{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1435153573"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1435153573","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Development of New Treatment Modalities for Kidney/Ureter Stones","abstract":"The number of people suffering from urolithiasis (formation of kidney stones) has increased over the past few decades. Ureteroscopic stone extraction devices are effective and ubiquitous tools in the management of urolithiasis. These devices, however, have the potential to cause injury to the ureter. Avulsion and perforation of the ureter as a result of excessive forces on the extraction device are the most serious complications of this treatment. Moreover, effective management of kidney stones depends on their size, location, and composition. In this dissertation, different treatment modalities for kidney stone disease are discussed. In the first part of this dissertation, analysis of the peristaltic movement, which drives the urine from the kidneys to the bladder through the ureter, is presented. More specifically, different sizes and types of kidney stones are modeled inside the ureter and their effects on the urine flow and pressure on the ureter wall are studied. It is concluded that in addition to the stone size, different stone shapes result in different pressures on the ureter wall. In the second part of this dissertation, a kidney basket prototype with a force sensor has been developed. This device was built based on the measured injury forces during basketing, using two different setups, a benchtop model and an ex-vivo porcine ureter. The force sensor provides instantaneous visual force measurements imposed on the ureter wall during stone extraction, and thereby, aids in reducing the risk of complications by highlighting the safety and hazardous extraction forces. The tests were performed in conjunction with the Division of Urology, Southern Illinois University, School of Medicine, Springfield, IL. The results obtained from these tests were consistent with injury forces reported in the literature. The designed prototype, together with the stone analysis performed in this study could potentially lead to an improvement in the treatment of urolithiasis and enhance patient outcomes.","abstract_html":"The number of people suffering from urolithiasis (formation of kidney stones) has increased over the past few decades. Ureteroscopic stone extraction devices are effective and ubiquitous tools in the management of urolithiasis. These devices, however, have the potential to cause injury to the ureter. Avulsion and perforation of the ureter as a result of excessive forces on the extraction device are the most serious complications of this treatment. Moreover, effective management of kidney stones depends on their size, location, and composition. In this dissertation, different treatment modalities for kidney stone disease are discussed. In the first part of this dissertation, analysis of the peristaltic movement, which drives the urine from the kidneys to the bladder through the ureter, is presented. More specifically, different sizes and types of kidney stones are modeled inside the ureter and their effects on the urine flow and pressure on the ureter wall are studied. It is concluded that in addition to the stone size, different stone shapes result in different pressures on the ureter wall. In the second part of this dissertation, a kidney basket prototype with a force sensor has been developed. This device was built based on the measured injury forces during basketing, using two different setups, a benchtop model and an ex-vivo porcine ureter. The force sensor provides instantaneous visual force measurements imposed on the ureter wall during stone extraction, and thereby, aids in reducing the risk of complications by highlighting the safety and hazardous extraction forces. The tests were performed in conjunction with the Division of Urology, Southern Illinois University, School of Medicine, Springfield, IL. The results obtained from these tests were consistent with injury forces reported in the literature. The designed prototype, together with the stone analysis performed in this study could potentially lead to an improvement in the treatment of urolithiasis and enhance patient outcomes.","abstract_has_math":false,"creators":["Najafi, Zahra"],"institution":"University of Akron","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Mahajan, Ajay"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-10","date_published":"2015-09-10","updated_at":"2026-11-27T04:40:27Z","subjects":["Biomedical Engineering","Biomechanics","Design","Computational Fluid Dynamic","ureter peristaltic mathematical model","ureteroscopy extraction force measurements","design of a new smart kidney basket"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1435153573","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1435153573","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1435153573","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1435153573","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mahajan, Ajay"]},{"key":"dc:creator","label":"Author","values":["Najafi, Zahra"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-10"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Biomechanics","Design","Computational Fluid Dynamic","ureter peristaltic mathematical model","ureteroscopy extraction force measurements","design of a new smart kidney basket"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1435153573"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The number of people suffering from urolithiasis (formation of kidney stones) has increased over the past few decades. Ureteroscopic stone extraction devices are effective and ubiquitous tools in the management of urolithiasis. These devices, however, have the potential to cause injury to the ureter. Avulsion and perforation of the ureter as a result of excessive forces on the extraction device are the most serious complications of this treatment. Moreover, effective management of kidney stones depends on their size, location, and composition. In this dissertation, different treatment modalities for kidney stone disease are discussed. In the first part of this dissertation, analysis of the peristaltic movement, which drives the urine from the kidneys to the bladder through the ureter, is presented. More specifically, different sizes and types of kidney stones are modeled inside the ureter and their effects on the urine flow and pressure on the ureter wall are studied. It is concluded that in addition to the stone size, different stone shapes result in different pressures on the ureter wall. In the second part of this dissertation, a kidney basket prototype with a force sensor has been developed. This device was built based on the measured injury forces during basketing, using two different setups, a benchtop model and an ex-vivo porcine ureter. The force sensor provides instantaneous visual force measurements imposed on the ureter wall during stone extraction, and thereby, aids in reducing the risk of complications by highlighting the safety and hazardous extraction forces. The tests were performed in conjunction with the Division of Urology, Southern Illinois University, School of Medicine, Springfield, IL. The results obtained from these tests were consistent with injury forces reported in the literature. The designed prototype, together with the stone analysis performed in this study could potentially lead to an improvement in the treatment of urolithiasis and enhance patient outcomes."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.226","10.01 MB"]},{"key":"dc:title","label":"Title","values":["Development of New Treatment Modalities for Kidney/Ureter Stones"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mahajan, Ajay"],"dc:creator":["Najafi, Zahra"],"dc:date":["2015-09-10"],"dc:description":["The number of people suffering from urolithiasis (formation of kidney stones) has increased over the past few decades. Ureteroscopic stone extraction devices are effective and ubiquitous tools in the management of urolithiasis. These devices, however, have the potential to cause injury to the ureter. Avulsion and perforation of the ureter as a result of excessive forces on the extraction device are the most serious complications of this treatment. Moreover, effective management of kidney stones depends on their size, location, and composition. In this dissertation, different treatment modalities for kidney stone disease are discussed. In the first part of this dissertation, analysis of the peristaltic movement, which drives the urine from the kidneys to the bladder through the ureter, is presented. More specifically, different sizes and types of kidney stones are modeled inside the ureter and their effects on the urine flow and pressure on the ureter wall are studied. It is concluded that in addition to the stone size, different stone shapes result in different pressures on the ureter wall. In the second part of this dissertation, a kidney basket prototype with a force sensor has been developed. This device was built based on the measured injury forces during basketing, using two different setups, a benchtop model and an ex-vivo porcine ureter. The force sensor provides instantaneous visual force measurements imposed on the ureter wall during stone extraction, and thereby, aids in reducing the risk of complications by highlighting the safety and hazardous extraction forces. The tests were performed in conjunction with the Division of Urology, Southern Illinois University, School of Medicine, Springfield, IL. The results obtained from these tests were consistent with injury forces reported in the literature. The designed prototype, together with the stone analysis performed in this study could potentially lead to an improvement in the treatment of urolithiasis and enhance patient outcomes."],"dc:format":["application/pdf","p.226","10.01 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1435153573"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Biomechanics","Design","Computational Fluid Dynamic","ureter peristaltic mathematical model","ureteroscopy extraction force measurements","design of a new smart kidney basket"],"dc:title":["Development of New Treatment Modalities for Kidney/Ureter Stones"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:40:27Z"}