{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:pt_etds-1020"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:pt_etds-1020","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Reliability of the Modified-Modified Schober Method of Measuring Lumbar Range of Motion","abstract":"The purpose of this study was to determine the reliability of the Modified-modified Schober (MMS) method of measuring lumbar flexion and extension on subjects with low back pain. Thirty patients (19 females, 11 males) between the ages of 18 to 61 years (mean=40.0, SD=l 1.7) were measured by two physical therapists who each had six years of orthopedic experience. Each subject was evaluated twice, in random order, by each tester using the MMS method. Trials 1 and 2 were used to calculate intratester reliability for each tester and intertester reliability was calculated between the two testers. Intraclass correlation coefficients (ICCs) for intratester reliability during flexion were .98 and .93 for tester 1 and 2, respectively. ICCs for intratester reliability during extension were .96 and .91 for tester 1 and 2, respectively. Intertester reliability was .93 and .83 for lumbar flexion and extension, respectively. The MMS method appears to be a reliable method of measuring lumbar flexion and extension in patients with low back pain.","abstract_html":"The purpose of this study was to determine the reliability of the Modified-modified Schober (MMS) method of measuring lumbar flexion and extension on subjects with low back pain. Thirty patients (19 females, 11 males) between the ages of 18 to 61 years (mean=40.0, SD=l 1.7) were measured by two physical therapists who each had six years of orthopedic experience. Each subject was evaluated twice, in random order, by each tester using the MMS method. Trials 1 and 2 were used to calculate intratester reliability for each tester and intertester reliability was calculated between the two testers. Intraclass correlation coefficients (ICCs) for intratester reliability during flexion were .98 and .93 for tester 1 and 2, respectively. ICCs for intratester reliability during extension were .96 and .91 for tester 1 and 2, respectively. Intertester reliability was .93 and .83 for lumbar flexion and extension, respectively. The MMS method appears to be a reliable method of measuring lumbar flexion and extension in patients with low back pain.","abstract_has_math":false,"creators":["Mariano, Mira H."],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Rehabilitation Sciences","degree_department":null,"school":null,"contributors":["John L. Echternach","Martha L. Walker","Gail Grisetti"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T04:11:12Z","subjects":["Backache","Lumbar vertebrae","Exercise therapy","Exercise Physiology","Exercise Science","Physical Therapy"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/pt_etds/21","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/pt_etds/21","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aodu%3Aoai%3Adigitalcommons.odu.edu%3Apt_etds-1020","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Apt_etds-1020","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["John L. Echternach","Martha L. Walker","Gail Grisetti"]},{"key":"dc:creator","label":"Author","values":["Mariano, Mira H."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-09-14T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1997-08-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Rehabilitation Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Backache","Lumbar vertebrae","Exercise therapy","Exercise Physiology","Exercise Science","Physical Therapy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.odu.edu/pt_etds/21"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this study was to determine the reliability of the Modified-modified Schober (MMS) method of measuring lumbar flexion and extension on subjects with low back pain. Thirty patients (19 females, 11 males) between the ages of 18 to 61 years (mean=40.0, SD=l 1.7) were measured by two physical therapists who each had six years of orthopedic experience. Each subject was evaluated twice, in random order, by each tester using the MMS method. Trials 1 and 2 were used to calculate intratester reliability for each tester and intertester reliability was calculated between the two testers. Intraclass correlation coefficients (ICCs) for intratester reliability during flexion were .98 and .93 for tester 1 and 2, respectively. ICCs for intratester reliability during extension were .96 and .91 for tester 1 and 2, respectively. Intertester reliability was .93 and .83 for lumbar flexion and extension, respectively. The MMS method appears to be a reliable method of measuring lumbar flexion and extension in patients with low back pain."]},{"key":"dc:title","label":"Title","values":["Reliability of the Modified-Modified Schober Method of Measuring Lumbar Range of Motion"]}]}],"canonical_facts":{"dc:contributor":["John L. Echternach","Martha L. Walker","Gail Grisetti"],"dc:creator":["Mariano, Mira H."],"dc:date.available":["2023-09-14T07:00:00Z"],"dc:date.created":["1997-08-01T07:00:00Z"],"dc:description.abstract":["The purpose of this study was to determine the reliability of the Modified-modified Schober (MMS) method of measuring lumbar flexion and extension on subjects with low back pain. Thirty patients (19 females, 11 males) between the ages of 18 to 61 years (mean=40.0, SD=l 1.7) were measured by two physical therapists who each had six years of orthopedic experience. Each subject was evaluated twice, in random order, by each tester using the MMS method. Trials 1 and 2 were used to calculate intratester reliability for each tester and intertester reliability was calculated between the two testers. Intraclass correlation coefficients (ICCs) for intratester reliability during flexion were .98 and .93 for tester 1 and 2, respectively. ICCs for intratester reliability during extension were .96 and .91 for tester 1 and 2, respectively. Intertester reliability was .93 and .83 for lumbar flexion and extension, respectively. The MMS method appears to be a reliable method of measuring lumbar flexion and extension in patients with low back pain."],"dc:identifier":["https://digitalcommons.odu.edu/pt_etds/21"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Backache","Lumbar vertebrae","Exercise therapy","Exercise Physiology","Exercise Science","Physical Therapy"],"dc:title":["Reliability of the Modified-Modified Schober Method of Measuring Lumbar Range of Motion"],"thesis:degree_discipline":["Rehabilitation Sciences"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-27T04:11:12Z"}