{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1464713357"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1464713357","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Development Of An Electrochemical Biosensor For Lactate Concentration Determination In Sweat","abstract":"The purpose of this research was to develop a novel electrochemical biosensor to measure lactate concentration in synthetic human sweat. The sensor is based on a nanocomposite material comprised of multi-walled carbon nanotubes (MWCNTs) and lactate oxidase (LOx) enzyme along with polypyrrole which are embedded on a flexible non-conductive nylon-6 (N-6) membrane. The carbon nanotubes allow the polymer membrane to behave as a conductive electrochemical electrode. Optimization showed that a MWCNT loading of 2.0 mg on a 14 weight percent of N-6 membrane functionalized with 50 µL of 100 IU LOx enzyme resulted in a highly sensitive and selective bio-membrane. This membrane exhibited the lowest over potential for lactate oxidation and had the lowest detection limit. The nanocomposites were characterized using Fourier Transform Infrared Spectroscopy (FTIR), which verified the attachment of both carboxyl groups and LOx to the respective carbon nanotube samples. Scanning electron microscopy (SEM) was used to analyze the structure of the sensors with and without the presence of the biomolecules. The sensitivity of the MWCNT-PPy-LOx nanobiocomposite with lactate was confirmed using cyclic voltammetry (CV) which distinguishably showed an oxidation peak compared to the control electrode. The sensitivity of the sensor was determined to be 3.33 µA/mM with a shelf-life of about 4 days.","abstract_html":"The purpose of this research was to develop a novel electrochemical biosensor to measure lactate concentration in synthetic human sweat. The sensor is based on a nanocomposite material comprised of multi-walled carbon nanotubes (MWCNTs) and lactate oxidase (LOx) enzyme along with polypyrrole which are embedded on a flexible non-conductive nylon-6 (N-6) membrane. The carbon nanotubes allow the polymer membrane to behave as a conductive electrochemical electrode. Optimization showed that a MWCNT loading of 2.0 mg on a 14 weight percent of N-6 membrane functionalized with 50 µL of 100 IU LOx enzyme resulted in a highly sensitive and selective bio-membrane. This membrane exhibited the lowest over potential for lactate oxidation and had the lowest detection limit. The nanocomposites were characterized using Fourier Transform Infrared Spectroscopy (FTIR), which verified the attachment of both carboxyl groups and LOx to the respective carbon nanotube samples. Scanning electron microscopy (SEM) was used to analyze the structure of the sensors with and without the presence of the biomolecules. The sensitivity of the MWCNT-PPy-LOx nanobiocomposite with lactate was confirmed using cyclic voltammetry (CV) which distinguishably showed an oxidation peak compared to the control electrode. The sensitivity of the sensor was determined to be 3.33 µA/mM with a shelf-life of about 4 days.","abstract_has_math":false,"creators":["Sarwar, Mysha"],"institution":"University of Akron","degree_name":"Master of Science in Engineering","degree_level":"masters","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Monty, Chelsea"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-06-13","date_published":"2016-06-13","updated_at":"2026-11-27T04:41:05Z","subjects":["Chemical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1464713357","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1464713357","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1464713357","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1464713357","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Monty, Chelsea"]},{"key":"dc:creator","label":"Author","values":["Sarwar, Mysha"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-06-13"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1464713357"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The purpose of this research was to develop a novel electrochemical biosensor to measure lactate concentration in synthetic human sweat. The sensor is based on a nanocomposite material comprised of multi-walled carbon nanotubes (MWCNTs) and lactate oxidase (LOx) enzyme along with polypyrrole which are embedded on a flexible non-conductive nylon-6 (N-6) membrane. The carbon nanotubes allow the polymer membrane to behave as a conductive electrochemical electrode. Optimization showed that a MWCNT loading of 2.0 mg on a 14 weight percent of N-6 membrane functionalized with 50 µL of 100 IU LOx enzyme resulted in a highly sensitive and selective bio-membrane. This membrane exhibited the lowest over potential for lactate oxidation and had the lowest detection limit. The nanocomposites were characterized using Fourier Transform Infrared Spectroscopy (FTIR), which verified the attachment of both carboxyl groups and LOx to the respective carbon nanotube samples. Scanning electron microscopy (SEM) was used to analyze the structure of the sensors with and without the presence of the biomolecules. The sensitivity of the MWCNT-PPy-LOx nanobiocomposite with lactate was confirmed using cyclic voltammetry (CV) which distinguishably showed an oxidation peak compared to the control electrode. The sensitivity of the sensor was determined to be 3.33 µA/mM with a shelf-life of about 4 days."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1.62 MB"]},{"key":"dc:title","label":"Title","values":["Development Of An Electrochemical Biosensor For Lactate Concentration Determination In Sweat"]}]}],"canonical_facts":{"dc:contributor.advisor":["Monty, Chelsea"],"dc:creator":["Sarwar, Mysha"],"dc:date":["2016-06-13"],"dc:description":["The purpose of this research was to develop a novel electrochemical biosensor to measure lactate concentration in synthetic human sweat. The sensor is based on a nanocomposite material comprised of multi-walled carbon nanotubes (MWCNTs) and lactate oxidase (LOx) enzyme along with polypyrrole which are embedded on a flexible non-conductive nylon-6 (N-6) membrane. The carbon nanotubes allow the polymer membrane to behave as a conductive electrochemical electrode. Optimization showed that a MWCNT loading of 2.0 mg on a 14 weight percent of N-6 membrane functionalized with 50 µL of 100 IU LOx enzyme resulted in a highly sensitive and selective bio-membrane. This membrane exhibited the lowest over potential for lactate oxidation and had the lowest detection limit. The nanocomposites were characterized using Fourier Transform Infrared Spectroscopy (FTIR), which verified the attachment of both carboxyl groups and LOx to the respective carbon nanotube samples. Scanning electron microscopy (SEM) was used to analyze the structure of the sensors with and without the presence of the biomolecules. The sensitivity of the MWCNT-PPy-LOx nanobiocomposite with lactate was confirmed using cyclic voltammetry (CV) which distinguishably showed an oxidation peak compared to the control electrode. The sensitivity of the sensor was determined to be 3.33 µA/mM with a shelf-life of about 4 days."],"dc:format":["application/pdf","1.62 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1464713357"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Chemical Engineering"],"dc:title":["Development Of An Electrochemical Biosensor For Lactate Concentration Determination In Sweat"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:41:05Z"}