{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1177358316"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1177358316","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A THREE DIMENSIONAL FINITE ELEMENT MODEL TO STUDY THE BIOMECHANICAL AND KINEMATIC CHARACTERISTICS OF THE HUMAN LUMBAR SPINE IN FLEXION","abstract":"The aim of the research was to develop a three-dimensional finite element model to study the biomechanical and kinematic characteristics of the human lumbar spine in flexion. An analytical model of the lumbar spine capable of taking into consideration the actual geometry, non-linear material properties and realistic loading would be of benefit in studying normal biomechanics, as well as in-vivo behavior in injured and surgically altered spines. Fundamental to this approach is an accurate model of the spine. This was achieved by modeling the lumbar segments L2-L4 from Computed Tomography (CT) data and analyzing them under loading conditions that best approximated the human lumbar segments in flexion. An in-vitro study was performed for validation of the finite element model. Human lumbar cadaveric spinal segments (L2-L4) were loaded based on test conditions similar to those defined in the finite element analysis. The results of the cadaver biomechanical study and finite element analysis were compared. The results suggest that the model is a valid approach to assessing the range of motion of the L3 segment under flexion. Rotation under lateral bending moments was additionally investigated to provide a thorough validation of the model.","abstract_html":"The aim of the research was to develop a three-dimensional finite element model to study the biomechanical and kinematic characteristics of the human lumbar spine in flexion. An analytical model of the lumbar spine capable of taking into consideration the actual geometry, non-linear material properties and realistic loading would be of benefit in studying normal biomechanics, as well as in-vivo behavior in injured and surgically altered spines. Fundamental to this approach is an accurate model of the spine. This was achieved by modeling the lumbar segments L2-L4 from Computed Tomography (CT) data and analyzing them under loading conditions that best approximated the human lumbar segments in flexion. An in-vitro study was performed for validation of the finite element model. Human lumbar cadaveric spinal segments (L2-L4) were loaded based on test conditions similar to those defined in the finite element analysis. The results of the cadaver biomechanical study and finite element analysis were compared. The results suggest that the model is a valid approach to assessing the range of motion of the L3 segment under flexion. Rotation under lateral bending moments was additionally investigated to provide a thorough validation of the model.","abstract_has_math":false,"creators":["Mehta, Dhruv Jitesh"],"institution":"University of Akron","degree_name":"Master of Science in Engineering","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Njus, Glen"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-08-08","date_published":"2007-08-08","updated_at":"2026-11-27T04:13:04Z","subjects":["Engineering, Biomedical","FINITE","ELEMENT","BIOMECHANICS","SPINE"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1177358316","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1177358316","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1177358316","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1177358316","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Njus, Glen"]},{"key":"dc:creator","label":"Author","values":["Mehta, Dhruv Jitesh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2007-08-08"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Biomedical","FINITE","ELEMENT","BIOMECHANICS","SPINE"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1177358316"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The aim of the research was to develop a three-dimensional finite element model to study the biomechanical and kinematic characteristics of the human lumbar spine in flexion. An analytical model of the lumbar spine capable of taking into consideration the actual geometry, non-linear material properties and realistic loading would be of benefit in studying normal biomechanics, as well as in-vivo behavior in injured and surgically altered spines. Fundamental to this approach is an accurate model of the spine. This was achieved by modeling the lumbar segments L2-L4 from Computed Tomography (CT) data and analyzing them under loading conditions that best approximated the human lumbar segments in flexion. An in-vitro study was performed for validation of the finite element model. Human lumbar cadaveric spinal segments (L2-L4) were loaded based on test conditions similar to those defined in the finite element analysis. The results of the cadaver biomechanical study and finite element analysis were compared. The results suggest that the model is a valid approach to assessing the range of motion of the L3 segment under flexion. Rotation under lateral bending moments was additionally investigated to provide a thorough validation of the model."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.76","1002.4 KB"]},{"key":"dc:title","label":"Title","values":["A THREE DIMENSIONAL FINITE ELEMENT MODEL TO STUDY THE BIOMECHANICAL AND KINEMATIC CHARACTERISTICS OF THE HUMAN LUMBAR SPINE IN FLEXION"]}]}],"canonical_facts":{"dc:contributor.advisor":["Njus, Glen"],"dc:creator":["Mehta, Dhruv Jitesh"],"dc:date":["2007-08-08"],"dc:description":["The aim of the research was to develop a three-dimensional finite element model to study the biomechanical and kinematic characteristics of the human lumbar spine in flexion. An analytical model of the lumbar spine capable of taking into consideration the actual geometry, non-linear material properties and realistic loading would be of benefit in studying normal biomechanics, as well as in-vivo behavior in injured and surgically altered spines. Fundamental to this approach is an accurate model of the spine. This was achieved by modeling the lumbar segments L2-L4 from Computed Tomography (CT) data and analyzing them under loading conditions that best approximated the human lumbar segments in flexion. An in-vitro study was performed for validation of the finite element model. Human lumbar cadaveric spinal segments (L2-L4) were loaded based on test conditions similar to those defined in the finite element analysis. The results of the cadaver biomechanical study and finite element analysis were compared. The results suggest that the model is a valid approach to assessing the range of motion of the L3 segment under flexion. Rotation under lateral bending moments was additionally investigated to provide a thorough validation of the model."],"dc:format":["application/pdf","p.76","1002.4 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1177358316"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Biomedical","FINITE","ELEMENT","BIOMECHANICS","SPINE"],"dc:title":["A THREE DIMENSIONAL FINITE ELEMENT MODEL TO STUDY THE BIOMECHANICAL AND KINEMATIC CHARACTERISTICS OF THE HUMAN LUMBAR SPINE IN FLEXION"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:04Z"}