{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1344453788"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1344453788","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Optimization of Intermittent Pneumatic Compression for Lower Extremities, Computational Results","abstract":"<p>Intermittent pneumatic compression (IPC) devices have proven in the clinic to be a viable alternative to traditional prophylaxis for treatment of deep venous thrombosis (DVT). Yet, the physiological effect of IPC application is not entirely classified. A computational model of the lower leg circulatory system was developed to resolve a more complete understanding, and therefore improved treatment methods. IPC parameters were changed for each simulation, and resulting hemodynamic responses were recorded.</p><p>The study concludes that wavelike compression, quick rise time, and high pressure application are parameters that are most effective to be used in IPC, because it allows the most efficient blood clearance from blood vessels. The salience of this model is that it can be adapted to individual patients. Modifying model parameters will offer a higher degree of IPC optimization, and ultimately customized treatment. This and other theoretical models give greater insight to the nature of blood flow, providing patients greater protection from DVT.</p>","abstract_html":"&lt;p&gt;Intermittent pneumatic compression (IPC) devices have proven in the clinic to be a viable alternative to traditional prophylaxis for treatment of deep venous thrombosis (DVT). Yet, the physiological effect of IPC application is not entirely classified. A computational model of the lower leg circulatory system was developed to resolve a more complete understanding, and therefore improved treatment methods. IPC parameters were changed for each simulation, and resulting hemodynamic responses were recorded.&lt;/p&gt;&lt;p&gt;The study concludes that wavelike compression, quick rise time, and high pressure application are parameters that are most effective to be used in IPC, because it allows the most efficient blood clearance from blood vessels. The salience of this model is that it can be adapted to individual patients. Modifying model parameters will offer a higher degree of IPC optimization, and ultimately customized treatment. This and other theoretical models give greater insight to the nature of blood flow, providing patients greater protection from DVT.&lt;/p&gt;","abstract_has_math":false,"creators":["Becker, Michaeline"],"institution":"University of Akron","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Reddy, Narender"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-09-05","date_published":"2012-09-05","updated_at":"2026-11-27T04:13:24Z","subjects":["Biomedical Engineering","Biomedical Research","intermittent pneumatic compression","deep venous thrombosis","computational model","lower leg hemodynamics","venous hemodynamics","lower extremity","external compression"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1344453788","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1344453788","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1344453788","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1344453788","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Reddy, Narender"]},{"key":"dc:creator","label":"Author","values":["Becker, Michaeline"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-09-05"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Biomedical Research","intermittent pneumatic compression","deep venous thrombosis","computational model","lower leg hemodynamics","venous hemodynamics","lower extremity","external compression"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1344453788"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Intermittent pneumatic compression (IPC) devices have proven in the clinic to be a viable alternative to traditional prophylaxis for treatment of deep venous thrombosis (DVT). Yet, the physiological effect of IPC application is not entirely classified. A computational model of the lower leg circulatory system was developed to resolve a more complete understanding, and therefore improved treatment methods. IPC parameters were changed for each simulation, and resulting hemodynamic responses were recorded.</p><p>The study concludes that wavelike compression, quick rise time, and high pressure application are parameters that are most effective to be used in IPC, because it allows the most efficient blood clearance from blood vessels. The salience of this model is that it can be adapted to individual patients. Modifying model parameters will offer a higher degree of IPC optimization, and ultimately customized treatment. This and other theoretical models give greater insight to the nature of blood flow, providing patients greater protection from DVT.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.71","5.16 MB"]},{"key":"dc:title","label":"Title","values":["Optimization of Intermittent Pneumatic Compression for Lower Extremities, Computational Results"]}]}],"canonical_facts":{"dc:contributor.advisor":["Reddy, Narender"],"dc:creator":["Becker, Michaeline"],"dc:date":["2012-09-05"],"dc:description":["<p>Intermittent pneumatic compression (IPC) devices have proven in the clinic to be a viable alternative to traditional prophylaxis for treatment of deep venous thrombosis (DVT). Yet, the physiological effect of IPC application is not entirely classified. A computational model of the lower leg circulatory system was developed to resolve a more complete understanding, and therefore improved treatment methods. IPC parameters were changed for each simulation, and resulting hemodynamic responses were recorded.</p><p>The study concludes that wavelike compression, quick rise time, and high pressure application are parameters that are most effective to be used in IPC, because it allows the most efficient blood clearance from blood vessels. The salience of this model is that it can be adapted to individual patients. Modifying model parameters will offer a higher degree of IPC optimization, and ultimately customized treatment. This and other theoretical models give greater insight to the nature of blood flow, providing patients greater protection from DVT.</p>"],"dc:format":["application/pdf","p.71","5.16 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1344453788"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Biomedical Research","intermittent pneumatic compression","deep venous thrombosis","computational model","lower leg hemodynamics","venous hemodynamics","lower extremity","external compression"],"dc:title":["Optimization of Intermittent Pneumatic Compression for Lower Extremities, Computational Results"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:13:24Z"}