{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1468852925"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1468852925","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Silk Based Porous Microneedle Array for Programmable Drug Delivery","abstract":"In this thesis, a novel microneedle device is introduced for vaccine delivery. The specific device was designed to have porous structure in order to obtain a dual drug release profile. This feature would enhance the efficiency of immunization as well as control the overall dosage. Two phase separation systems -- silk fibroin (SF) with poly(vinyl alcohol) (PVA) and SF with poly(ethylene oxide) (PEO) -- was employed to form the porous structure. All of these polymers have great biocompatibility and can be processed in aqueous solution. Phase behaviors were studied using film samples cast from mixtures of SF/PVA or SF/PEO aqueous solution, with different blending ratios. A fluorescent dye -- fluorescein isothiolcyanate (FITC) was conjugated to PVA for visualizing phase behavior. Bright field and fluorescent images were obtained under optic microscope. Island/sea morphology was found in SF/PVA system where PVA was located in islands, and inverse island/sea morphology was found in SF/PEO system. SF/PVA-PAA and SF/PEO-PAA composite microneedles were fabricated. Their structures were characterized by bright field and fluorescent microscopy, confocal microscopy, and/or scanning electron microscopy (SEM).The results revealed a significant trend of phase separation scale with respect to PVA or PEO content.Then an in vitro tip release test was done. The released tips from composite microneedle array showed to hold the geometry. As for the fabricated microneedles, the phase separated structure can be preserved in both microneedle tips. Pores were exposed after an incubation test of SF/PEO-PAA microneedle tips.The morphology of phase separated structure can be tuned from island/sea structure to bicontinuous structure, by increasing the portion of hydrophilic polymer. In island/sea structure, the inner islands are not exposed even after extraction of hydrophilic polymer. The drug release relies on diffusion through SF matrix. In bicontinuous structure, most hydrophilic polymer is extracted, and thus releases the drug faster. With their different mechanism of releasing, the releasing profile can be fine-tuned to meet the specific requirement.","abstract_html":"In this thesis, a novel microneedle device is introduced for vaccine delivery. The specific device was designed to have porous structure in order to obtain a dual drug release profile. This feature would enhance the efficiency of immunization as well as control the overall dosage. Two phase separation systems -- silk fibroin (SF) with poly(vinyl alcohol) (PVA) and SF with poly(ethylene oxide) (PEO) -- was employed to form the porous structure. All of these polymers have great biocompatibility and can be processed in aqueous solution. Phase behaviors were studied using film samples cast from mixtures of SF/PVA or SF/PEO aqueous solution, with different blending ratios. A fluorescent dye -- fluorescein isothiolcyanate (FITC) was conjugated to PVA for visualizing phase behavior. Bright field and fluorescent images were obtained under optic microscope. Island/sea morphology was found in SF/PVA system where PVA was located in islands, and inverse island/sea morphology was found in SF/PEO system. SF/PVA-PAA and SF/PEO-PAA composite microneedles were fabricated. Their structures were characterized by bright field and fluorescent microscopy, confocal microscopy, and/or scanning electron microscopy (SEM).The results revealed a significant trend of phase separation scale with respect to PVA or PEO content.Then an in vitro tip release test was done. The released tips from composite microneedle array showed to hold the geometry. As for the fabricated microneedles, the phase separated structure can be preserved in both microneedle tips. Pores were exposed after an incubation test of SF/PEO-PAA microneedle tips.The morphology of phase separated structure can be tuned from island/sea structure to bicontinuous structure, by increasing the portion of hydrophilic polymer. In island/sea structure, the inner islands are not exposed even after extraction of hydrophilic polymer. The drug release relies on diffusion through SF matrix. In bicontinuous structure, most hydrophilic polymer is extracted, and thus releases the drug faster. With their different mechanism of releasing, the releasing profile can be fine-tuned to meet the specific requirement.","abstract_has_math":false,"creators":["Zhao, Tianxin, Zhao"],"institution":"University of Akron","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Polymer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Min, Younjin"],"committee_chairs":["Kyu, Thein"],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-27T04:41:18Z","subjects":["Polymers","Biomedical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1468852925","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1468852925","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1468852925","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1468852925","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Min, Younjin"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Kyu, Thein"]},{"key":"dc:creator","label":"Author","values":["Zhao, Tianxin, Zhao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Polymer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Polymers","Biomedical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1468852925"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this thesis, a novel microneedle device is introduced for vaccine delivery. The specific device was designed to have porous structure in order to obtain a dual drug release profile. This feature would enhance the efficiency of immunization as well as control the overall dosage. Two phase separation systems -- silk fibroin (SF) with poly(vinyl alcohol) (PVA) and SF with poly(ethylene oxide) (PEO) -- was employed to form the porous structure. All of these polymers have great biocompatibility and can be processed in aqueous solution. Phase behaviors were studied using film samples cast from mixtures of SF/PVA or SF/PEO aqueous solution, with different blending ratios. A fluorescent dye -- fluorescein isothiolcyanate (FITC) was conjugated to PVA for visualizing phase behavior. Bright field and fluorescent images were obtained under optic microscope. Island/sea morphology was found in SF/PVA system where PVA was located in islands, and inverse island/sea morphology was found in SF/PEO system. SF/PVA-PAA and SF/PEO-PAA composite microneedles were fabricated. Their structures were characterized by bright field and fluorescent microscopy, confocal microscopy, and/or scanning electron microscopy (SEM).The results revealed a significant trend of phase separation scale with respect to PVA or PEO content.Then an in vitro tip release test was done. The released tips from composite microneedle array showed to hold the geometry. As for the fabricated microneedles, the phase separated structure can be preserved in both microneedle tips. Pores were exposed after an incubation test of SF/PEO-PAA microneedle tips.The morphology of phase separated structure can be tuned from island/sea structure to bicontinuous structure, by increasing the portion of hydrophilic polymer. In island/sea structure, the inner islands are not exposed even after extraction of hydrophilic polymer. The drug release relies on diffusion through SF matrix. In bicontinuous structure, most hydrophilic polymer is extracted, and thus releases the drug faster. With their different mechanism of releasing, the releasing profile can be fine-tuned to meet the specific requirement."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.53","27.81 MB"]},{"key":"dc:title","label":"Title","values":["Silk Based Porous Microneedle Array for Programmable Drug Delivery"]}]}],"canonical_facts":{"dc:contributor.advisor":["Min, Younjin"],"dc:contributor.committeechair":["Kyu, Thein"],"dc:creator":["Zhao, Tianxin, Zhao"],"dc:date":["2016"],"dc:description":["In this thesis, a novel microneedle device is introduced for vaccine delivery. The specific device was designed to have porous structure in order to obtain a dual drug release profile. This feature would enhance the efficiency of immunization as well as control the overall dosage. Two phase separation systems -- silk fibroin (SF) with poly(vinyl alcohol) (PVA) and SF with poly(ethylene oxide) (PEO) -- was employed to form the porous structure. All of these polymers have great biocompatibility and can be processed in aqueous solution. Phase behaviors were studied using film samples cast from mixtures of SF/PVA or SF/PEO aqueous solution, with different blending ratios. A fluorescent dye -- fluorescein isothiolcyanate (FITC) was conjugated to PVA for visualizing phase behavior. Bright field and fluorescent images were obtained under optic microscope. Island/sea morphology was found in SF/PVA system where PVA was located in islands, and inverse island/sea morphology was found in SF/PEO system. SF/PVA-PAA and SF/PEO-PAA composite microneedles were fabricated. Their structures were characterized by bright field and fluorescent microscopy, confocal microscopy, and/or scanning electron microscopy (SEM).The results revealed a significant trend of phase separation scale with respect to PVA or PEO content.Then an in vitro tip release test was done. The released tips from composite microneedle array showed to hold the geometry. As for the fabricated microneedles, the phase separated structure can be preserved in both microneedle tips. Pores were exposed after an incubation test of SF/PEO-PAA microneedle tips.The morphology of phase separated structure can be tuned from island/sea structure to bicontinuous structure, by increasing the portion of hydrophilic polymer. In island/sea structure, the inner islands are not exposed even after extraction of hydrophilic polymer. The drug release relies on diffusion through SF matrix. In bicontinuous structure, most hydrophilic polymer is extracted, and thus releases the drug faster. With their different mechanism of releasing, the releasing profile can be fine-tuned to meet the specific requirement."],"dc:format":["application/pdf","p.53","27.81 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1468852925"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Polymers","Biomedical Engineering"],"dc:title":["Silk Based Porous Microneedle Array for Programmable Drug Delivery"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Polymer Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:41:18Z"}