{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1147750068"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1147750068","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Microbial Biofilm and Bacterial Endotoxin Adhesion to Zirconium Surfaces","abstract":"The purpose of this project was to investigate how zirconium alloys resist microbial biofilm formation and endotoxin adhesion in a simulated biological system. With the intent of potentially developing this class of alloys for orthopedic implant applications, it was necessary to determine their stability in a biological environment. Because zirconium alloys have been shown to demonstrate chemical stability in industrial applications, it follows that their corrosion resistant properties have the potential to transfer to biological systems. The analytical scope of this project assessed the ability of un-oxidized Zirconium-705 (Zr-705), thermally processed Zr-705, and thermally processed Zircaloy-2 (Zry-2) to resist biofilm formation and endotoxin adhesion by clinical strains of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Candida albicans, and all four in combination. Microbial analysis specifically involved viable counts and the limulus amebocyte lysate gel clot assay. Statistical analyses revealed that the thermally processed 4µm Zr-705, when compared to un-oxidized Zr-705, 2µm Zr-705, and 4µm Zry-2, demonstrated an overall greater resistance to microbial biofilm formation. The 4µm Zry-2, albeit statistically not significant, was optimal in deterring bacterial endotoxin adhesion. Further, a shaken incubation condition, on average, was significantly more effective than a stationary incubation condition in resisting microbial and endotoxin adhesion. This project demonstrated the potential usefulness of zirconium alloys for orthopedic implants.","abstract_html":"The purpose of this project was to investigate how zirconium alloys resist microbial biofilm formation and endotoxin adhesion in a simulated biological system. With the intent of potentially developing this class of alloys for orthopedic implant applications, it was necessary to determine their stability in a biological environment. Because zirconium alloys have been shown to demonstrate chemical stability in industrial applications, it follows that their corrosion resistant properties have the potential to transfer to biological systems. The analytical scope of this project assessed the ability of un-oxidized Zirconium-705 (Zr-705), thermally processed Zr-705, and thermally processed Zircaloy-2 (Zry-2) to resist biofilm formation and endotoxin adhesion by clinical strains of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Candida albicans, and all four in combination. Microbial analysis specifically involved viable counts and the limulus amebocyte lysate gel clot assay. Statistical analyses revealed that the thermally processed 4µm Zr-705, when compared to un-oxidized Zr-705, 2µm Zr-705, and 4µm Zry-2, demonstrated an overall greater resistance to microbial biofilm formation. The 4µm Zry-2, albeit statistically not significant, was optimal in deterring bacterial endotoxin adhesion. Further, a shaken incubation condition, on average, was significantly more effective than a stationary incubation condition in resisting microbial and endotoxin adhesion. This project demonstrated the potential usefulness of zirconium alloys for orthopedic implants.","abstract_has_math":false,"creators":["Buczynski, Bradley W."],"institution":"University of Akron","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biology","degree_department":null,"school":null,"contributors":[],"advisors":["Kory, Dr. Martha"],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006-10-05","date_published":"2006-10-05","updated_at":"2026-11-27T04:13:04Z","subjects":["Biology, Microbiology","ENDOTOXIN","Zr-705","BIOFILM","4¿¿¿¿m","incubation condition","MICROBIAL","viable counts"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1147750068","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1147750068","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1147750068","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1147750068","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kory, Dr. Martha"]},{"key":"dc:creator","label":"Author","values":["Buczynski, Bradley W."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2006-10-05"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biology, Microbiology","ENDOTOXIN","Zr-705","BIOFILM","4¿¿¿¿m","incubation condition","MICROBIAL","viable counts"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1147750068"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The purpose of this project was to investigate how zirconium alloys resist microbial biofilm formation and endotoxin adhesion in a simulated biological system. With the intent of potentially developing this class of alloys for orthopedic implant applications, it was necessary to determine their stability in a biological environment. Because zirconium alloys have been shown to demonstrate chemical stability in industrial applications, it follows that their corrosion resistant properties have the potential to transfer to biological systems. The analytical scope of this project assessed the ability of un-oxidized Zirconium-705 (Zr-705), thermally processed Zr-705, and thermally processed Zircaloy-2 (Zry-2) to resist biofilm formation and endotoxin adhesion by clinical strains of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Candida albicans, and all four in combination. Microbial analysis specifically involved viable counts and the limulus amebocyte lysate gel clot assay. Statistical analyses revealed that the thermally processed 4µm Zr-705, when compared to un-oxidized Zr-705, 2µm Zr-705, and 4µm Zry-2, demonstrated an overall greater resistance to microbial biofilm formation. The 4µm Zry-2, albeit statistically not significant, was optimal in deterring bacterial endotoxin adhesion. Further, a shaken incubation condition, on average, was significantly more effective than a stationary incubation condition in resisting microbial and endotoxin adhesion. This project demonstrated the potential usefulness of zirconium alloys for orthopedic implants."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.55","297.4 KB"]},{"key":"dc:title","label":"Title","values":["Microbial Biofilm and Bacterial Endotoxin Adhesion to Zirconium Surfaces"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kory, Dr. Martha"],"dc:creator":["Buczynski, Bradley W."],"dc:date":["2006-10-05"],"dc:description":["The purpose of this project was to investigate how zirconium alloys resist microbial biofilm formation and endotoxin adhesion in a simulated biological system. With the intent of potentially developing this class of alloys for orthopedic implant applications, it was necessary to determine their stability in a biological environment. Because zirconium alloys have been shown to demonstrate chemical stability in industrial applications, it follows that their corrosion resistant properties have the potential to transfer to biological systems. The analytical scope of this project assessed the ability of un-oxidized Zirconium-705 (Zr-705), thermally processed Zr-705, and thermally processed Zircaloy-2 (Zry-2) to resist biofilm formation and endotoxin adhesion by clinical strains of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Candida albicans, and all four in combination. Microbial analysis specifically involved viable counts and the limulus amebocyte lysate gel clot assay. Statistical analyses revealed that the thermally processed 4µm Zr-705, when compared to un-oxidized Zr-705, 2µm Zr-705, and 4µm Zry-2, demonstrated an overall greater resistance to microbial biofilm formation. The 4µm Zry-2, albeit statistically not significant, was optimal in deterring bacterial endotoxin adhesion. Further, a shaken incubation condition, on average, was significantly more effective than a stationary incubation condition in resisting microbial and endotoxin adhesion. This project demonstrated the potential usefulness of zirconium alloys for orthopedic implants."],"dc:format":["application/pdf","p.55","297.4 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1147750068"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biology, Microbiology","ENDOTOXIN","Zr-705","BIOFILM","4¿¿¿¿m","incubation condition","MICROBIAL","viable counts"],"dc:title":["Microbial Biofilm and Bacterial Endotoxin Adhesion to Zirconium Surfaces"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biology"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:04Z"}