{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1164666232"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1164666232","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"IMPLEMENTATION OF INTERACTIVE REMOTE PHYSIOLOGICAL MONITORING AND FEEDBACK TRAINING SYSTEM","abstract":"Remote Physiological Monitoring as an application of telemedicine holds great promise for providing efficient and economical health care. Most telemedicine applications have been limited to the use of interactive video for physician consultations, educational, research and administrative purposes. In this research project, an attempt was made to design and implement software that provided an interactive remote physiological monitoring system with instantaneous feedback to the physician at any remote location, about the general health of the patient, through the internet. The software acquired sixteen channels of raw physiological signals and provided twenty parameters, which included heart rate, blood pressure, temperature and respiratory rate, describing the physiological condition of the patient. Reliable algorithms were implemented for the processing of raw physiological signals to provide accurate values of useful physiological parameters. The remote communication between the physician end and the patient end was achieved using the Transmission Control Protocol/Internet Protocol (TCP/IP). The data acquisition, signal processing and display of the processed output at patient’s site were controlled by the physician at the remote site. The design of software was such that, it was interchangeably used for patient monitoring as well as training of subjects to control their physiological responses to various environmental stressors. The software was designed and implemented in the Microsoft Visual Basic 6.0® Integrated Development Environment.","abstract_html":"Remote Physiological Monitoring as an application of telemedicine holds great promise for providing efficient and economical health care. Most telemedicine applications have been limited to the use of interactive video for physician consultations, educational, research and administrative purposes. In this research project, an attempt was made to design and implement software that provided an interactive remote physiological monitoring system with instantaneous feedback to the physician at any remote location, about the general health of the patient, through the internet. The software acquired sixteen channels of raw physiological signals and provided twenty parameters, which included heart rate, blood pressure, temperature and respiratory rate, describing the physiological condition of the patient. Reliable algorithms were implemented for the processing of raw physiological signals to provide accurate values of useful physiological parameters. The remote communication between the physician end and the patient end was achieved using the Transmission Control Protocol/Internet Protocol (TCP/IP). The data acquisition, signal processing and display of the processed output at patient’s site were controlled by the physician at the remote site. The design of software was such that, it was interchangeably used for patient monitoring as well as training of subjects to control their physiological responses to various environmental stressors. The software was designed and implemented in the Microsoft Visual Basic 6.0® Integrated Development Environment.","abstract_has_math":false,"creators":["Syed Shah, Nemath Farhan"],"institution":"University of Akron","degree_name":"Master of Science in Engineering","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Taylor, Bruce"],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006","date_published":"2006","updated_at":"2026-11-27T04:13:04Z","subjects":["QRS","volume pulse","QRS detection","heart rate","dZ/dt","blood pressure","respiratory rate"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1164666232","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1164666232","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1164666232","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1164666232","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Taylor, Bruce"]},{"key":"dc:creator","label":"Author","values":["Syed Shah, Nemath Farhan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2006"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["QRS","volume pulse","QRS detection","heart rate","dZ/dt","blood pressure","respiratory rate"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1164666232"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Remote Physiological Monitoring as an application of telemedicine holds great promise for providing efficient and economical health care. Most telemedicine applications have been limited to the use of interactive video for physician consultations, educational, research and administrative purposes. In this research project, an attempt was made to design and implement software that provided an interactive remote physiological monitoring system with instantaneous feedback to the physician at any remote location, about the general health of the patient, through the internet. The software acquired sixteen channels of raw physiological signals and provided twenty parameters, which included heart rate, blood pressure, temperature and respiratory rate, describing the physiological condition of the patient. Reliable algorithms were implemented for the processing of raw physiological signals to provide accurate values of useful physiological parameters. The remote communication between the physician end and the patient end was achieved using the Transmission Control Protocol/Internet Protocol (TCP/IP). The data acquisition, signal processing and display of the processed output at patient’s site were controlled by the physician at the remote site. The design of software was such that, it was interchangeably used for patient monitoring as well as training of subjects to control their physiological responses to various environmental stressors. The software was designed and implemented in the Microsoft Visual Basic 6.0® Integrated Development Environment."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","4. MB"]},{"key":"dc:title","label":"Title","values":["IMPLEMENTATION OF INTERACTIVE REMOTE PHYSIOLOGICAL MONITORING AND FEEDBACK TRAINING SYSTEM"]}]}],"canonical_facts":{"dc:contributor.advisor":["Taylor, Bruce"],"dc:creator":["Syed Shah, Nemath Farhan"],"dc:date":["2006"],"dc:description":["Remote Physiological Monitoring as an application of telemedicine holds great promise for providing efficient and economical health care. Most telemedicine applications have been limited to the use of interactive video for physician consultations, educational, research and administrative purposes. In this research project, an attempt was made to design and implement software that provided an interactive remote physiological monitoring system with instantaneous feedback to the physician at any remote location, about the general health of the patient, through the internet. The software acquired sixteen channels of raw physiological signals and provided twenty parameters, which included heart rate, blood pressure, temperature and respiratory rate, describing the physiological condition of the patient. Reliable algorithms were implemented for the processing of raw physiological signals to provide accurate values of useful physiological parameters. The remote communication between the physician end and the patient end was achieved using the Transmission Control Protocol/Internet Protocol (TCP/IP). The data acquisition, signal processing and display of the processed output at patient’s site were controlled by the physician at the remote site. The design of software was such that, it was interchangeably used for patient monitoring as well as training of subjects to control their physiological responses to various environmental stressors. The software was designed and implemented in the Microsoft Visual Basic 6.0® Integrated Development Environment."],"dc:format":["application/pdf","4. MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1164666232"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["QRS","volume pulse","QRS detection","heart rate","dZ/dt","blood pressure","respiratory rate"],"dc:title":["IMPLEMENTATION OF INTERACTIVE REMOTE PHYSIOLOGICAL MONITORING AND FEEDBACK TRAINING SYSTEM"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:04Z"}