{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1472735633"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1472735633","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"HIGH-FREQUENCY IMPEDANCE CHARACTERISTICS AND HEALTH CONDITION MONITORING OF OVERHEAD POWER LINES","abstract":"In an age where functioning businesses are almost inconceivable in the absence of electric power, power interruption that can even last for a short period of time can cause tremendous losses of productivity, material, and revenue. Hence, electric power systems should be highly reliable. For reliable operation of power systems, continuous power line health monitoring should be conducted. By continuously monitoring the power lines, critical damages can be detected in their early stage of development. This allows appropriate measures to be applied on time; thereby improving the reliability of the power system while significantly reducing its maintenance costs.Overhead transmission lines are an intricate part of the power system, and their health condition is very important for reliable operation of the overall system. In this thesis, an approach to health monitoring of electric power lines using high frequency impedance characteristics is presented. This technique can detect faults in the power lines, and monitor their health condition. In order to identify damaged and faulty power lines, high-frequency impedance analysis is performed by observing the effects of damages and faults on the line impedance. A threshold value is set to determine if the power line needs replacement due to excessive damage. The proposed technique is verified through MatlabTM simulations and experimental tests. Here, three 28-foot long conductors are considered.","abstract_html":"In an age where functioning businesses are almost inconceivable in the absence of electric power, power interruption that can even last for a short period of time can cause tremendous losses of productivity, material, and revenue. Hence, electric power systems should be highly reliable. For reliable operation of power systems, continuous power line health monitoring should be conducted. By continuously monitoring the power lines, critical damages can be detected in their early stage of development. This allows appropriate measures to be applied on time; thereby improving the reliability of the power system while significantly reducing its maintenance costs.Overhead transmission lines are an intricate part of the power system, and their health condition is very important for reliable operation of the overall system. In this thesis, an approach to health monitoring of electric power lines using high frequency impedance characteristics is presented. This technique can detect faults in the power lines, and monitor their health condition. In order to identify damaged and faulty power lines, high-frequency impedance analysis is performed by observing the effects of damages and faults on the line impedance. A threshold value is set to determine if the power line needs replacement due to excessive damage. The proposed technique is verified through MatlabTM simulations and experimental tests. Here, three 28-foot long conductors are considered.","abstract_has_math":false,"creators":["Habtemariam, Filmon A."],"institution":"University of Akron","degree_name":"Master of Science in Engineering","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["De Abreu Garcia, J. Alexis"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-10-26","date_published":"2016-10-26","updated_at":"2026-11-27T04:41:25Z","subjects":["Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1472735633","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1472735633","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1472735633","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1472735633","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["De Abreu Garcia, J. Alexis"]},{"key":"dc:creator","label":"Author","values":["Habtemariam, Filmon A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-10-26"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1472735633"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In an age where functioning businesses are almost inconceivable in the absence of electric power, power interruption that can even last for a short period of time can cause tremendous losses of productivity, material, and revenue. Hence, electric power systems should be highly reliable. For reliable operation of power systems, continuous power line health monitoring should be conducted. By continuously monitoring the power lines, critical damages can be detected in their early stage of development. This allows appropriate measures to be applied on time; thereby improving the reliability of the power system while significantly reducing its maintenance costs.Overhead transmission lines are an intricate part of the power system, and their health condition is very important for reliable operation of the overall system. In this thesis, an approach to health monitoring of electric power lines using high frequency impedance characteristics is presented. This technique can detect faults in the power lines, and monitor their health condition. In order to identify damaged and faulty power lines, high-frequency impedance analysis is performed by observing the effects of damages and faults on the line impedance. A threshold value is set to determine if the power line needs replacement due to excessive damage. The proposed technique is verified through MatlabTM simulations and experimental tests. Here, three 28-foot long conductors are considered."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1.57 MB"]},{"key":"dc:title","label":"Title","values":["HIGH-FREQUENCY IMPEDANCE CHARACTERISTICS AND HEALTH CONDITION MONITORING OF OVERHEAD POWER LINES"]}]}],"canonical_facts":{"dc:contributor.advisor":["De Abreu Garcia, J. Alexis"],"dc:creator":["Habtemariam, Filmon A."],"dc:date":["2016-10-26"],"dc:description":["In an age where functioning businesses are almost inconceivable in the absence of electric power, power interruption that can even last for a short period of time can cause tremendous losses of productivity, material, and revenue. Hence, electric power systems should be highly reliable. For reliable operation of power systems, continuous power line health monitoring should be conducted. By continuously monitoring the power lines, critical damages can be detected in their early stage of development. This allows appropriate measures to be applied on time; thereby improving the reliability of the power system while significantly reducing its maintenance costs.Overhead transmission lines are an intricate part of the power system, and their health condition is very important for reliable operation of the overall system. In this thesis, an approach to health monitoring of electric power lines using high frequency impedance characteristics is presented. This technique can detect faults in the power lines, and monitor their health condition. In order to identify damaged and faulty power lines, high-frequency impedance analysis is performed by observing the effects of damages and faults on the line impedance. A threshold value is set to determine if the power line needs replacement due to excessive damage. The proposed technique is verified through MatlabTM simulations and experimental tests. Here, three 28-foot long conductors are considered."],"dc:format":["application/pdf","1.57 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1472735633"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering"],"dc:title":["HIGH-FREQUENCY IMPEDANCE CHARACTERISTICS AND HEALTH CONDITION MONITORING OF OVERHEAD POWER LINES"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:41:25Z"}