical instruments","Tissues","Computational Engineering","Computer Engineering","Numerical Analysis and Scientific Computing"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/msve_etds/74","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/msve_etds/74","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aodu%3Aoai%3Adigitalcommons.odu.edu%3Amsve_etds-1074","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Amsve_etds-1074","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Frederic D. mcKenzie","Bowen Loftin","Lee A. Belfore, II"]},{"key":"dc:creator","label":"Author","values":["Girtelschmid, Sylva A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-01-04T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2005-07-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Computational Modeling & Simulation Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Surgical instruments","Tissues","Computational Engineering","Computer Engineering","Numerical Analysis and Scientific Computing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.odu.edu/msve_etds/74"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Obtaining a well behaved soft-tissue model is one of the most challenging and important tasks in the development of surgical simulation systems. Achieving both accurate and real-time deformation response from a soft-tissue model becomes more difficult as the complexity of the represented anatomy and the degree of deformation increases. One common approach to modeling deformable objects is the Mass-Spring (MS) system method. Mass-Spring systems are attractive to real-time applications due to their relatively low computational requirement and ease of implementation. However, their parameter determination is typically done manually, which becomes tedious when accurate approximation to real-world objects is desired. This thesis will focus on making MS model tuning a less tedious procedure by developing a tool that allows its users to explore the effects on the deformation behavior by altering various parameters. Providing the geometry information of the soft object together with its mass and coefficient of stiffness, the users of this toolkit will be presented with a virtual deformable model. This model can be interacted with through a haptic device. A number of parameters, for which the program provides default values, can then be adjusted during a testing session. These include the spring stiffness constants, damping factor, percentage of deformation, and time-step for numerical integration. The users can test the behavior of the new setup any time a parameter is changed. After each test the average frame rate is displayed. When the model behavior and the frame rate achieved are satisfactory, the configuration can be saved into a text file and returned to for later comparison by retrieving/loading the settings from this file. The users of this tool will benefit by being able to minimize the time of MS model tuning, which is a necessary task when accuracy is critical."]},{"key":"dc:title","label":"Title","values":["Fine-Tuning of Mass-Spring Model Properties for Simulating Realistic Soft Body Deformation"]}]}],"canonical_facts":{"dc:contributor":["Frederic D. mcKenzie","Bowen Loftin","Lee A. Belfore, II"],"dc:creator":["Girtelschmid, Sylva A."],"dc:date.available":["2024-01-04T08:00:00Z"],"dc:date.created":["2005-07-01T07:00:00Z"],"dc:description.abstract":["Obtaining a well behaved soft-tissue model is one of the most challenging and important tasks in the development of surgical simulation systems. Achieving both accurate and real-time deformation response from a soft-tissue model becomes more difficult as the complexity of the represented anatomy and the degree of deformation increases. One common approach to modeling deformable objects is the Mass-Spring (MS) system method. Mass-Spring systems are attractive to real-time applications due to their relatively low computational requirement and ease of implementation. However, their parameter determination is typically done manually, which becomes tedious when accurate approximation to real-world objects is desired. This thesis will focus on making MS model tuning a less tedious procedure by developing a tool that allows its users to explore the effects on the deformation behavior by altering various parameters. Providing the geometry information of the soft object together with its mass and coefficient of stiffness, the users of this toolkit will be presented with a virtual deformable model. This model can be interacted with through a haptic device. A number of parameters, for which the program provides default values, can then be adjusted during a testing session. These include the spring stiffness constants, damping factor, percentage of deformation, and time-step for numerical integration. The users can test the behavior of the new setup any time a parameter is changed. After each test the average frame rate is displayed. When the model behavior and the frame rate achieved are satisfactory, the configuration can be saved into a text file and returned to for later comparison by retrieving/loading the settings from this file. The users of this tool will benefit by being able to minimize the time of MS model tuning, which is a necessary task when accuracy is critical."],"dc:identifier":["https://digitalcommons.odu.edu/msve_etds/74"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Surgical instruments","Tissues","Computational Engineering","Computer Engineering","Numerical Analysis and Scientific Computing"],"dc:title":["Fine-Tuning of Mass-Spring Model Properties for Simulating Realistic Soft Body Deformation"],"thesis:degree_discipline":["Computational Modeling & Simulation Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-27T04:11:43Z"}