{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1155133077"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1155133077","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Significance of the Initial Mechanical Stability for the Fracture Fixation System – A Biomechanical Analysis of Two Generations of Dynamic Compression (DCP) Bone Plate Systems","abstract":"Surgical fixation of bone fractures by Open Reduction and Internal fixation (ORIF) employing metal plates, screws, and pins is an established operative technique. Internal fixation hardware provides excellent reduction of the bone fragments and necessary strength to stabilize the fracture, allowing for early patient mobility. However, uncontrolled interfragmentary movement and stress shielding may defeat the purpose of primary contact healing using osteosynthesis implants and has been reported to result in delayed or malunion of the bone. Most of the factors, which affect the course of primary healing, are influenced by the initial mechanical stability of the fracture construct The purpose of this study was to compare a prototype (OrthoHelix MaxLock<sup>®</sup>) dynamic compression (DCP) bone plate construct to that of an FDA approved DePuy DCP construct with respect to specific parameters and phenomenon influencing mechanical stability of the construct. Construct stiffness, plate strain, and interfragmentary movement (gap micromotion) at fracture site were investigated in 4-point bending of synthetic bone constructs and further in a canine fracture model. On the two closing configurations of the construct (clinically significant sites) the difference in the resulting mean normalized stiffness was 5% and 10% higher for MaxLock as compared DePuy. The mean interfragmentary movement (gap micromotion) was about 55-60% lesser for MaxLock than DePuy for the same two configurations. However, for the two crack opening configurations the mean construct stiffness for MaxLock was 40% lesser then DePuy, and consequently higher plate strains were observed.","abstract_html":"Surgical fixation of bone fractures by Open Reduction and Internal fixation (ORIF) employing metal plates, screws, and pins is an established operative technique. Internal fixation hardware provides excellent reduction of the bone fragments and necessary strength to stabilize the fracture, allowing for early patient mobility. However, uncontrolled interfragmentary movement and stress shielding may defeat the purpose of primary contact healing using osteosynthesis implants and has been reported to result in delayed or malunion of the bone. Most of the factors, which affect the course of primary healing, are influenced by the initial mechanical stability of the fracture construct The purpose of this study was to compare a prototype (OrthoHelix MaxLock&lt;sup&gt;®&lt;/sup&gt;) dynamic compression (DCP) bone plate construct to that of an FDA approved DePuy DCP construct with respect to specific parameters and phenomenon influencing mechanical stability of the construct. Construct stiffness, plate strain, and interfragmentary movement (gap micromotion) at fracture site were investigated in 4-point bending of synthetic bone constructs and further in a canine fracture model. On the two closing configurations of the construct (clinically significant sites) the difference in the resulting mean normalized stiffness was 5% and 10% higher for MaxLock as compared DePuy. The mean interfragmentary movement (gap micromotion) was about 55-60% lesser for MaxLock than DePuy for the same two configurations. However, for the two crack opening configurations the mean construct stiffness for MaxLock was 40% lesser then DePuy, and consequently higher plate strains were observed.","abstract_has_math":false,"creators":["Choithramani, Hitesh R."],"institution":"University of Akron","degree_name":"Master of Science in Engineering","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Njus, Glen"],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006-10-05","date_published":"2006-10-05","updated_at":"2026-11-27T04:13:04Z","subjects":[],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1155133077","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1155133077","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1155133077","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1155133077","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Njus, Glen"]},{"key":"dc:creator","label":"Author","values":["Choithramani, Hitesh R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2006-10-05"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1155133077"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Surgical fixation of bone fractures by Open Reduction and Internal fixation (ORIF) employing metal plates, screws, and pins is an established operative technique. Internal fixation hardware provides excellent reduction of the bone fragments and necessary strength to stabilize the fracture, allowing for early patient mobility. However, uncontrolled interfragmentary movement and stress shielding may defeat the purpose of primary contact healing using osteosynthesis implants and has been reported to result in delayed or malunion of the bone. Most of the factors, which affect the course of primary healing, are influenced by the initial mechanical stability of the fracture construct The purpose of this study was to compare a prototype (OrthoHelix MaxLock<sup>®</sup>) dynamic compression (DCP) bone plate construct to that of an FDA approved DePuy DCP construct with respect to specific parameters and phenomenon influencing mechanical stability of the construct. Construct stiffness, plate strain, and interfragmentary movement (gap micromotion) at fracture site were investigated in 4-point bending of synthetic bone constructs and further in a canine fracture model. On the two closing configurations of the construct (clinically significant sites) the difference in the resulting mean normalized stiffness was 5% and 10% higher for MaxLock as compared DePuy. The mean interfragmentary movement (gap micromotion) was about 55-60% lesser for MaxLock than DePuy for the same two configurations. However, for the two crack opening configurations the mean construct stiffness for MaxLock was 40% lesser then DePuy, and consequently higher plate strains were observed."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.129","14.98 MB"]},{"key":"dc:title","label":"Title","values":["Significance of the Initial Mechanical Stability for the Fracture Fixation System – A Biomechanical Analysis of Two Generations of Dynamic Compression (DCP) Bone Plate Systems"]}]}],"canonical_facts":{"dc:contributor.advisor":["Njus, Glen"],"dc:creator":["Choithramani, Hitesh R."],"dc:date":["2006-10-05"],"dc:description":["Surgical fixation of bone fractures by Open Reduction and Internal fixation (ORIF) employing metal plates, screws, and pins is an established operative technique. Internal fixation hardware provides excellent reduction of the bone fragments and necessary strength to stabilize the fracture, allowing for early patient mobility. However, uncontrolled interfragmentary movement and stress shielding may defeat the purpose of primary contact healing using osteosynthesis implants and has been reported to result in delayed or malunion of the bone. Most of the factors, which affect the course of primary healing, are influenced by the initial mechanical stability of the fracture construct The purpose of this study was to compare a prototype (OrthoHelix MaxLock<sup>®</sup>) dynamic compression (DCP) bone plate construct to that of an FDA approved DePuy DCP construct with respect to specific parameters and phenomenon influencing mechanical stability of the construct. Construct stiffness, plate strain, and interfragmentary movement (gap micromotion) at fracture site were investigated in 4-point bending of synthetic bone constructs and further in a canine fracture model. On the two closing configurations of the construct (clinically significant sites) the difference in the resulting mean normalized stiffness was 5% and 10% higher for MaxLock as compared DePuy. The mean interfragmentary movement (gap micromotion) was about 55-60% lesser for MaxLock than DePuy for the same two configurations. However, for the two crack opening configurations the mean construct stiffness for MaxLock was 40% lesser then DePuy, and consequently higher plate strains were observed."],"dc:format":["application/pdf","p.129","14.98 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1155133077"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:title":["Significance of the Initial Mechanical Stability for the Fracture Fixation System – A Biomechanical Analysis of Two Generations of Dynamic Compression (DCP) Bone Plate Systems"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:04Z"}