{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1240858653"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1240858653","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Modeling of Ion Transport for Micro/Nano Size Particles in Coulter Counter Application","abstract":"Coulter Counter (CC) is a device for counting small particles by recording the electrical current change during the translocation of the particle through a small pore. By counting the number of pulses in the measured current signal, the number of particles in the solution can be determined. The size and translocation time can also be deducted from the magnitude and duration of the pulses. In order to produce measurable current change, only particles of comparable sizes with the pore can be characterized, however. With rapid development of present micro/nano-fabrication technologies, CC is now widely used to characterize various micro/nano size particles, including small molecules, proteins, and even DNA. This thesis presents an electrical model and a comprehensive multi-physical model of ion transport in CC. The electrical model represents the classical theory of CC. From this model, the off-center effect and particle shape effect were further explored for which analytical results are not available. The multi-physical model involves a coupled system of the Navier-Stokes equation for flow field, the Nernst-Planck equation for electrolyte ion transport, and the Poisson equation for electrical field. The model is used to simulate the electrolyte flow with a surface charged particle in a nano-channel, representing the core part of CC. 2D axial symmetric system is used to reduce the computational time. The model predicts the flow and electric fields as well as the distribution of the ion concentrations in the channel. The effects on electric current through the channel are then investigated by systematically varying the particle surface charge, size, and electrolyte concentration. The Electrical Double Layer polarization under electrical and pressure fields was also investigated. Different patterns of polarization were found and compared.","abstract_html":"Coulter Counter (CC) is a device for counting small particles by recording the electrical current change during the translocation of the particle through a small pore. By counting the number of pulses in the measured current signal, the number of particles in the solution can be determined. The size and translocation time can also be deducted from the magnitude and duration of the pulses. In order to produce measurable current change, only particles of comparable sizes with the pore can be characterized, however. With rapid development of present micro/nano-fabrication technologies, CC is now widely used to characterize various micro/nano size particles, including small molecules, proteins, and even DNA. This thesis presents an electrical model and a comprehensive multi-physical model of ion transport in CC. The electrical model represents the classical theory of CC. From this model, the off-center effect and particle shape effect were further explored for which analytical results are not available. The multi-physical model involves a coupled system of the Navier-Stokes equation for flow field, the Nernst-Planck equation for electrolyte ion transport, and the Poisson equation for electrical field. The model is used to simulate the electrolyte flow with a surface charged particle in a nano-channel, representing the core part of CC. 2D axial symmetric system is used to reduce the computational time. The model predicts the flow and electric fields as well as the distribution of the ion concentrations in the channel. The effects on electric current through the channel are then investigated by systematically varying the particle surface charge, size, and electrolyte concentration. The Electrical Double Layer polarization under electrical and pressure fields was also investigated. Different patterns of polarization were found and compared.","abstract_has_math":false,"creators":["Qin, Zhenpeng"],"institution":"University of Akron","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Wang, Guo-Xiang"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-06-09","date_published":"2009-06-09","updated_at":"2026-11-26T03:12:05Z","subjects":["Mechanical Engineering","Coulter Counter","Resistive Pulse Sensor","Ion transport","Multi-physical simulation","Electrical Double Layer","Ionic current"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1240858653","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1240858653","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1240858653","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1240858653","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Wang, Guo-Xiang"]},{"key":"dc:creator","label":"Author","values":["Qin, Zhenpeng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009-06-09"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","Coulter Counter","Resistive Pulse Sensor","Ion transport","Multi-physical simulation","Electrical Double Layer","Ionic current"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1240858653"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Coulter Counter (CC) is a device for counting small particles by recording the electrical current change during the translocation of the particle through a small pore. By counting the number of pulses in the measured current signal, the number of particles in the solution can be determined. The size and translocation time can also be deducted from the magnitude and duration of the pulses. In order to produce measurable current change, only particles of comparable sizes with the pore can be characterized, however. With rapid development of present micro/nano-fabrication technologies, CC is now widely used to characterize various micro/nano size particles, including small molecules, proteins, and even DNA. This thesis presents an electrical model and a comprehensive multi-physical model of ion transport in CC. The electrical model represents the classical theory of CC. From this model, the off-center effect and particle shape effect were further explored for which analytical results are not available. The multi-physical model involves a coupled system of the Navier-Stokes equation for flow field, the Nernst-Planck equation for electrolyte ion transport, and the Poisson equation for electrical field. The model is used to simulate the electrolyte flow with a surface charged particle in a nano-channel, representing the core part of CC. 2D axial symmetric system is used to reduce the computational time. The model predicts the flow and electric fields as well as the distribution of the ion concentrations in the channel. The effects on electric current through the channel are then investigated by systematically varying the particle surface charge, size, and electrolyte concentration. The Electrical Double Layer polarization under electrical and pressure fields was also investigated. Different patterns of polarization were found and compared."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.81","1.59 MB"]},{"key":"dc:title","label":"Title","values":["Modeling of Ion Transport for Micro/Nano Size Particles in Coulter Counter Application"]}]}],"canonical_facts":{"dc:contributor":["Wang, Guo-Xiang"],"dc:creator":["Qin, Zhenpeng"],"dc:date":["2009-06-09"],"dc:description":["Coulter Counter (CC) is a device for counting small particles by recording the electrical current change during the translocation of the particle through a small pore. By counting the number of pulses in the measured current signal, the number of particles in the solution can be determined. The size and translocation time can also be deducted from the magnitude and duration of the pulses. In order to produce measurable current change, only particles of comparable sizes with the pore can be characterized, however. With rapid development of present micro/nano-fabrication technologies, CC is now widely used to characterize various micro/nano size particles, including small molecules, proteins, and even DNA. This thesis presents an electrical model and a comprehensive multi-physical model of ion transport in CC. The electrical model represents the classical theory of CC. From this model, the off-center effect and particle shape effect were further explored for which analytical results are not available. The multi-physical model involves a coupled system of the Navier-Stokes equation for flow field, the Nernst-Planck equation for electrolyte ion transport, and the Poisson equation for electrical field. The model is used to simulate the electrolyte flow with a surface charged particle in a nano-channel, representing the core part of CC. 2D axial symmetric system is used to reduce the computational time. The model predicts the flow and electric fields as well as the distribution of the ion concentrations in the channel. The effects on electric current through the channel are then investigated by systematically varying the particle surface charge, size, and electrolyte concentration. The Electrical Double Layer polarization under electrical and pressure fields was also investigated. Different patterns of polarization were found and compared."],"dc:format":["application/pdf","p.81","1.59 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1240858653"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","Coulter Counter","Resistive Pulse Sensor","Ion transport","Multi-physical simulation","Electrical Double Layer","Ionic current"],"dc:title":["Modeling of Ion Transport for Micro/Nano Size Particles in Coulter Counter Application"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-26T03:12:05Z"}