{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1447634222"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1447634222","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Label Free and Multiplexed Immunosensor Chips for Detection of Macromolecular and Cellular Biomarkers","abstract":"Biomarker detection represents an important task for many scientific fields such as disease diagnosis, biodefense, environmental monitoring and biological research. In this research, micro resistive pulse immunoaggregation sensors were studied to quantitatively detect macromolecular and cellular biomarker concentrations. First, to prove the concept of the immunoaggregation assay and resistive pulse sensing, goat anti-rabbit IgG, used as a model biomarker, was detected by the micro resistive pulse immunoaggregation sensor. A detection range from 16.0 to 160 ng/mL was achieved. The human ferritin in 10% fetal bovine serum was then detected to prove the device’s performance in a complex media. A detection range from 0.104 to 208 ng/mL was achieved. In addition, the studies showed that the detection range can be shifted to lower and higher concentrations by decreasing and increasing MP concentrations, respectively.Second, the multiplexed immunoaggregation assay was also studied in this research to achieve multiple biomarker detection in a single test. A mixture consisting of multiple types of MPs functionalized by different antibody with different sizes and magnetic properties was used for testing the multiplexed assay. 2.00 µm non-magnetic MPs coated with rabbit anti-mouse IgG antibody and 2.80 µm magnetic MPs coated with goat anti-human ferritin antibody were used to detect the concentration of mouse anti-rabbit IgG and human ferritin, respectively. Detection ranges from 5.20 to 208 ng/mL and 3.10 to 51.2 × 10<sup>3</sup> ng/mL were achieved for human ferritin and mouse anti-rabbit IgG detection.Next, a two-stage resistive pulse sensor was invented to detect target cells in a mixed cell population. <i>S. cerevisiae</i> and <i>Chlorella</i> were used as target cells and control cells, respectively. The specific capture efficiency of <i>S. cerevisiae</i> was greater than 94.8%, while the nonspecific capture efficiency was less than 3.4%. <i>S. cerevisiae</i> ratio measurements in a mixture with <i>Chlorella</i> showed that for <i>S. cerevisiae</i> to <i>Chlorella</i> ratios ranging from 1.0 to 2.0, the measurement errors were less than 7%, while the errors were 20% to 32% for lower ratios, ranging from 0.1 to 0.5, caused by nonspecific attachment.The testing results demonstrated that the immunoaggregation biomarker sensor and MP cellular sensor enable reliable detection of target macromolecular and cellular biomarkers in samples at very low concentrations, without the fluorescence and enzyme labeling of biomarker. These innovative biosensors will lead to a fast and cost-effective bioassay instrument for disease diagnosis, environmental monitoring and homeland security.","abstract_html":"Biomarker detection represents an important task for many scientific fields such as disease diagnosis, biodefense, environmental monitoring and biological research. In this research, micro resistive pulse immunoaggregation sensors were studied to quantitatively detect macromolecular and cellular biomarker concentrations. First, to prove the concept of the immunoaggregation assay and resistive pulse sensing, goat anti-rabbit IgG, used as a model biomarker, was detected by the micro resistive pulse immunoaggregation sensor. A detection range from 16.0 to 160 ng/mL was achieved. The human ferritin in 10% fetal bovine serum was then detected to prove the device’s performance in a complex media. A detection range from 0.104 to 208 ng/mL was achieved. In addition, the studies showed that the detection range can be shifted to lower and higher concentrations by decreasing and increasing MP concentrations, respectively.Second, the multiplexed immunoaggregation assay was also studied in this research to achieve multiple biomarker detection in a single test. A mixture consisting of multiple types of MPs functionalized by different antibody with different sizes and magnetic properties was used for testing the multiplexed assay. 2.00 µm non-magnetic MPs coated with rabbit anti-mouse IgG antibody and 2.80 µm magnetic MPs coated with goat anti-human ferritin antibody were used to detect the concentration of mouse anti-rabbit IgG and human ferritin, respectively. Detection ranges from 5.20 to 208 ng/mL and 3.10 to 51.2 × 10&lt;sup&gt;3&lt;/sup&gt; ng/mL were achieved for human ferritin and mouse anti-rabbit IgG detection.Next, a two-stage resistive pulse sensor was invented to detect target cells in a mixed cell population. &lt;i&gt;S. cerevisiae&lt;/i&gt; and &lt;i&gt;Chlorella&lt;/i&gt; were used as target cells and control cells, respectively. The specific capture efficiency of &lt;i&gt;S. cerevisiae&lt;/i&gt; was greater than 94.8%, while the nonspecific capture efficiency was less than 3.4%. &lt;i&gt;S. cerevisiae&lt;/i&gt; ratio measurements in a mixture with &lt;i&gt;Chlorella&lt;/i&gt; showed that for &lt;i&gt;S. cerevisiae&lt;/i&gt; to &lt;i&gt;Chlorella&lt;/i&gt; ratios ranging from 1.0 to 2.0, the measurement errors were less than 7%, while the errors were 20% to 32% for lower ratios, ranging from 0.1 to 0.5, caused by nonspecific attachment.The testing results demonstrated that the immunoaggregation biomarker sensor and MP cellular sensor enable reliable detection of target macromolecular and cellular biomarkers in samples at very low concentrations, without the fluorescence and enzyme labeling of biomarker. These innovative biosensors will lead to a fast and cost-effective bioassay instrument for disease diagnosis, environmental monitoring and homeland security.","abstract_has_math":false,"creators":["Han, Yu"],"institution":"University of Akron","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Zhe , Jiang"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-11-27T04:40:46Z","subjects":["Mechanical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1447634222","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1447634222","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1447634222","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1447634222","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zhe , Jiang"]},{"key":"dc:creator","label":"Author","values":["Han, Yu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1447634222"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Biomarker detection represents an important task for many scientific fields such as disease diagnosis, biodefense, environmental monitoring and biological research. In this research, micro resistive pulse immunoaggregation sensors were studied to quantitatively detect macromolecular and cellular biomarker concentrations. First, to prove the concept of the immunoaggregation assay and resistive pulse sensing, goat anti-rabbit IgG, used as a model biomarker, was detected by the micro resistive pulse immunoaggregation sensor. A detection range from 16.0 to 160 ng/mL was achieved. The human ferritin in 10% fetal bovine serum was then detected to prove the device’s performance in a complex media. A detection range from 0.104 to 208 ng/mL was achieved. In addition, the studies showed that the detection range can be shifted to lower and higher concentrations by decreasing and increasing MP concentrations, respectively.Second, the multiplexed immunoaggregation assay was also studied in this research to achieve multiple biomarker detection in a single test. A mixture consisting of multiple types of MPs functionalized by different antibody with different sizes and magnetic properties was used for testing the multiplexed assay. 2.00 µm non-magnetic MPs coated with rabbit anti-mouse IgG antibody and 2.80 µm magnetic MPs coated with goat anti-human ferritin antibody were used to detect the concentration of mouse anti-rabbit IgG and human ferritin, respectively. Detection ranges from 5.20 to 208 ng/mL and 3.10 to 51.2 × 10<sup>3</sup> ng/mL were achieved for human ferritin and mouse anti-rabbit IgG detection.Next, a two-stage resistive pulse sensor was invented to detect target cells in a mixed cell population. <i>S. cerevisiae</i> and <i>Chlorella</i> were used as target cells and control cells, respectively. The specific capture efficiency of <i>S. cerevisiae</i> was greater than 94.8%, while the nonspecific capture efficiency was less than 3.4%. <i>S. cerevisiae</i> ratio measurements in a mixture with <i>Chlorella</i> showed that for <i>S. cerevisiae</i> to <i>Chlorella</i> ratios ranging from 1.0 to 2.0, the measurement errors were less than 7%, while the errors were 20% to 32% for lower ratios, ranging from 0.1 to 0.5, caused by nonspecific attachment.The testing results demonstrated that the immunoaggregation biomarker sensor and MP cellular sensor enable reliable detection of target macromolecular and cellular biomarkers in samples at very low concentrations, without the fluorescence and enzyme labeling of biomarker. These innovative biosensors will lead to a fast and cost-effective bioassay instrument for disease diagnosis, environmental monitoring and homeland security."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.138","4.34 MB"]},{"key":"dc:title","label":"Title","values":["Label Free and Multiplexed Immunosensor Chips for Detection of Macromolecular and Cellular Biomarkers"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zhe , Jiang"],"dc:creator":["Han, Yu"],"dc:date":["2015"],"dc:description":["Biomarker detection represents an important task for many scientific fields such as disease diagnosis, biodefense, environmental monitoring and biological research. In this research, micro resistive pulse immunoaggregation sensors were studied to quantitatively detect macromolecular and cellular biomarker concentrations. First, to prove the concept of the immunoaggregation assay and resistive pulse sensing, goat anti-rabbit IgG, used as a model biomarker, was detected by the micro resistive pulse immunoaggregation sensor. A detection range from 16.0 to 160 ng/mL was achieved. The human ferritin in 10% fetal bovine serum was then detected to prove the device’s performance in a complex media. A detection range from 0.104 to 208 ng/mL was achieved. In addition, the studies showed that the detection range can be shifted to lower and higher concentrations by decreasing and increasing MP concentrations, respectively.Second, the multiplexed immunoaggregation assay was also studied in this research to achieve multiple biomarker detection in a single test. A mixture consisting of multiple types of MPs functionalized by different antibody with different sizes and magnetic properties was used for testing the multiplexed assay. 2.00 µm non-magnetic MPs coated with rabbit anti-mouse IgG antibody and 2.80 µm magnetic MPs coated with goat anti-human ferritin antibody were used to detect the concentration of mouse anti-rabbit IgG and human ferritin, respectively. Detection ranges from 5.20 to 208 ng/mL and 3.10 to 51.2 × 10<sup>3</sup> ng/mL were achieved for human ferritin and mouse anti-rabbit IgG detection.Next, a two-stage resistive pulse sensor was invented to detect target cells in a mixed cell population. <i>S. cerevisiae</i> and <i>Chlorella</i> were used as target cells and control cells, respectively. The specific capture efficiency of <i>S. cerevisiae</i> was greater than 94.8%, while the nonspecific capture efficiency was less than 3.4%. <i>S. cerevisiae</i> ratio measurements in a mixture with <i>Chlorella</i> showed that for <i>S. cerevisiae</i> to <i>Chlorella</i> ratios ranging from 1.0 to 2.0, the measurement errors were less than 7%, while the errors were 20% to 32% for lower ratios, ranging from 0.1 to 0.5, caused by nonspecific attachment.The testing results demonstrated that the immunoaggregation biomarker sensor and MP cellular sensor enable reliable detection of target macromolecular and cellular biomarkers in samples at very low concentrations, without the fluorescence and enzyme labeling of biomarker. These innovative biosensors will lead to a fast and cost-effective bioassay instrument for disease diagnosis, environmental monitoring and homeland security."],"dc:format":["application/pdf","p.138","4.34 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1447634222"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering"],"dc:title":["Label Free and Multiplexed Immunosensor Chips for Detection of Macromolecular and Cellular Biomarkers"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:40:46Z"}