{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1374434592"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1374434592","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Fabrication of PPF Based Drug Containing Microneedle Arrays by Microstereolithography","abstract":"Transdermal drug delivery systems are one of the impetus areas in drug delivery research due to their distinguished advantages over oral and hypodermicneedles. Microneedle based transdermal drug delivery system is one of the emerging devices for drug delivery in recent years. Microneedles deliver drug into the epidermis without disrupting the nerves endings. Many researchers have designed different microneedles and have fabricated those using different materials and fabrication processes. In this current work, microneedles were fabricated using a biodegradable and biocompatible polymer poly(propylene fumarate) (PPF), which is being recently used for different biomedical applications. The fabrication process adopted in this work was microstereolithography which is an emerging 3D microfabrication process that is being explored in biomedical applications since few years. An attempt was made to fabricate PPF based microneedle arrays containing drug (BSA) using microstereolithography process. To obtain these microneedle arrays, firstly PPF was synthesized and characterized, and then different prepolymers were prepared using PPF and different ratios of drug for the fabrication. The microstereolithography system that was used for fabrication was developed, calibrated and verified. Since these materials are new, their material properties such as viscosity, cure depth and exposure time, and mechanical properties such as elastic modulus and ultimate compressive strength were obtained by conducting different experiments. Finally, the microneedles arrays were fabricated and were characterized using a microscope and scanning electron microscope.","abstract_html":"Transdermal drug delivery systems are one of the impetus areas in drug delivery research due to their distinguished advantages over oral and hypodermicneedles. Microneedle based transdermal drug delivery system is one of the emerging devices for drug delivery in recent years. Microneedles deliver drug into the epidermis without disrupting the nerves endings. Many researchers have designed different microneedles and have fabricated those using different materials and fabrication processes. In this current work, microneedles were fabricated using a biodegradable and biocompatible polymer poly(propylene fumarate) (PPF), which is being recently used for different biomedical applications. The fabrication process adopted in this work was microstereolithography which is an emerging 3D microfabrication process that is being explored in biomedical applications since few years. An attempt was made to fabricate PPF based microneedle arrays containing drug (BSA) using microstereolithography process. To obtain these microneedle arrays, firstly PPF was synthesized and characterized, and then different prepolymers were prepared using PPF and different ratios of drug for the fabrication. The microstereolithography system that was used for fabrication was developed, calibrated and verified. Since these materials are new, their material properties such as viscosity, cure depth and exposure time, and mechanical properties such as elastic modulus and ultimate compressive strength were obtained by conducting different experiments. Finally, the microneedles arrays were fabricated and were characterized using a microscope and scanning electron microscope.","abstract_has_math":false,"creators":["Mantha, Satya Nymisha"],"institution":"University of Akron","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Choi, Jae-Won"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-09-20","date_published":"2013-09-20","updated_at":"2026-11-27T04:38:40Z","subjects":["Mechanical Engineering","Medicine"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1374434592","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1374434592","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1374434592","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1374434592","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Choi, Jae-Won"]},{"key":"dc:creator","label":"Author","values":["Mantha, Satya Nymisha"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-09-20"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","Medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1374434592"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Transdermal drug delivery systems are one of the impetus areas in drug delivery research due to their distinguished advantages over oral and hypodermicneedles. Microneedle based transdermal drug delivery system is one of the emerging devices for drug delivery in recent years. Microneedles deliver drug into the epidermis without disrupting the nerves endings. Many researchers have designed different microneedles and have fabricated those using different materials and fabrication processes. In this current work, microneedles were fabricated using a biodegradable and biocompatible polymer poly(propylene fumarate) (PPF), which is being recently used for different biomedical applications. The fabrication process adopted in this work was microstereolithography which is an emerging 3D microfabrication process that is being explored in biomedical applications since few years. An attempt was made to fabricate PPF based microneedle arrays containing drug (BSA) using microstereolithography process. To obtain these microneedle arrays, firstly PPF was synthesized and characterized, and then different prepolymers were prepared using PPF and different ratios of drug for the fabrication. The microstereolithography system that was used for fabrication was developed, calibrated and verified. Since these materials are new, their material properties such as viscosity, cure depth and exposure time, and mechanical properties such as elastic modulus and ultimate compressive strength were obtained by conducting different experiments. Finally, the microneedles arrays were fabricated and were characterized using a microscope and scanning electron microscope."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.134","2.69 MB"]},{"key":"dc:title","label":"Title","values":["Fabrication of PPF Based Drug Containing Microneedle Arrays by Microstereolithography"]}]}],"canonical_facts":{"dc:contributor.advisor":["Choi, Jae-Won"],"dc:creator":["Mantha, Satya Nymisha"],"dc:date":["2013-09-20"],"dc:description":["Transdermal drug delivery systems are one of the impetus areas in drug delivery research due to their distinguished advantages over oral and hypodermicneedles. Microneedle based transdermal drug delivery system is one of the emerging devices for drug delivery in recent years. Microneedles deliver drug into the epidermis without disrupting the nerves endings. Many researchers have designed different microneedles and have fabricated those using different materials and fabrication processes. In this current work, microneedles were fabricated using a biodegradable and biocompatible polymer poly(propylene fumarate) (PPF), which is being recently used for different biomedical applications. The fabrication process adopted in this work was microstereolithography which is an emerging 3D microfabrication process that is being explored in biomedical applications since few years. An attempt was made to fabricate PPF based microneedle arrays containing drug (BSA) using microstereolithography process. To obtain these microneedle arrays, firstly PPF was synthesized and characterized, and then different prepolymers were prepared using PPF and different ratios of drug for the fabrication. The microstereolithography system that was used for fabrication was developed, calibrated and verified. Since these materials are new, their material properties such as viscosity, cure depth and exposure time, and mechanical properties such as elastic modulus and ultimate compressive strength were obtained by conducting different experiments. Finally, the microneedles arrays were fabricated and were characterized using a microscope and scanning electron microscope."],"dc:format":["application/pdf","p.134","2.69 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1374434592"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","Medicine"],"dc:title":["Fabrication of PPF Based Drug Containing Microneedle Arrays by Microstereolithography"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:38:40Z"}