{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1289328504"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1289328504","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Development of a Closed-loop Resonant Fatigue Testing Methodology and Experimental Life Test of Aluminum Alloy","abstract":"A vibration-based testing methodology is presented that assesses fatigue behavior of material for metallic structure. To minimize the testing duration, the test setup is designed for a base-excited multiple-specimen arrangement driven in a high-frequency resonant mode, which allows completion of fatigue testing in an accelerated period. A high performance electro-dynamic exciter (shaker) is used to generate harmonic oscillation of cantilever beam specimens, which are clasped on the shaker armature with specially-designed clamp fixtures. The shaker operates in closed-loop control with dynamic specimen response feedback provided by a scanning laser vibrometer. A test coordinator function is developed to synchronize the shaker controller and the laser vibrometer, and to complete the closed-loop scheme: the test coordinator monitors structural health of the test specimens throughout the test period, recognizes change in specimen dynamic behavior due to fatigue crack initiation, terminates test progression, and acquires test data in an orderly manner. Topological design is completed by constructing an analytical model and performing finite element analysis for the specimen and fixture geometry such that peak stress does not occur at the clamping fixture attachment points. Experimental stress evaluation is conducted to verify the specimen stress predictions. A successful application of the experimental methodology is demonstrated by validation tests with aluminum specimens subjected to fully-reversed bending stress.","abstract_html":"A vibration-based testing methodology is presented that assesses fatigue behavior of material for metallic structure. To minimize the testing duration, the test setup is designed for a base-excited multiple-specimen arrangement driven in a high-frequency resonant mode, which allows completion of fatigue testing in an accelerated period. A high performance electro-dynamic exciter (shaker) is used to generate harmonic oscillation of cantilever beam specimens, which are clasped on the shaker armature with specially-designed clamp fixtures. The shaker operates in closed-loop control with dynamic specimen response feedback provided by a scanning laser vibrometer. A test coordinator function is developed to synchronize the shaker controller and the laser vibrometer, and to complete the closed-loop scheme: the test coordinator monitors structural health of the test specimens throughout the test period, recognizes change in specimen dynamic behavior due to fatigue crack initiation, terminates test progression, and acquires test data in an orderly manner. Topological design is completed by constructing an analytical model and performing finite element analysis for the specimen and fixture geometry such that peak stress does not occur at the clamping fixture attachment points. Experimental stress evaluation is conducted to verify the specimen stress predictions. A successful application of the experimental methodology is demonstrated by validation tests with aluminum specimens subjected to fully-reversed bending stress.","abstract_has_math":false,"creators":["Abdullah, A.B.M."],"institution":"University of Akron","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Yun, Gun Jin"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-12-13","date_published":"2010-12-13","updated_at":"2026-11-27T04:13:19Z","subjects":["Engineering","High-cycle fatigue","Vibration-based testing","Scanning laser vibrometer","Shaker controller","Closed-loop testing","Bending fatigue","Experimental fatigue testing","Resonant fatigue"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1289328504","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1289328504","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1289328504","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1289328504","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yun, Gun Jin"]},{"key":"dc:creator","label":"Author","values":["Abdullah, A.B.M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-12-13"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","High-cycle fatigue","Vibration-based testing","Scanning laser vibrometer","Shaker controller","Closed-loop testing","Bending fatigue","Experimental fatigue testing","Resonant fatigue"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1289328504"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A vibration-based testing methodology is presented that assesses fatigue behavior of material for metallic structure. To minimize the testing duration, the test setup is designed for a base-excited multiple-specimen arrangement driven in a high-frequency resonant mode, which allows completion of fatigue testing in an accelerated period. A high performance electro-dynamic exciter (shaker) is used to generate harmonic oscillation of cantilever beam specimens, which are clasped on the shaker armature with specially-designed clamp fixtures. The shaker operates in closed-loop control with dynamic specimen response feedback provided by a scanning laser vibrometer. A test coordinator function is developed to synchronize the shaker controller and the laser vibrometer, and to complete the closed-loop scheme: the test coordinator monitors structural health of the test specimens throughout the test period, recognizes change in specimen dynamic behavior due to fatigue crack initiation, terminates test progression, and acquires test data in an orderly manner. Topological design is completed by constructing an analytical model and performing finite element analysis for the specimen and fixture geometry such that peak stress does not occur at the clamping fixture attachment points. Experimental stress evaluation is conducted to verify the specimen stress predictions. A successful application of the experimental methodology is demonstrated by validation tests with aluminum specimens subjected to fully-reversed bending stress."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.135","14.86 MB"]},{"key":"dc:title","label":"Title","values":["Development of a Closed-loop Resonant Fatigue Testing Methodology and Experimental Life Test of Aluminum Alloy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Yun, Gun Jin"],"dc:creator":["Abdullah, A.B.M."],"dc:date":["2010-12-13"],"dc:description":["A vibration-based testing methodology is presented that assesses fatigue behavior of material for metallic structure. To minimize the testing duration, the test setup is designed for a base-excited multiple-specimen arrangement driven in a high-frequency resonant mode, which allows completion of fatigue testing in an accelerated period. A high performance electro-dynamic exciter (shaker) is used to generate harmonic oscillation of cantilever beam specimens, which are clasped on the shaker armature with specially-designed clamp fixtures. The shaker operates in closed-loop control with dynamic specimen response feedback provided by a scanning laser vibrometer. A test coordinator function is developed to synchronize the shaker controller and the laser vibrometer, and to complete the closed-loop scheme: the test coordinator monitors structural health of the test specimens throughout the test period, recognizes change in specimen dynamic behavior due to fatigue crack initiation, terminates test progression, and acquires test data in an orderly manner. Topological design is completed by constructing an analytical model and performing finite element analysis for the specimen and fixture geometry such that peak stress does not occur at the clamping fixture attachment points. Experimental stress evaluation is conducted to verify the specimen stress predictions. A successful application of the experimental methodology is demonstrated by validation tests with aluminum specimens subjected to fully-reversed bending stress."],"dc:format":["application/pdf","p.135","14.86 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1289328504"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering","High-cycle fatigue","Vibration-based testing","Scanning laser vibrometer","Shaker controller","Closed-loop testing","Bending fatigue","Experimental fatigue testing","Resonant fatigue"],"dc:title":["Development of a Closed-loop Resonant Fatigue Testing Methodology and Experimental Life Test of Aluminum Alloy"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:19Z"}