{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1279115371"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1279115371","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Permeation Sampling of BTEX and Gasoline","abstract":"A method for solventless extraction and determination of gasoline components in water has been developed. This method uses silicone polycarbonate permeation membranes to extract the components, and collect them on a Tenax TA adsorbent. Samples were thermally desorbed into a gas chromatograph with flame ionization detection for separation and determination of the components. Time-weighted average (TWA) concentrations were determined by plotting the amount of analyte collected versus the product of concentration and time (ppb•hr). A linear response was seen in the TWA curves for benzene, toluene, ethylbenzene and the three isomers of xylene (BTEX). These components had detection limits from 1.4 ppb for m- and p-xylene to 2.7 ppb for toluene. The effects of temperature and common environmental contaminants were examined. The advantages of this method include being environmentally friendly due to the lack of solvent and having less steps for analysis than many standard methods.","abstract_html":"A method for solventless extraction and determination of gasoline components in water has been developed. This method uses silicone polycarbonate permeation membranes to extract the components, and collect them on a Tenax TA adsorbent. Samples were thermally desorbed into a gas chromatograph with flame ionization detection for separation and determination of the components. Time-weighted average (TWA) concentrations were determined by plotting the amount of analyte collected versus the product of concentration and time (ppb•hr). A linear response was seen in the TWA curves for benzene, toluene, ethylbenzene and the three isomers of xylene (BTEX). These components had detection limits from 1.4 ppb for m- and p-xylene to 2.7 ppb for toluene. The effects of temperature and common environmental contaminants were examined. The advantages of this method include being environmentally friendly due to the lack of solvent and having less steps for analysis than many standard methods.","abstract_has_math":false,"creators":["Anderson, Cody Allen"],"institution":"University of Akron","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":["Hardy, James"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-08-18","date_published":"2010-08-18","updated_at":"2026-11-27T04:13:19Z","subjects":["Analytical Chemistry","Chemistry","Environmental Science","Experiments","BTEX","water","benzene","toluene","ethylbenzene","xylene","permeation","membrane","GC","gas chromatography","thermal desorption"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1279115371","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1279115371","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1279115371","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1279115371","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hardy, James"]},{"key":"dc:creator","label":"Author","values":["Anderson, Cody Allen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-08-18"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Analytical Chemistry","Chemistry","Environmental Science","Experiments","BTEX","water","benzene","toluene","ethylbenzene","xylene","permeation","membrane","GC","gas chromatography","thermal desorption"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1279115371"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A method for solventless extraction and determination of gasoline components in water has been developed. This method uses silicone polycarbonate permeation membranes to extract the components, and collect them on a Tenax TA adsorbent. Samples were thermally desorbed into a gas chromatograph with flame ionization detection for separation and determination of the components. Time-weighted average (TWA) concentrations were determined by plotting the amount of analyte collected versus the product of concentration and time (ppb•hr). A linear response was seen in the TWA curves for benzene, toluene, ethylbenzene and the three isomers of xylene (BTEX). These components had detection limits from 1.4 ppb for m- and p-xylene to 2.7 ppb for toluene. The effects of temperature and common environmental contaminants were examined. The advantages of this method include being environmentally friendly due to the lack of solvent and having less steps for analysis than many standard methods."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","434.9 KB"]},{"key":"dc:title","label":"Title","values":["Permeation Sampling of BTEX and Gasoline"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hardy, James"],"dc:creator":["Anderson, Cody Allen"],"dc:date":["2010-08-18"],"dc:description":["A method for solventless extraction and determination of gasoline components in water has been developed. This method uses silicone polycarbonate permeation membranes to extract the components, and collect them on a Tenax TA adsorbent. Samples were thermally desorbed into a gas chromatograph with flame ionization detection for separation and determination of the components. Time-weighted average (TWA) concentrations were determined by plotting the amount of analyte collected versus the product of concentration and time (ppb•hr). A linear response was seen in the TWA curves for benzene, toluene, ethylbenzene and the three isomers of xylene (BTEX). These components had detection limits from 1.4 ppb for m- and p-xylene to 2.7 ppb for toluene. The effects of temperature and common environmental contaminants were examined. The advantages of this method include being environmentally friendly due to the lack of solvent and having less steps for analysis than many standard methods."],"dc:format":["application/pdf","434.9 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1279115371"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Analytical Chemistry","Chemistry","Environmental Science","Experiments","BTEX","water","benzene","toluene","ethylbenzene","xylene","permeation","membrane","GC","gas chromatography","thermal desorption"],"dc:title":["Permeation Sampling of BTEX and Gasoline"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:19Z"}