{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1284703306"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1284703306","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A Comparative Study for the Effect of Tissure Anisotropy on the Behavior of a Single Cardiac Pressure Cycle for a Symmetric Tri-Leaflet Valve","abstract":"Several attempts have been made in the past to understand the mechanics and function of the aortic valve and its surrounding geometric structures through finite element analysis, a powerful mathematical tool. As expressed by Thubrikar, there is a need to understand the geometry of the valve in a dynamic state. Sophisticated analysis of the complex interplay between the aortic root and the leaflets, as well as the development of stresses and strains in the leaflet during opening and closing is now possible using powerful computer techniques, which aid in a better understanding of the dynamics of the aortic valve. More importantly, these might prove invaluable in predicting patterns of failure of replacement devices or repair techniques in the work bench setting rather than experiencing it in the clinical situation, with unfortunate consequences. Earlier work on the aortic valve has been well documented along with substantial details of the geometry. Such dimensions have been used in recent studies also. The procedure illustrated by Thubrikar has been used to create the current model. The thickness of the leaflet is assumed to be constant in this model and the orientation was assigned based on the previous work done by Saleeb et al and his team. To check the capability of the material model developed by Saleeb et al and his team, Dokos et al work on the shear properties of passive ventricular myocardium results were compared. Comparative study was performed on the aortic valve model to observe the effect of tissue anisotropy for one complete cardiac cycle.","abstract_html":"Several attempts have been made in the past to understand the mechanics and function of the aortic valve and its surrounding geometric structures through finite element analysis, a powerful mathematical tool. As expressed by Thubrikar, there is a need to understand the geometry of the valve in a dynamic state. Sophisticated analysis of the complex interplay between the aortic root and the leaflets, as well as the development of stresses and strains in the leaflet during opening and closing is now possible using powerful computer techniques, which aid in a better understanding of the dynamics of the aortic valve. More importantly, these might prove invaluable in predicting patterns of failure of replacement devices or repair techniques in the work bench setting rather than experiencing it in the clinical situation, with unfortunate consequences. Earlier work on the aortic valve has been well documented along with substantial details of the geometry. Such dimensions have been used in recent studies also. The procedure illustrated by Thubrikar has been used to create the current model. The thickness of the leaflet is assumed to be constant in this model and the orientation was assigned based on the previous work done by Saleeb et al and his team. To check the capability of the material model developed by Saleeb et al and his team, Dokos et al work on the shear properties of passive ventricular myocardium results were compared. Comparative study was performed on the aortic valve model to observe the effect of tissue anisotropy for one complete cardiac cycle.","abstract_has_math":false,"creators":["Thomas, Vineet Sunny"],"institution":"University of Akron","degree_name":"Master of Science in Engineering","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Saleeb, Dr. Atef"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-12-13","date_published":"2010-12-13","updated_at":"2026-11-27T04:13:19Z","subjects":["Engineering","Aortic valve","Three dimensional tri-leaflet valve","Anisotropy"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1284703306","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1284703306","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1284703306","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1284703306","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Saleeb, Dr. Atef"]},{"key":"dc:creator","label":"Author","values":["Thomas, Vineet Sunny"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-12-13"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","Aortic valve","Three dimensional tri-leaflet valve","Anisotropy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1284703306"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Several attempts have been made in the past to understand the mechanics and function of the aortic valve and its surrounding geometric structures through finite element analysis, a powerful mathematical tool. As expressed by Thubrikar, there is a need to understand the geometry of the valve in a dynamic state. Sophisticated analysis of the complex interplay between the aortic root and the leaflets, as well as the development of stresses and strains in the leaflet during opening and closing is now possible using powerful computer techniques, which aid in a better understanding of the dynamics of the aortic valve. More importantly, these might prove invaluable in predicting patterns of failure of replacement devices or repair techniques in the work bench setting rather than experiencing it in the clinical situation, with unfortunate consequences. Earlier work on the aortic valve has been well documented along with substantial details of the geometry. Such dimensions have been used in recent studies also. The procedure illustrated by Thubrikar has been used to create the current model. The thickness of the leaflet is assumed to be constant in this model and the orientation was assigned based on the previous work done by Saleeb et al and his team. To check the capability of the material model developed by Saleeb et al and his team, Dokos et al work on the shear properties of passive ventricular myocardium results were compared. Comparative study was performed on the aortic valve model to observe the effect of tissue anisotropy for one complete cardiac cycle."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","2.26 MB"]},{"key":"dc:title","label":"Title","values":["A Comparative Study for the Effect of Tissure Anisotropy on the Behavior of a Single Cardiac Pressure Cycle for a Symmetric Tri-Leaflet Valve"]}]}],"canonical_facts":{"dc:contributor.advisor":["Saleeb, Dr. Atef"],"dc:creator":["Thomas, Vineet Sunny"],"dc:date":["2010-12-13"],"dc:description":["Several attempts have been made in the past to understand the mechanics and function of the aortic valve and its surrounding geometric structures through finite element analysis, a powerful mathematical tool. As expressed by Thubrikar, there is a need to understand the geometry of the valve in a dynamic state. Sophisticated analysis of the complex interplay between the aortic root and the leaflets, as well as the development of stresses and strains in the leaflet during opening and closing is now possible using powerful computer techniques, which aid in a better understanding of the dynamics of the aortic valve. More importantly, these might prove invaluable in predicting patterns of failure of replacement devices or repair techniques in the work bench setting rather than experiencing it in the clinical situation, with unfortunate consequences. Earlier work on the aortic valve has been well documented along with substantial details of the geometry. Such dimensions have been used in recent studies also. The procedure illustrated by Thubrikar has been used to create the current model. The thickness of the leaflet is assumed to be constant in this model and the orientation was assigned based on the previous work done by Saleeb et al and his team. To check the capability of the material model developed by Saleeb et al and his team, Dokos et al work on the shear properties of passive ventricular myocardium results were compared. Comparative study was performed on the aortic valve model to observe the effect of tissue anisotropy for one complete cardiac cycle."],"dc:format":["application/pdf","2.26 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1284703306"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering","Aortic valve","Three dimensional tri-leaflet valve","Anisotropy"],"dc:title":["A Comparative Study for the Effect of Tissure Anisotropy on the Behavior of a Single Cardiac Pressure Cycle for a Symmetric Tri-Leaflet Valve"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:19Z"}