{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1218171143"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1218171143","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Three Dimensional Modeling of Hard Connective Tissues Using a Laser Displacement Sensor","abstract":"In the field of biomechanics, Finite Element (FE) Analysis is a popular technique for calculating stress, strain and deformations of bony structures. FE modeling consists of simulating biomechanical testing on computer models, which represents the structure of interest in terms of cross-sectional area, material properties etc.To obtain a FE Model, the 3D coordinates of the structure in 3D space are required. A common method of obtaining the coordinates of a structure is from its CT /MRI scan image. Using commercially available software, 2D CT/MRI images are reconstructed to give a 3D model. However, these techniques are time consuming, expensive and prone to user errors. The goal of this study was to employ a new method for 3D scanning and reconstruction of hard tissues. Here, a displacement laser sensor was used for 3D scanning of a bone structure and a FE model was obtained for the same.The laser sensor had an accuracy of ± 0.1mm, was relatively inexpensive and once the assembly was designed, any number of specimens could be scanned. This technique drastically reduces the time and cost as compared to current conventional techniques.","abstract_html":"In the field of biomechanics, Finite Element (FE) Analysis is a popular technique for calculating stress, strain and deformations of bony structures. FE modeling consists of simulating biomechanical testing on computer models, which represents the structure of interest in terms of cross-sectional area, material properties etc.To obtain a FE Model, the 3D coordinates of the structure in 3D space are required. A common method of obtaining the coordinates of a structure is from its CT /MRI scan image. Using commercially available software, 2D CT/MRI images are reconstructed to give a 3D model. However, these techniques are time consuming, expensive and prone to user errors. The goal of this study was to employ a new method for 3D scanning and reconstruction of hard tissues. Here, a displacement laser sensor was used for 3D scanning of a bone structure and a FE model was obtained for the same.The laser sensor had an accuracy of ± 0.1mm, was relatively inexpensive and once the assembly was designed, any number of specimens could be scanned. This technique drastically reduces the time and cost as compared to current conventional techniques.","abstract_has_math":false,"creators":["Kanabar, Prachi"],"institution":"University of Akron","degree_name":"Master of Science in Engineering","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Njus, Glen"],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-09-02","date_published":"2008-09-02","updated_at":"2026-11-27T04:13:13Z","subjects":["Biomedical Research","three dimensional modeling","laser displacement sensor"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1218171143","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1218171143","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1218171143","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1218171143","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Njus, Glen"]},{"key":"dc:creator","label":"Author","values":["Kanabar, Prachi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-09-02"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","three dimensional modeling","laser displacement sensor"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1218171143"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In the field of biomechanics, Finite Element (FE) Analysis is a popular technique for calculating stress, strain and deformations of bony structures. FE modeling consists of simulating biomechanical testing on computer models, which represents the structure of interest in terms of cross-sectional area, material properties etc.To obtain a FE Model, the 3D coordinates of the structure in 3D space are required. A common method of obtaining the coordinates of a structure is from its CT /MRI scan image. Using commercially available software, 2D CT/MRI images are reconstructed to give a 3D model. However, these techniques are time consuming, expensive and prone to user errors. The goal of this study was to employ a new method for 3D scanning and reconstruction of hard tissues. Here, a displacement laser sensor was used for 3D scanning of a bone structure and a FE model was obtained for the same.The laser sensor had an accuracy of ± 0.1mm, was relatively inexpensive and once the assembly was designed, any number of specimens could be scanned. This technique drastically reduces the time and cost as compared to current conventional techniques."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1.99 MB"]},{"key":"dc:title","label":"Title","values":["Three Dimensional Modeling of Hard Connective Tissues Using a Laser Displacement Sensor"]}]}],"canonical_facts":{"dc:contributor.advisor":["Njus, Glen"],"dc:creator":["Kanabar, Prachi"],"dc:date":["2008-09-02"],"dc:description":["In the field of biomechanics, Finite Element (FE) Analysis is a popular technique for calculating stress, strain and deformations of bony structures. FE modeling consists of simulating biomechanical testing on computer models, which represents the structure of interest in terms of cross-sectional area, material properties etc.To obtain a FE Model, the 3D coordinates of the structure in 3D space are required. A common method of obtaining the coordinates of a structure is from its CT /MRI scan image. Using commercially available software, 2D CT/MRI images are reconstructed to give a 3D model. However, these techniques are time consuming, expensive and prone to user errors. The goal of this study was to employ a new method for 3D scanning and reconstruction of hard tissues. Here, a displacement laser sensor was used for 3D scanning of a bone structure and a FE model was obtained for the same.The laser sensor had an accuracy of ± 0.1mm, was relatively inexpensive and once the assembly was designed, any number of specimens could be scanned. This technique drastically reduces the time and cost as compared to current conventional techniques."],"dc:format":["application/pdf","1.99 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1218171143"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","three dimensional modeling","laser displacement sensor"],"dc:title":["Three Dimensional Modeling of Hard Connective Tissues Using a Laser Displacement Sensor"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:13Z"}