{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1429538820"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1429538820","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Damage-Free Seismic-Resistant Self-Centering Friction-Damped Braced Frames with Buckling-Restrained Columns","abstract":"Conventional concentrically braced frame (CBF) systems have limited drift capacity prior to brace buckling, and related damage leads to deterioration in strength and stiffness. CBFs are also susceptible to weak story failure. A pin- supported self-centering friction-damped braced frame system with buckling-restrained columns (FDBF-BRC) is being developed to provide significant drift capacity while limiting damage due to residual drift and soft-story mechanisms. The FDBF-BRC system consists of beams, columns, and braces branching off a central column, with buckling restrained columns (BRCs) incorporated into the system at the first story external column positions. The BRCs and friction generated at lateral-load bearings at each floor level are used to dissipate energy to minimize the overall seismic response of the FDBF-BRC system. Vertically aligned post-tensioning bars provide additional overturning moment resistance and aid in self-centering the system to eliminate residual drift. The pin support condition and the lateral stiffness of the system enable it to exhibit a nearly uniform inter-story drift distribution. In this study, a suite of 44 DBE-level ground motions used in FEMA P695 is numerically applied to several FDBF- BRCs to demonstrate the seismic performance of the system. The results show that the FDBF-BRC system has a nearly uniform inter-story drift response, high ductility, and a high energy dissipation capacity, and is an effective seismic-resistant system.","abstract_html":"Conventional concentrically braced frame (CBF) systems have limited drift capacity prior to brace buckling, and related damage leads to deterioration in strength and stiffness. CBFs are also susceptible to weak story failure. A pin- supported self-centering friction-damped braced frame system with buckling-restrained columns (FDBF-BRC) is being developed to provide significant drift capacity while limiting damage due to residual drift and soft-story mechanisms. The FDBF-BRC system consists of beams, columns, and braces branching off a central column, with buckling restrained columns (BRCs) incorporated into the system at the first story external column positions. The BRCs and friction generated at lateral-load bearings at each floor level are used to dissipate energy to minimize the overall seismic response of the FDBF-BRC system. Vertically aligned post-tensioning bars provide additional overturning moment resistance and aid in self-centering the system to eliminate residual drift. The pin support condition and the lateral stiffness of the system enable it to exhibit a nearly uniform inter-story drift distribution. In this study, a suite of 44 DBE-level ground motions used in FEMA P695 is numerically applied to several FDBF- BRCs to demonstrate the seismic performance of the system. The results show that the FDBF-BRC system has a nearly uniform inter-story drift response, high ductility, and a high energy dissipation capacity, and is an effective seismic-resistant system.","abstract_has_math":false,"creators":["Blebo, Felix C."],"institution":"University of Akron","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Roke, David"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-06-26","date_published":"2015-06-26","updated_at":"2026-11-27T04:40:18Z","subjects":["Civil Engineering","Engineering","Post-tensioned steel braced frame, self-centering","friction damping","seismic-resistant","buckling-restrained column","buckling-restrained braces","soft story failure","residual drift","damage free seismic reistant systems"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1429538820","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1429538820","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1429538820","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1429538820","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Roke, David"]},{"key":"dc:creator","label":"Author","values":["Blebo, Felix C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-06-26"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil Engineering","Engineering","Post-tensioned steel braced frame, self-centering","friction damping","seismic-resistant","buckling-restrained column","buckling-restrained braces","soft story failure","residual drift","damage free seismic reistant systems"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1429538820"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Conventional concentrically braced frame (CBF) systems have limited drift capacity prior to brace buckling, and related damage leads to deterioration in strength and stiffness. CBFs are also susceptible to weak story failure. A pin- supported self-centering friction-damped braced frame system with buckling-restrained columns (FDBF-BRC) is being developed to provide significant drift capacity while limiting damage due to residual drift and soft-story mechanisms. The FDBF-BRC system consists of beams, columns, and braces branching off a central column, with buckling restrained columns (BRCs) incorporated into the system at the first story external column positions. The BRCs and friction generated at lateral-load bearings at each floor level are used to dissipate energy to minimize the overall seismic response of the FDBF-BRC system. Vertically aligned post-tensioning bars provide additional overturning moment resistance and aid in self-centering the system to eliminate residual drift. The pin support condition and the lateral stiffness of the system enable it to exhibit a nearly uniform inter-story drift distribution. In this study, a suite of 44 DBE-level ground motions used in FEMA P695 is numerically applied to several FDBF- BRCs to demonstrate the seismic performance of the system. The results show that the FDBF-BRC system has a nearly uniform inter-story drift response, high ductility, and a high energy dissipation capacity, and is an effective seismic-resistant system."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.172","6.35 MB"]},{"key":"dc:title","label":"Title","values":["Damage-Free Seismic-Resistant Self-Centering Friction-Damped Braced Frames with Buckling-Restrained Columns"]}]}],"canonical_facts":{"dc:contributor.advisor":["Roke, David"],"dc:creator":["Blebo, Felix C."],"dc:date":["2015-06-26"],"dc:description":["Conventional concentrically braced frame (CBF) systems have limited drift capacity prior to brace buckling, and related damage leads to deterioration in strength and stiffness. CBFs are also susceptible to weak story failure. A pin- supported self-centering friction-damped braced frame system with buckling-restrained columns (FDBF-BRC) is being developed to provide significant drift capacity while limiting damage due to residual drift and soft-story mechanisms. The FDBF-BRC system consists of beams, columns, and braces branching off a central column, with buckling restrained columns (BRCs) incorporated into the system at the first story external column positions. The BRCs and friction generated at lateral-load bearings at each floor level are used to dissipate energy to minimize the overall seismic response of the FDBF-BRC system. Vertically aligned post-tensioning bars provide additional overturning moment resistance and aid in self-centering the system to eliminate residual drift. The pin support condition and the lateral stiffness of the system enable it to exhibit a nearly uniform inter-story drift distribution. In this study, a suite of 44 DBE-level ground motions used in FEMA P695 is numerically applied to several FDBF- BRCs to demonstrate the seismic performance of the system. The results show that the FDBF-BRC system has a nearly uniform inter-story drift response, high ductility, and a high energy dissipation capacity, and is an effective seismic-resistant system."],"dc:format":["application/pdf","p.172","6.35 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1429538820"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Civil Engineering","Engineering","Post-tensioned steel braced frame, self-centering","friction damping","seismic-resistant","buckling-restrained column","buckling-restrained braces","soft story failure","residual drift","damage free seismic reistant systems"],"dc:title":["Damage-Free Seismic-Resistant Self-Centering Friction-Damped Braced Frames with Buckling-Restrained Columns"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:40:18Z"}