{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1217029983"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1217029983","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Modeling of Ultracapacitor Short-term and Long-term Dynamic Behavior","abstract":"<p>In this thesis several short-term models and a long-term model have been developed for a NESSCAP3500P ultracapacitor. For the short-term ultracapacitor models, first-, second-, third- and fourth-order transfer functions consistent with an RC ladder model are assumed. The transfer function coefficients are identified by a least squares algorithm based on experimental data consisting of time-varying current excitations and the resulting terminal voltage responses.</p><p>A long-term model with six RC branches is developed by fitting the terminal voltage transient response to an impulse charging current. Hundreds of thousands of terminal voltage data points are recorded and least squares identification is employed to determine the optimal values of the unknown parameters in the long-term model.</p><p>From the ultracapacitor models derived, terminal voltages under different current profiles can be determined accurately over the time frame of one hour with an error less than 0.1 V, the impulse charging and discharging response over a time frame of two months can be simulated with an error less than 0.08 V, and the instantaneous power available can be calculated.</p>","abstract_html":"&lt;p&gt;In this thesis several short-term models and a long-term model have been developed for a NESSCAP3500P ultracapacitor. For the short-term ultracapacitor models, first-, second-, third- and fourth-order transfer functions consistent with an RC ladder model are assumed. The transfer function coefficients are identified by a least squares algorithm based on experimental data consisting of time-varying current excitations and the resulting terminal voltage responses.&lt;/p&gt;&lt;p&gt;A long-term model with six RC branches is developed by fitting the terminal voltage transient response to an impulse charging current. Hundreds of thousands of terminal voltage data points are recorded and least squares identification is employed to determine the optimal values of the unknown parameters in the long-term model.&lt;/p&gt;&lt;p&gt;From the ultracapacitor models derived, terminal voltages under different current profiles can be determined accurately over the time frame of one hour with an error less than 0.1 V, the impulse charging and discharging response over a time frame of two months can be simulated with an error less than 0.08 V, and the instantaneous power available can be calculated.&lt;/p&gt;","abstract_has_math":false,"creators":["Wang, Yang"],"institution":"University of Akron","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Carletta, Joan","Veillette, Robert","Hartley, Tom"],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-09-02","date_published":"2008-09-02","updated_at":"2026-11-27T04:13:13Z","subjects":["Electrical Engineering","Energy","Engineering","Technology","Ultracapacitor model"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1217029983","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1217029983","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1217029983","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1217029983","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Carletta, Joan","Veillette, Robert","Hartley, Tom"]},{"key":"dc:creator","label":"Author","values":["Wang, Yang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-09-02"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering","Energy","Engineering","Technology","Ultracapacitor model"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1217029983"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>In this thesis several short-term models and a long-term model have been developed for a NESSCAP3500P ultracapacitor. For the short-term ultracapacitor models, first-, second-, third- and fourth-order transfer functions consistent with an RC ladder model are assumed. The transfer function coefficients are identified by a least squares algorithm based on experimental data consisting of time-varying current excitations and the resulting terminal voltage responses.</p><p>A long-term model with six RC branches is developed by fitting the terminal voltage transient response to an impulse charging current. Hundreds of thousands of terminal voltage data points are recorded and least squares identification is employed to determine the optimal values of the unknown parameters in the long-term model.</p><p>From the ultracapacitor models derived, terminal voltages under different current profiles can be determined accurately over the time frame of one hour with an error less than 0.1 V, the impulse charging and discharging response over a time frame of two months can be simulated with an error less than 0.08 V, and the instantaneous power available can be calculated.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.91","1.16 MB"]},{"key":"dc:title","label":"Title","values":["Modeling of Ultracapacitor Short-term and Long-term Dynamic Behavior"]}]}],"canonical_facts":{"dc:contributor.advisor":["Carletta, Joan","Veillette, Robert","Hartley, Tom"],"dc:creator":["Wang, Yang"],"dc:date":["2008-09-02"],"dc:description":["<p>In this thesis several short-term models and a long-term model have been developed for a NESSCAP3500P ultracapacitor. For the short-term ultracapacitor models, first-, second-, third- and fourth-order transfer functions consistent with an RC ladder model are assumed. The transfer function coefficients are identified by a least squares algorithm based on experimental data consisting of time-varying current excitations and the resulting terminal voltage responses.</p><p>A long-term model with six RC branches is developed by fitting the terminal voltage transient response to an impulse charging current. Hundreds of thousands of terminal voltage data points are recorded and least squares identification is employed to determine the optimal values of the unknown parameters in the long-term model.</p><p>From the ultracapacitor models derived, terminal voltages under different current profiles can be determined accurately over the time frame of one hour with an error less than 0.1 V, the impulse charging and discharging response over a time frame of two months can be simulated with an error less than 0.08 V, and the instantaneous power available can be calculated.</p>"],"dc:format":["application/pdf","p.91","1.16 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1217029983"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Electrical Engineering","Energy","Engineering","Technology","Ultracapacitor model"],"dc:title":["Modeling of Ultracapacitor Short-term and Long-term Dynamic Behavior"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:13Z"}