{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1204225545"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1204225545","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Image Contrast Enhancement Using Biomolecular Photonic Contrast Agents and Polarimetric Imaging Principles","abstract":"<p>The main purpose of this study is to explore the potential of optical active molecules as molecular contrast agents in increasing the image contrast resolution of biological structures in conjunction with optical polarimetric techniques using a preclinical phantom. The outcome of this study may contribute to enhanced detection of early diseases and pathologies in tissue.</p><p> In this study, a preclinical phantom is designed and experiments were performed using a backscattered polarimetric imaging system. By using the principle of a rotating retarder polarimeter and data reduction algorithm based on polarimetric measurement matrix, Stokes parameters are calculated and finally the DOLP images are calculated. The obtained S0 and DOLP images are fused to get a fused image with higher details. This step is followed for each concentration of optically active molecular contrast agents added to the preclinical phantom. The mean intensities and the signal-to-background ratio are calculated as means to determine the image quality. The results of the experiment showed an increase in image quality parameters with increase in concentration of contrast agents like isopropyl alcohol, sugar solution and salt solution, to the preclinical phantom. It also showed that the DOLP and the fused images are better than S0 images stating that the polarized light yields better output than the total intensity images. This optical polarimetric system in conjunction with the contrast agents can contribute to an effective imaging system for enhanced imaging characteristics. This can help in early detection of tumor present.</p>","abstract_html":"&lt;p&gt;The main purpose of this study is to explore the potential of optical active molecules as molecular contrast agents in increasing the image contrast resolution of biological structures in conjunction with optical polarimetric techniques using a preclinical phantom. The outcome of this study may contribute to enhanced detection of early diseases and pathologies in tissue.&lt;/p&gt;&lt;p&gt; In this study, a preclinical phantom is designed and experiments were performed using a backscattered polarimetric imaging system. By using the principle of a rotating retarder polarimeter and data reduction algorithm based on polarimetric measurement matrix, Stokes parameters are calculated and finally the DOLP images are calculated. The obtained S0 and DOLP images are fused to get a fused image with higher details. This step is followed for each concentration of optically active molecular contrast agents added to the preclinical phantom. The mean intensities and the signal-to-background ratio are calculated as means to determine the image quality. The results of the experiment showed an increase in image quality parameters with increase in concentration of contrast agents like isopropyl alcohol, sugar solution and salt solution, to the preclinical phantom. It also showed that the DOLP and the fused images are better than S0 images stating that the polarized light yields better output than the total intensity images. This optical polarimetric system in conjunction with the contrast agents can contribute to an effective imaging system for enhanced imaging characteristics. This can help in early detection of tumor present.&lt;/p&gt;","abstract_has_math":false,"creators":["Paturi, Sriram Atreya"],"institution":"University of Akron","degree_name":"Master of Science in Engineering","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Giakos, George C."],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-05-12","date_published":"2008-05-12","updated_at":"2026-11-27T04:13:13Z","subjects":["Biomedical Research","Engineering","Optics","Image Enhancement","Contrast Agents","Biophotonics","Degree of Linear Polarization","Polarimetry","Polarization"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1204225545","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1204225545","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1204225545","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1204225545","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Giakos, George C."]},{"key":"dc:creator","label":"Author","values":["Paturi, Sriram Atreya"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-05-12"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Engineering","Optics","Image Enhancement","Contrast Agents","Biophotonics","Degree of Linear Polarization","Polarimetry","Polarization"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1204225545"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>The main purpose of this study is to explore the potential of optical active molecules as molecular contrast agents in increasing the image contrast resolution of biological structures in conjunction with optical polarimetric techniques using a preclinical phantom. The outcome of this study may contribute to enhanced detection of early diseases and pathologies in tissue.</p><p> In this study, a preclinical phantom is designed and experiments were performed using a backscattered polarimetric imaging system. By using the principle of a rotating retarder polarimeter and data reduction algorithm based on polarimetric measurement matrix, Stokes parameters are calculated and finally the DOLP images are calculated. The obtained S0 and DOLP images are fused to get a fused image with higher details. This step is followed for each concentration of optically active molecular contrast agents added to the preclinical phantom. The mean intensities and the signal-to-background ratio are calculated as means to determine the image quality. The results of the experiment showed an increase in image quality parameters with increase in concentration of contrast agents like isopropyl alcohol, sugar solution and salt solution, to the preclinical phantom. It also showed that the DOLP and the fused images are better than S0 images stating that the polarized light yields better output than the total intensity images. This optical polarimetric system in conjunction with the contrast agents can contribute to an effective imaging system for enhanced imaging characteristics. This can help in early detection of tumor present.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.111","1.45 MB"]},{"key":"dc:title","label":"Title","values":["Image Contrast Enhancement Using Biomolecular Photonic Contrast Agents and Polarimetric Imaging Principles"]}]}],"canonical_facts":{"dc:contributor.advisor":["Giakos, George C."],"dc:creator":["Paturi, Sriram Atreya"],"dc:date":["2008-05-12"],"dc:description":["<p>The main purpose of this study is to explore the potential of optical active molecules as molecular contrast agents in increasing the image contrast resolution of biological structures in conjunction with optical polarimetric techniques using a preclinical phantom. The outcome of this study may contribute to enhanced detection of early diseases and pathologies in tissue.</p><p> In this study, a preclinical phantom is designed and experiments were performed using a backscattered polarimetric imaging system. By using the principle of a rotating retarder polarimeter and data reduction algorithm based on polarimetric measurement matrix, Stokes parameters are calculated and finally the DOLP images are calculated. The obtained S0 and DOLP images are fused to get a fused image with higher details. This step is followed for each concentration of optically active molecular contrast agents added to the preclinical phantom. The mean intensities and the signal-to-background ratio are calculated as means to determine the image quality. The results of the experiment showed an increase in image quality parameters with increase in concentration of contrast agents like isopropyl alcohol, sugar solution and salt solution, to the preclinical phantom. It also showed that the DOLP and the fused images are better than S0 images stating that the polarized light yields better output than the total intensity images. This optical polarimetric system in conjunction with the contrast agents can contribute to an effective imaging system for enhanced imaging characteristics. This can help in early detection of tumor present.</p>"],"dc:format":["application/pdf","p.111","1.45 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1204225545"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Engineering","Optics","Image Enhancement","Contrast Agents","Biophotonics","Degree of Linear Polarization","Polarimetry","Polarization"],"dc:title":["Image Contrast Enhancement Using Biomolecular Photonic Contrast Agents and Polarimetric Imaging Principles"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:13Z"}