{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1278707573"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1278707573","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"In-vitro Biomechanical Evaluation of Multiple Freeze-Thaw Cycles on 3D Kinematics of Human Cadaveric Lumbar Spine","abstract":"<p>In-vitro biomechanical evaluations are often carried out with fresh frozen cadaveric spine specimens in order to determine the post-operative kinematics of spinal motion segments with novel spinal implants or surgical techniques. Such biomechanical studies commonly involve repeated tests with the spinal specimen in the intact state, followed by an injured state and one or more instrumented states. Previous studies have measured changes in mechanical properties of a spinal motion segment after a single occurrence of freezing, but the effect of multiple freeze–thaw cycles have not been reported.</p><p>In the current study, flexibility tests in flexion-extension (FE), lateral bending (LB), axial rotation (AR), and FE with 660 N of compressive load (FE+FL), were repeatedly carried out on a human cadaveric multi-segmented lumbosacral specimen (L3-Sacrum) on 8 separate test days, with freeze-thaw cycles between test days, and 8 sets of flexibility tests were carried out within each test day. A custom-built flexibility testing machine was used to apply 5 continuous cycles of pure bending moment up to ± 7.5 Nm at a rate of about 1°/s while ensuring that the specimen’s motion remained unconstrained. An optoelectronic camera system (NDI Optotrak Certus) was used to capture the 3-D kinematics of L3, L4, L5 and the Sacrum. The load-displacement data at the last loading cycle were analyzed to determine the range of motion (ROM) and neutral zone (NZ).</p><p> A significant difference, in the specimen’s total ROM and NZ across L3-Sacrum, was found between test days in all loading directions (all p<0.001) using one-way repeated measures ANOVA. There were no within-day variations in the ROM or NZ in FE (p=0.87, p=0.98), LB (p=0.83, p=0.86), AR (p=0.60, p=0.94), and FE+FL (p=0.69, p=0.84) as determined from the Wilcoxon Signed Rank test. The inter-segmental ROM and NZ data for L3-L4, L4-L5, and L5-Sacrum also showed significant differences between test days and negligible intra-day variations using the above mentioned statistical tests.</p><p>The current study showed that ROM and NZ of human cadaveric lumbosacral spinal segments were significantly affected by multiple freeze-thaw cycles but were not significantly different within a 12 hour test day. The results indicated that in-vitro biomechanical experiments with comparison between sequential states on a test specimen should be conducted within a test session.</p>","abstract_html":"&lt;p&gt;In-vitro biomechanical evaluations are often carried out with fresh frozen cadaveric spine specimens in order to determine the post-operative kinematics of spinal motion segments with novel spinal implants or surgical techniques. Such biomechanical studies commonly involve repeated tests with the spinal specimen in the intact state, followed by an injured state and one or more instrumented states. Previous studies have measured changes in mechanical properties of a spinal motion segment after a single occurrence of freezing, but the effect of multiple freeze–thaw cycles have not been reported.&lt;/p&gt;&lt;p&gt;In the current study, flexibility tests in flexion-extension (FE), lateral bending (LB), axial rotation (AR), and FE with 660 N of compressive load (FE+FL), were repeatedly carried out on a human cadaveric multi-segmented lumbosacral specimen (L3-Sacrum) on 8 separate test days, with freeze-thaw cycles between test days, and 8 sets of flexibility tests were carried out within each test day. A custom-built flexibility testing machine was used to apply 5 continuous cycles of pure bending moment up to ± 7.5 Nm at a rate of about 1°/s while ensuring that the specimen’s motion remained unconstrained. An optoelectronic camera system (NDI Optotrak Certus) was used to capture the 3-D kinematics of L3, L4, L5 and the Sacrum. The load-displacement data at the last loading cycle were analyzed to determine the range of motion (ROM) and neutral zone (NZ).&lt;/p&gt;&lt;p&gt; A significant difference, in the specimen’s total ROM and NZ across L3-Sacrum, was found between test days in all loading directions (all p&lt;0.001) using one-way repeated measures ANOVA. There were no within-day variations in the ROM or NZ in FE (p=0.87, p=0.98), LB (p=0.83, p=0.86), AR (p=0.60, p=0.94), and FE+FL (p=0.69, p=0.84) as determined from the Wilcoxon Signed Rank test. The inter-segmental ROM and NZ data for L3-L4, L4-L5, and L5-Sacrum also showed significant differences between test days and negligible intra-day variations using the above mentioned statistical tests.&lt;/p&gt;&lt;p&gt;The current study showed that ROM and NZ of human cadaveric lumbosacral spinal segments were significantly affected by multiple freeze-thaw cycles but were not significantly different within a 12 hour test day. The results indicated that in-vitro biomechanical experiments with comparison between sequential states on a test specimen should be conducted within a test session.&lt;/p&gt;","abstract_has_math":false,"creators":["Uppuganti, Sasidhar"],"institution":"University of Akron","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Tan, Juay Seng"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-08-26","date_published":"2010-08-26","updated_at":"2026-11-27T04:13:19Z","subjects":["Biomedical Research","Design","Engineering","Experiments","Mechanics","Statistics","Lumbar Spine","In-Vitro Testing","Biomechanics","Orthopaedic Biomechanics","Spine Kinematics"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1278707573","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1278707573","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1278707573","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1278707573","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Tan, Juay Seng"]},{"key":"dc:creator","label":"Author","values":["Uppuganti, Sasidhar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-08-26"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Design","Engineering","Experiments","Mechanics","Statistics","Lumbar Spine","In-Vitro Testing","Biomechanics","Orthopaedic Biomechanics","Spine Kinematics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1278707573"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>In-vitro biomechanical evaluations are often carried out with fresh frozen cadaveric spine specimens in order to determine the post-operative kinematics of spinal motion segments with novel spinal implants or surgical techniques. Such biomechanical studies commonly involve repeated tests with the spinal specimen in the intact state, followed by an injured state and one or more instrumented states. Previous studies have measured changes in mechanical properties of a spinal motion segment after a single occurrence of freezing, but the effect of multiple freeze–thaw cycles have not been reported.</p><p>In the current study, flexibility tests in flexion-extension (FE), lateral bending (LB), axial rotation (AR), and FE with 660 N of compressive load (FE+FL), were repeatedly carried out on a human cadaveric multi-segmented lumbosacral specimen (L3-Sacrum) on 8 separate test days, with freeze-thaw cycles between test days, and 8 sets of flexibility tests were carried out within each test day. A custom-built flexibility testing machine was used to apply 5 continuous cycles of pure bending moment up to ± 7.5 Nm at a rate of about 1°/s while ensuring that the specimen’s motion remained unconstrained. An optoelectronic camera system (NDI Optotrak Certus) was used to capture the 3-D kinematics of L3, L4, L5 and the Sacrum. The load-displacement data at the last loading cycle were analyzed to determine the range of motion (ROM) and neutral zone (NZ).</p><p> A significant difference, in the specimen’s total ROM and NZ across L3-Sacrum, was found between test days in all loading directions (all p<0.001) using one-way repeated measures ANOVA. There were no within-day variations in the ROM or NZ in FE (p=0.87, p=0.98), LB (p=0.83, p=0.86), AR (p=0.60, p=0.94), and FE+FL (p=0.69, p=0.84) as determined from the Wilcoxon Signed Rank test. The inter-segmental ROM and NZ data for L3-L4, L4-L5, and L5-Sacrum also showed significant differences between test days and negligible intra-day variations using the above mentioned statistical tests.</p><p>The current study showed that ROM and NZ of human cadaveric lumbosacral spinal segments were significantly affected by multiple freeze-thaw cycles but were not significantly different within a 12 hour test day. The results indicated that in-vitro biomechanical experiments with comparison between sequential states on a test specimen should be conducted within a test session.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.149","7.83 MB"]},{"key":"dc:title","label":"Title","values":["In-vitro Biomechanical Evaluation of Multiple Freeze-Thaw Cycles on 3D Kinematics of Human Cadaveric Lumbar Spine"]}]}],"canonical_facts":{"dc:contributor.advisor":["Tan, Juay Seng"],"dc:creator":["Uppuganti, Sasidhar"],"dc:date":["2010-08-26"],"dc:description":["<p>In-vitro biomechanical evaluations are often carried out with fresh frozen cadaveric spine specimens in order to determine the post-operative kinematics of spinal motion segments with novel spinal implants or surgical techniques. Such biomechanical studies commonly involve repeated tests with the spinal specimen in the intact state, followed by an injured state and one or more instrumented states. Previous studies have measured changes in mechanical properties of a spinal motion segment after a single occurrence of freezing, but the effect of multiple freeze–thaw cycles have not been reported.</p><p>In the current study, flexibility tests in flexion-extension (FE), lateral bending (LB), axial rotation (AR), and FE with 660 N of compressive load (FE+FL), were repeatedly carried out on a human cadaveric multi-segmented lumbosacral specimen (L3-Sacrum) on 8 separate test days, with freeze-thaw cycles between test days, and 8 sets of flexibility tests were carried out within each test day. A custom-built flexibility testing machine was used to apply 5 continuous cycles of pure bending moment up to ± 7.5 Nm at a rate of about 1°/s while ensuring that the specimen’s motion remained unconstrained. An optoelectronic camera system (NDI Optotrak Certus) was used to capture the 3-D kinematics of L3, L4, L5 and the Sacrum. The load-displacement data at the last loading cycle were analyzed to determine the range of motion (ROM) and neutral zone (NZ).</p><p> A significant difference, in the specimen’s total ROM and NZ across L3-Sacrum, was found between test days in all loading directions (all p<0.001) using one-way repeated measures ANOVA. There were no within-day variations in the ROM or NZ in FE (p=0.87, p=0.98), LB (p=0.83, p=0.86), AR (p=0.60, p=0.94), and FE+FL (p=0.69, p=0.84) as determined from the Wilcoxon Signed Rank test. The inter-segmental ROM and NZ data for L3-L4, L4-L5, and L5-Sacrum also showed significant differences between test days and negligible intra-day variations using the above mentioned statistical tests.</p><p>The current study showed that ROM and NZ of human cadaveric lumbosacral spinal segments were significantly affected by multiple freeze-thaw cycles but were not significantly different within a 12 hour test day. The results indicated that in-vitro biomechanical experiments with comparison between sequential states on a test specimen should be conducted within a test session.</p>"],"dc:format":["application/pdf","p.149","7.83 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1278707573"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Design","Engineering","Experiments","Mechanics","Statistics","Lumbar Spine","In-Vitro Testing","Biomechanics","Orthopaedic Biomechanics","Spine Kinematics"],"dc:title":["In-vitro Biomechanical Evaluation of Multiple Freeze-Thaw Cycles on 3D Kinematics of Human Cadaveric Lumbar Spine"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:19Z"}