{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1176684209"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1176684209","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"KINEMATIC COMPARISON OF MARKER SET TECHNIQUES USED IN BIOMECHANICAL ANALYSIS OF THE PITCHING MOTION","abstract":"The purpose of this investigation was to determine if two different reflective marker methods yielded significantly different results when calculating joint centers and kinematic data for collegiate baseball pitchers. Kinematic parameters were calculated at foot contact, ball release, and at three kinematic maximums. The average kinematic variables were determined for each subject and then were combined within each parameter for statistical analysis. Comparison of the two methods was performed using a paired t-test (α = 0.05). Shoulder external rotation at foot contact and maximum shoulder horizontal adduction were the only kinematic parameters that had no significantly different results between the two methods. However, when looking at the individual subject data, there were differences of at least ten degrees for several of the subjects within each parameter. Therefore, the statistical non-significance loses its credibility in the clinical environment. This indicates that the two methods yield significantly different results and should not be used for data comparison.","abstract_html":"The purpose of this investigation was to determine if two different reflective marker methods yielded significantly different results when calculating joint centers and kinematic data for collegiate baseball pitchers. Kinematic parameters were calculated at foot contact, ball release, and at three kinematic maximums. The average kinematic variables were determined for each subject and then were combined within each parameter for statistical analysis. Comparison of the two methods was performed using a paired t-test (α = 0.05). Shoulder external rotation at foot contact and maximum shoulder horizontal adduction were the only kinematic parameters that had no significantly different results between the two methods. However, when looking at the individual subject data, there were differences of at least ten degrees for several of the subjects within each parameter. Therefore, the statistical non-significance loses its credibility in the clinical environment. This indicates that the two methods yield significantly different results and should not be used for data comparison.","abstract_has_math":false,"creators":["Streicher, Matthew C."],"institution":"University of Akron","degree_name":"Master of Science in Engineering","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Verstraete, Mary"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-08-08","date_published":"2007-08-08","updated_at":"2026-11-27T04:13:04Z","subjects":["Engineering, Biomedical","Biomechanics of the pitching motion","Comparison of kinematic quantities","Reflective marker set techniques"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1176684209","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1176684209","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1176684209","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1176684209","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Verstraete, Mary"]},{"key":"dc:creator","label":"Author","values":["Streicher, Matthew C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2007-08-08"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Biomedical","Biomechanics of the pitching motion","Comparison of kinematic quantities","Reflective marker set techniques"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1176684209"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The purpose of this investigation was to determine if two different reflective marker methods yielded significantly different results when calculating joint centers and kinematic data for collegiate baseball pitchers. Kinematic parameters were calculated at foot contact, ball release, and at three kinematic maximums. The average kinematic variables were determined for each subject and then were combined within each parameter for statistical analysis. Comparison of the two methods was performed using a paired t-test (α = 0.05). Shoulder external rotation at foot contact and maximum shoulder horizontal adduction were the only kinematic parameters that had no significantly different results between the two methods. However, when looking at the individual subject data, there were differences of at least ten degrees for several of the subjects within each parameter. Therefore, the statistical non-significance loses its credibility in the clinical environment. This indicates that the two methods yield significantly different results and should not be used for data comparison."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.93","1.15 MB"]},{"key":"dc:title","label":"Title","values":["KINEMATIC COMPARISON OF MARKER SET TECHNIQUES USED IN BIOMECHANICAL ANALYSIS OF THE PITCHING MOTION"]}]}],"canonical_facts":{"dc:contributor.advisor":["Verstraete, Mary"],"dc:creator":["Streicher, Matthew C."],"dc:date":["2007-08-08"],"dc:description":["The purpose of this investigation was to determine if two different reflective marker methods yielded significantly different results when calculating joint centers and kinematic data for collegiate baseball pitchers. Kinematic parameters were calculated at foot contact, ball release, and at three kinematic maximums. The average kinematic variables were determined for each subject and then were combined within each parameter for statistical analysis. Comparison of the two methods was performed using a paired t-test (α = 0.05). Shoulder external rotation at foot contact and maximum shoulder horizontal adduction were the only kinematic parameters that had no significantly different results between the two methods. However, when looking at the individual subject data, there were differences of at least ten degrees for several of the subjects within each parameter. Therefore, the statistical non-significance loses its credibility in the clinical environment. This indicates that the two methods yield significantly different results and should not be used for data comparison."],"dc:format":["application/pdf","p.93","1.15 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1176684209"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Biomedical","Biomechanics of the pitching motion","Comparison of kinematic quantities","Reflective marker set techniques"],"dc:title":["KINEMATIC COMPARISON OF MARKER SET TECHNIQUES USED IN BIOMECHANICAL ANALYSIS OF THE PITCHING MOTION"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:04Z"}