{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1054582569"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1054582569","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Development and breakdown of oxide scales on iron-25 percent chromium-20 percent nickel alloys in atmospheres containing oxygen and sulfur","abstract":"The corrosion behavior of Fe-25%Cr-20%Ni alloy has been studied in oxygen atmospheres as well as in mixed environments containing oxygen and sulfur. Pure oxidation has been carried out at 700°C and 900°C in 1 atm O<sub>2</sub> as well as in H<sub>2</sub>-H<sub>2</sub>O atmospheres of low oxygen partial pressures (at 700°C in a range of 10<sup>-31</sup> to 10<sup>-20</sup> atm and at 900°C in a range of 10<sup>-24</sup> to 10<sup>-20</sup> atm). In the early stages of oxidation at 700°C large amounts of Fe-rich oxide phases are formed on the alloy surface. They are mainly spinel phases, which are found to grow in an epitaxial relationship with the alloy. Because of the epitaxy and slow diffusion of chromium in the FCC alloy, it takes a long time for a complete chromia layer to become established at 700°C. Even after long exposure times the oxide scale still contains additional Fe-rich oxide phases. A chromia scale forms more rapidly on the Fe-25%Cr-20%Ni alloy at 900°C, although there are still areas where spinel phases exist on the alloy surface. Corrosion of the Fe-25%Cr-20%Ni alloy in environments containing oxygen and sulfur of varying partial pressures has been i nvestigated at 700°C in H<sub>2</sub>-H<sub>2</sub>O-H<sub>2</sub>S atmospheres. Protective chromia scales are practically never established under these conditions and exposure causes catastrophic corrosion leading to overall sulfidation of the metal. Preoxidation of Fe-25%Cr-20%Ni alloy at 700°C before exposing it to mixed gases atmosphere slightly retards the corrosion process, but rapid breakaway of the oxide scales follows. This is believed to take place because of the presence of Fe-rich phases in the pre-formed oxide scale. Oxide scales formed at 900°C are more protective against sulfur attack. Most of the alloy surface which is covered by chromia remains unaffected after exposure to mixed gases. The spinel phases which are still present in some areas after the preoxidation process, however, act as \"weak spots\" and lead to breakaway of the scale.","abstract_html":"The corrosion behavior of Fe-25%Cr-20%Ni alloy has been studied in oxygen atmospheres as well as in mixed environments containing oxygen and sulfur. Pure oxidation has been carried out at 700°C and 900°C in 1 atm O&lt;sub&gt;2&lt;/sub&gt; as well as in H&lt;sub&gt;2&lt;/sub&gt;-H&lt;sub&gt;2&lt;/sub&gt;O atmospheres of low oxygen partial pressures (at 700°C in a range of 10&lt;sup&gt;-31&lt;/sup&gt; to 10&lt;sup&gt;-20&lt;/sup&gt; atm and at 900°C in a range of 10&lt;sup&gt;-24&lt;/sup&gt; to 10&lt;sup&gt;-20&lt;/sup&gt; atm). In the early stages of oxidation at 700°C large amounts of Fe-rich oxide phases are formed on the alloy surface. They are mainly spinel phases, which are found to grow in an epitaxial relationship with the alloy. Because of the epitaxy and slow diffusion of chromium in the FCC alloy, it takes a long time for a complete chromia layer to become established at 700°C. Even after long exposure times the oxide scale still contains additional Fe-rich oxide phases. A chromia scale forms more rapidly on the Fe-25%Cr-20%Ni alloy at 900°C, although there are still areas where spinel phases exist on the alloy surface. Corrosion of the Fe-25%Cr-20%Ni alloy in environments containing oxygen and sulfur of varying partial pressures has been i nvestigated at 700°C in H&lt;sub&gt;2&lt;/sub&gt;-H&lt;sub&gt;2&lt;/sub&gt;O-H&lt;sub&gt;2&lt;/sub&gt;S atmospheres. Protective chromia scales are practically never established under these conditions and exposure causes catastrophic corrosion leading to overall sulfidation of the metal. Preoxidation of Fe-25%Cr-20%Ni alloy at 700°C before exposing it to mixed gases atmosphere slightly retards the corrosion process, but rapid breakaway of the oxide scales follows. This is believed to take place because of the presence of Fe-rich phases in the pre-formed oxide scale. Oxide scales formed at 900°C are more protective against sulfur attack. Most of the alloy surface which is covered by chromia remains unaffected after exposure to mixed gases. The spinel phases which are still present in some areas after the preoxidation process, however, act as &quot;weak spots&quot; and lead to breakaway of the scale.","abstract_has_math":false,"creators":["Grobis, Iwona Marta"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Materials Science and Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Vedula, K."],"committee_chairs":[],"committee_members":[],"year":1990,"date_issued":"1990","date_published":"1990","updated_at":"2026-11-27T04:14:08Z","subjects":["breakdown oxide scales iron-25 percent chromium-20 nickel alloys atmospheres oxygen sulfur"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1054582569","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1054582569","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1054582569","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1054582569","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Vedula, K."]},{"key":"dc:creator","label":"Author","values":["Grobis, Iwona Marta"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1990"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Science and Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["breakdown oxide scales iron-25 percent chromium-20 nickel alloys atmospheres oxygen sulfur"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1054582569"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The corrosion behavior of Fe-25%Cr-20%Ni alloy has been studied in oxygen atmospheres as well as in mixed environments containing oxygen and sulfur. Pure oxidation has been carried out at 700°C and 900°C in 1 atm O<sub>2</sub> as well as in H<sub>2</sub>-H<sub>2</sub>O atmospheres of low oxygen partial pressures (at 700°C in a range of 10<sup>-31</sup> to 10<sup>-20</sup> atm and at 900°C in a range of 10<sup>-24</sup> to 10<sup>-20</sup> atm). In the early stages of oxidation at 700°C large amounts of Fe-rich oxide phases are formed on the alloy surface. They are mainly spinel phases, which are found to grow in an epitaxial relationship with the alloy. Because of the epitaxy and slow diffusion of chromium in the FCC alloy, it takes a long time for a complete chromia layer to become established at 700°C. Even after long exposure times the oxide scale still contains additional Fe-rich oxide phases. A chromia scale forms more rapidly on the Fe-25%Cr-20%Ni alloy at 900°C, although there are still areas where spinel phases exist on the alloy surface. Corrosion of the Fe-25%Cr-20%Ni alloy in environments containing oxygen and sulfur of varying partial pressures has been i nvestigated at 700°C in H<sub>2</sub>-H<sub>2</sub>O-H<sub>2</sub>S atmospheres. Protective chromia scales are practically never established under these conditions and exposure causes catastrophic corrosion leading to overall sulfidation of the metal. Preoxidation of Fe-25%Cr-20%Ni alloy at 700°C before exposing it to mixed gases atmosphere slightly retards the corrosion process, but rapid breakaway of the oxide scales follows. This is believed to take place because of the presence of Fe-rich phases in the pre-formed oxide scale. Oxide scales formed at 900°C are more protective against sulfur attack. Most of the alloy surface which is covered by chromia remains unaffected after exposure to mixed gases. The spinel phases which are still present in some areas after the preoxidation process, however, act as \"weak spots\" and lead to breakaway of the scale."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.290","6.3 MB"]},{"key":"dc:title","label":"Title","values":["Development and breakdown of oxide scales on iron-25 percent chromium-20 percent nickel alloys in atmospheres containing oxygen and sulfur"]}]}],"canonical_facts":{"dc:contributor.advisor":["Vedula, K."],"dc:creator":["Grobis, Iwona Marta"],"dc:date":["1990"],"dc:description":["The corrosion behavior of Fe-25%Cr-20%Ni alloy has been studied in oxygen atmospheres as well as in mixed environments containing oxygen and sulfur. Pure oxidation has been carried out at 700°C and 900°C in 1 atm O<sub>2</sub> as well as in H<sub>2</sub>-H<sub>2</sub>O atmospheres of low oxygen partial pressures (at 700°C in a range of 10<sup>-31</sup> to 10<sup>-20</sup> atm and at 900°C in a range of 10<sup>-24</sup> to 10<sup>-20</sup> atm). In the early stages of oxidation at 700°C large amounts of Fe-rich oxide phases are formed on the alloy surface. They are mainly spinel phases, which are found to grow in an epitaxial relationship with the alloy. Because of the epitaxy and slow diffusion of chromium in the FCC alloy, it takes a long time for a complete chromia layer to become established at 700°C. Even after long exposure times the oxide scale still contains additional Fe-rich oxide phases. A chromia scale forms more rapidly on the Fe-25%Cr-20%Ni alloy at 900°C, although there are still areas where spinel phases exist on the alloy surface. Corrosion of the Fe-25%Cr-20%Ni alloy in environments containing oxygen and sulfur of varying partial pressures has been i nvestigated at 700°C in H<sub>2</sub>-H<sub>2</sub>O-H<sub>2</sub>S atmospheres. Protective chromia scales are practically never established under these conditions and exposure causes catastrophic corrosion leading to overall sulfidation of the metal. Preoxidation of Fe-25%Cr-20%Ni alloy at 700°C before exposing it to mixed gases atmosphere slightly retards the corrosion process, but rapid breakaway of the oxide scales follows. This is believed to take place because of the presence of Fe-rich phases in the pre-formed oxide scale. Oxide scales formed at 900°C are more protective against sulfur attack. Most of the alloy surface which is covered by chromia remains unaffected after exposure to mixed gases. The spinel phases which are still present in some areas after the preoxidation process, however, act as \"weak spots\" and lead to breakaway of the scale."],"dc:format":["application/pdf","p.290","6.3 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1054582569"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["breakdown oxide scales iron-25 percent chromium-20 nickel alloys atmospheres oxygen sulfur"],"dc:title":["Development and breakdown of oxide scales on iron-25 percent chromium-20 percent nickel alloys in atmospheres containing oxygen and sulfur"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Materials Science and Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:08Z"}