{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:akron1619183035472425"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:akron1619183035472425","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Optimizing Deposition of Matrix and Ionization Salt via Two-Step Sublimation in Sample Preparation for Surface-Layer Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Imaging (SL-MALDI-TOF MSI)","abstract":"Studying the surface behavior of polymers is crucial to improve many applications of polymers or enlarge the range of applications. Surface Layer Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Imaging (SL-MALDI-TOF MSI) is a novel technique based on the widely applied method of conventional MALDI mass spectrometry. Through SL-MALDI-TOF MSI, visualization of surfaces can be achieved. Moreover, this surface-specific technique can obtain the molecular composition of the surface layer, which we define as the layer within a few nanometers of the surface. Also, one can image the variation in this composition laterally across the surface. Previous research has proven that a two-step sublimation process of matrix and ionization salt is the best sample preparation for SL-MALDI MSI analysis. Nevertheless, the reproducibility and fidelity of the MALDI imaging still remain unsatisfying. From the preliminary investigations on the factors leading to nonuniform SL-MALDI-MSI signals from uniform film samples, it was concluded that the distributions of matrix and ionization salt in the chamber during sublimation are only two of the possible factors impacting uniformity, while thermal gradients were suspected to be a main factor causing the low fidelity. After eliminating thermal gradients from various aspects of the deposition process, the probability of obtaining a SL-MALDI image with high fidelity is greatly increased. However, the technique still suffers from low reproducibility and the occasional appearance of a secondary distribution in the mass spectra resulting from the salt clusters. A speculation is made suggesting that these limitations can be overcome potentially by using proper pretreatment for the ionization salt.","abstract_html":"Studying the surface behavior of polymers is crucial to improve many applications of polymers or enlarge the range of applications. Surface Layer Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Imaging (SL-MALDI-TOF MSI) is a novel technique based on the widely applied method of conventional MALDI mass spectrometry. Through SL-MALDI-TOF MSI, visualization of surfaces can be achieved. Moreover, this surface-specific technique can obtain the molecular composition of the surface layer, which we define as the layer within a few nanometers of the surface. Also, one can image the variation in this composition laterally across the surface. Previous research has proven that a two-step sublimation process of matrix and ionization salt is the best sample preparation for SL-MALDI MSI analysis. Nevertheless, the reproducibility and fidelity of the MALDI imaging still remain unsatisfying. From the preliminary investigations on the factors leading to nonuniform SL-MALDI-MSI signals from uniform film samples, it was concluded that the distributions of matrix and ionization salt in the chamber during sublimation are only two of the possible factors impacting uniformity, while thermal gradients were suspected to be a main factor causing the low fidelity. After eliminating thermal gradients from various aspects of the deposition process, the probability of obtaining a SL-MALDI image with high fidelity is greatly increased. However, the technique still suffers from low reproducibility and the occasional appearance of a secondary distribution in the mass spectra resulting from the salt clusters. A speculation is made suggesting that these limitations can be overcome potentially by using proper pretreatment for the ionization salt.","abstract_has_math":false,"creators":["Huang, Huan"],"institution":"University of Akron","degree_name":"Master of Science in Polymer Engineering","degree_level":"masters","degree_discipline":"Polymer Science","degree_department":null,"school":null,"contributors":[],"advisors":["Foster, Mark"],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-04-30","date_published":"2021-04-30","updated_at":"2026-11-27T04:50:14Z","subjects":["Polymers","Technology","Analytical Chemistry","Surface layer","MALDI MS imaging","Sublimation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1619183035472425","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=akron1619183035472425","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aakron1619183035472425","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aakron1619183035472425","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Foster, Mark"]},{"key":"dc:creator","label":"Author","values":["Huang, Huan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-04-30"]},{"key":"dc:publisher","label":"Institution","values":["University of Akron / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Polymer Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Polymer Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Akron"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Polymers","Technology","Analytical Chemistry","Surface layer","MALDI MS imaging","Sublimation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1619183035472425"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Studying the surface behavior of polymers is crucial to improve many applications of polymers or enlarge the range of applications. Surface Layer Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Imaging (SL-MALDI-TOF MSI) is a novel technique based on the widely applied method of conventional MALDI mass spectrometry. Through SL-MALDI-TOF MSI, visualization of surfaces can be achieved. Moreover, this surface-specific technique can obtain the molecular composition of the surface layer, which we define as the layer within a few nanometers of the surface. Also, one can image the variation in this composition laterally across the surface. Previous research has proven that a two-step sublimation process of matrix and ionization salt is the best sample preparation for SL-MALDI MSI analysis. Nevertheless, the reproducibility and fidelity of the MALDI imaging still remain unsatisfying. From the preliminary investigations on the factors leading to nonuniform SL-MALDI-MSI signals from uniform film samples, it was concluded that the distributions of matrix and ionization salt in the chamber during sublimation are only two of the possible factors impacting uniformity, while thermal gradients were suspected to be a main factor causing the low fidelity. After eliminating thermal gradients from various aspects of the deposition process, the probability of obtaining a SL-MALDI image with high fidelity is greatly increased. However, the technique still suffers from low reproducibility and the occasional appearance of a secondary distribution in the mass spectra resulting from the salt clusters. A speculation is made suggesting that these limitations can be overcome potentially by using proper pretreatment for the ionization salt."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.78","2.16 MB"]},{"key":"dc:title","label":"Title","values":["Optimizing Deposition of Matrix and Ionization Salt via Two-Step Sublimation in Sample Preparation for Surface-Layer Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Imaging (SL-MALDI-TOF MSI)"]}]}],"canonical_facts":{"dc:contributor.advisor":["Foster, Mark"],"dc:creator":["Huang, Huan"],"dc:date":["2021-04-30"],"dc:description":["Studying the surface behavior of polymers is crucial to improve many applications of polymers or enlarge the range of applications. Surface Layer Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Imaging (SL-MALDI-TOF MSI) is a novel technique based on the widely applied method of conventional MALDI mass spectrometry. Through SL-MALDI-TOF MSI, visualization of surfaces can be achieved. Moreover, this surface-specific technique can obtain the molecular composition of the surface layer, which we define as the layer within a few nanometers of the surface. Also, one can image the variation in this composition laterally across the surface. Previous research has proven that a two-step sublimation process of matrix and ionization salt is the best sample preparation for SL-MALDI MSI analysis. Nevertheless, the reproducibility and fidelity of the MALDI imaging still remain unsatisfying. From the preliminary investigations on the factors leading to nonuniform SL-MALDI-MSI signals from uniform film samples, it was concluded that the distributions of matrix and ionization salt in the chamber during sublimation are only two of the possible factors impacting uniformity, while thermal gradients were suspected to be a main factor causing the low fidelity. After eliminating thermal gradients from various aspects of the deposition process, the probability of obtaining a SL-MALDI image with high fidelity is greatly increased. However, the technique still suffers from low reproducibility and the occasional appearance of a secondary distribution in the mass spectra resulting from the salt clusters. A speculation is made suggesting that these limitations can be overcome potentially by using proper pretreatment for the ionization salt."],"dc:format":["application/pdf","p.78","2.16 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=akron1619183035472425"],"dc:language":["English"],"dc:publisher":["University of Akron / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Polymers","Technology","Analytical Chemistry","Surface layer","MALDI MS imaging","Sublimation"],"dc:title":["Optimizing Deposition of Matrix and Ionization Salt via Two-Step Sublimation in Sample Preparation for Surface-Layer Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Imaging (SL-MALDI-TOF MSI)"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Polymer Science"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Polymer Engineering"],"thesis:institution_name":["University of Akron"]},"updated_at":"2026-11-27T04:50:14Z"}