{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1269252194"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1269252194","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Design, Development, Testing, and Evaluation of a Prosthetic Venous Valve","abstract":"<p>Chronic Venous Insufficiency (CVI) comes about when the veins in the legs are not able to return blood to the heart effectively. The major cause of this is when functioning of venous valves is compromised. When vein valves become incompetent, their one directional flow restriction is compromised and there is leakage in the wrong (retrograde) direction, which pools in the legs and feet of the patient leading to varicose veins, heavy legs, discoloration, pain and ulcers. This affects about 24 million Americans with costs to society both direct and indirect estimated to be about $1 billion in the United States.</p><p>The goal of this project was to create a valve design that is capable of closing and sealing to prevent retrograde flow. The newly designed valve was tested in simulated standing and supine positions for breathing and ankle flexion conditions. Parameters obtained were pressure, resistance, reflux, work and efficiency. The results obtained indicated that the new design improved on the performance of previous design quantitatively and well as qualitatively.</p>","abstract_html":"&lt;p&gt;Chronic Venous Insufficiency (CVI) comes about when the veins in the legs are not able to return blood to the heart effectively. The major cause of this is when functioning of venous valves is compromised. When vein valves become incompetent, their one directional flow restriction is compromised and there is leakage in the wrong (retrograde) direction, which pools in the legs and feet of the patient leading to varicose veins, heavy legs, discoloration, pain and ulcers. This affects about 24 million Americans with costs to society both direct and indirect estimated to be about $1 billion in the United States.&lt;/p&gt;&lt;p&gt;The goal of this project was to create a valve design that is capable of closing and sealing to prevent retrograde flow. The newly designed valve was tested in simulated standing and supine positions for breathing and ankle flexion conditions. Parameters obtained were pressure, resistance, reflux, work and efficiency. The results obtained indicated that the new design improved on the performance of previous design quantitatively and well as qualitatively.&lt;/p&gt;","abstract_has_math":false,"creators":["Anim, Kwaku"],"institution":"University of Akron","degree_name":"Master of Science in Engineering","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Rittgers, Stanley"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-05-21","date_published":"2010-05-21","updated_at":"2026-11-27T04:13:19Z","subjects":["Biomedical Research","Engineering","Fluid Dynamics","Prosthetic Venous Valve","Chronic Venous Insufficiency","pressure-flow","muscle pump","vein valve","sylgard molding","calf muscle pump","artificial valve","valve design"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1269252194","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1269252194","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1269252194","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1269252194","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Rittgers, Stanley"]},{"key":"dc:creator","label":"Author","values":["Anim, Kwaku"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-05-21"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Engineering","Fluid Dynamics","Prosthetic Venous Valve","Chronic Venous Insufficiency","pressure-flow","muscle pump","vein valve","sylgard molding","calf muscle pump","artificial valve","valve design"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1269252194"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Chronic Venous Insufficiency (CVI) comes about when the veins in the legs are not able to return blood to the heart effectively. The major cause of this is when functioning of venous valves is compromised. When vein valves become incompetent, their one directional flow restriction is compromised and there is leakage in the wrong (retrograde) direction, which pools in the legs and feet of the patient leading to varicose veins, heavy legs, discoloration, pain and ulcers. This affects about 24 million Americans with costs to society both direct and indirect estimated to be about $1 billion in the United States.</p><p>The goal of this project was to create a valve design that is capable of closing and sealing to prevent retrograde flow. The newly designed valve was tested in simulated standing and supine positions for breathing and ankle flexion conditions. Parameters obtained were pressure, resistance, reflux, work and efficiency. The results obtained indicated that the new design improved on the performance of previous design quantitatively and well as qualitatively.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","2.68 MB"]},{"key":"dc:title","label":"Title","values":["Design, Development, Testing, and Evaluation of a Prosthetic Venous Valve"]}]}],"canonical_facts":{"dc:contributor.advisor":["Rittgers, Stanley"],"dc:creator":["Anim, Kwaku"],"dc:date":["2010-05-21"],"dc:description":["<p>Chronic Venous Insufficiency (CVI) comes about when the veins in the legs are not able to return blood to the heart effectively. The major cause of this is when functioning of venous valves is compromised. When vein valves become incompetent, their one directional flow restriction is compromised and there is leakage in the wrong (retrograde) direction, which pools in the legs and feet of the patient leading to varicose veins, heavy legs, discoloration, pain and ulcers. This affects about 24 million Americans with costs to society both direct and indirect estimated to be about $1 billion in the United States.</p><p>The goal of this project was to create a valve design that is capable of closing and sealing to prevent retrograde flow. The newly designed valve was tested in simulated standing and supine positions for breathing and ankle flexion conditions. Parameters obtained were pressure, resistance, reflux, work and efficiency. The results obtained indicated that the new design improved on the performance of previous design quantitatively and well as qualitatively.</p>"],"dc:format":["application/pdf","2.68 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1269252194"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Engineering","Fluid Dynamics","Prosthetic Venous Valve","Chronic Venous Insufficiency","pressure-flow","muscle pump","vein valve","sylgard molding","calf muscle pump","artificial valve","valve design"],"dc:title":["Design, Development, Testing, and Evaluation of a Prosthetic Venous Valve"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:19Z"}