{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1248115447"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1248115447","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"X-Ray Photoelectron Spectroscopy Studies of Orthopedic Materials","abstract":"<p>Knee replacement surgery is a potential option to relieve symptoms for those afflicted by arthritis. However, the materials introduced into the body may produce wear debris which can lead to inflammation of the surrounding tissue and sometimes require replacement of the implant. To better understand the mechanism behind the generation of this wear debris and ultimately the failure of the implant, one of our goals is to determine the composition of the wear debris.</p><p>We test for the presence of metals in samples taken from synovial fluid using X-ray Photoelectron Spectroscopy, Scanning Electron Microscopy, and Energy Dispersive X-ray Spectrometry. We also test for bacterial adhesion to various zirconium alloys with X-Ray Photoelectron Spectroscopy as a means of determining the biocompatibility of these materials which are now being used as alternatives for the more common CoCrMo and Ti6Al4V orthopedic alloys.</p>","abstract_html":"&lt;p&gt;Knee replacement surgery is a potential option to relieve symptoms for those afflicted by arthritis. However, the materials introduced into the body may produce wear debris which can lead to inflammation of the surrounding tissue and sometimes require replacement of the implant. To better understand the mechanism behind the generation of this wear debris and ultimately the failure of the implant, one of our goals is to determine the composition of the wear debris.&lt;/p&gt;&lt;p&gt;We test for the presence of metals in samples taken from synovial fluid using X-ray Photoelectron Spectroscopy, Scanning Electron Microscopy, and Energy Dispersive X-ray Spectrometry. We also test for bacterial adhesion to various zirconium alloys with X-Ray Photoelectron Spectroscopy as a means of determining the biocompatibility of these materials which are now being used as alternatives for the more common CoCrMo and Ti6Al4V orthopedic alloys.&lt;/p&gt;","abstract_has_math":false,"creators":["Ehrman, James D."],"institution":"University of Akron","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":["Ramsier, Rex"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-10-05","date_published":"2009-10-05","updated_at":"2026-11-27T04:13:13Z","subjects":["Biomedical Research","Biophysics","Health","Health Care","Physics","XPS","SEM","EDS","CoCrMo","TiAlV","Ti6Al4V","synovial","TKR","total knee replacement","knee debris","microbial adhesion","zirconium alloys"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1248115447","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1248115447","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1248115447","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1248115447","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ramsier, Rex"]},{"key":"dc:creator","label":"Author","values":["Ehrman, James D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009-10-05"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Biophysics","Health","Health Care","Physics","XPS","SEM","EDS","CoCrMo","TiAlV","Ti6Al4V","synovial","TKR","total knee replacement","knee debris","microbial adhesion","zirconium alloys"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1248115447"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Knee replacement surgery is a potential option to relieve symptoms for those afflicted by arthritis. However, the materials introduced into the body may produce wear debris which can lead to inflammation of the surrounding tissue and sometimes require replacement of the implant. To better understand the mechanism behind the generation of this wear debris and ultimately the failure of the implant, one of our goals is to determine the composition of the wear debris.</p><p>We test for the presence of metals in samples taken from synovial fluid using X-ray Photoelectron Spectroscopy, Scanning Electron Microscopy, and Energy Dispersive X-ray Spectrometry. We also test for bacterial adhesion to various zirconium alloys with X-Ray Photoelectron Spectroscopy as a means of determining the biocompatibility of these materials which are now being used as alternatives for the more common CoCrMo and Ti6Al4V orthopedic alloys.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.48","810. KB"]},{"key":"dc:title","label":"Title","values":["X-Ray Photoelectron Spectroscopy Studies of Orthopedic Materials"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ramsier, Rex"],"dc:creator":["Ehrman, James D."],"dc:date":["2009-10-05"],"dc:description":["<p>Knee replacement surgery is a potential option to relieve symptoms for those afflicted by arthritis. However, the materials introduced into the body may produce wear debris which can lead to inflammation of the surrounding tissue and sometimes require replacement of the implant. To better understand the mechanism behind the generation of this wear debris and ultimately the failure of the implant, one of our goals is to determine the composition of the wear debris.</p><p>We test for the presence of metals in samples taken from synovial fluid using X-ray Photoelectron Spectroscopy, Scanning Electron Microscopy, and Energy Dispersive X-ray Spectrometry. We also test for bacterial adhesion to various zirconium alloys with X-Ray Photoelectron Spectroscopy as a means of determining the biocompatibility of these materials which are now being used as alternatives for the more common CoCrMo and Ti6Al4V orthopedic alloys.</p>"],"dc:format":["application/pdf","p.48","810. KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1248115447"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Biophysics","Health","Health Care","Physics","XPS","SEM","EDS","CoCrMo","TiAlV","Ti6Al4V","synovial","TKR","total knee replacement","knee debris","microbial adhesion","zirconium alloys"],"dc:title":["X-Ray Photoelectron Spectroscopy Studies of Orthopedic Materials"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:13Z"}