{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1055526549"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1055526549","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Gradient and rf coil issues in magnetic resonance imaging","abstract":"Techniques are presented for new analysis of coils in magnetic resonance imaging that should lead to faster and more accurate pictures of humans. Insertable planar, cylindrical or elliptical gradient coils offer the potential for significant performance increases in magnetic resonance imaging. Using variational methods to minimize inductance and thereby optimize switching speeds, we have analyzed coils with these three geometries. In the interest of improving image quality by reducing eddy current artifacts, the same methods are used to design a set of self-shielded gradient coils. In the cylindrical and planar cases, scale models of the new coils have been constructed and tested. In the elliptical case, the theory and mathematics necessary to design elliptic gradient coils is presented. This includes the development of a Green function expansion in elliptic cylinder coordinates. The expansion is in terms of cosine-elliptic and Mathieu functions. Improvements in the field uniformity of rf coils results in improved image quality in magnetic resonance imaging. Using a waveguide structure instead of traditional coil designs leads to the possibility of generating more uniform fields at higher frequencies. A new conformal transformation is developed in order to an alyze TEM excitations of microstrips and coupled microstrips with circular and elliptical cross-sections. This new transformation is derived by expressing a Schwarz-Christoffel transformation in terms of elliptic integrals of the first and third kind. Exact solutions for the complex potential of these geometries are presented for the first time. The uniformity of the magnetic field inside slotted tube transmission lines is examined using the newly developed conformal mapping technique. The degree to which the transmission lines with elliptical cross-sections provide more uniform magnetic fields than those with the circular cross-sections is investigated.","abstract_html":"Techniques are presented for new analysis of coils in magnetic resonance imaging that should lead to faster and more accurate pictures of humans. Insertable planar, cylindrical or elliptical gradient coils offer the potential for significant performance increases in magnetic resonance imaging. Using variational methods to minimize inductance and thereby optimize switching speeds, we have analyzed coils with these three geometries. In the interest of improving image quality by reducing eddy current artifacts, the same methods are used to design a set of self-shielded gradient coils. In the cylindrical and planar cases, scale models of the new coils have been constructed and tested. In the elliptical case, the theory and mathematics necessary to design elliptic gradient coils is presented. This includes the development of a Green function expansion in elliptic cylinder coordinates. The expansion is in terms of cosine-elliptic and Mathieu functions. Improvements in the field uniformity of rf coils results in improved image quality in magnetic resonance imaging. Using a waveguide structure instead of traditional coil designs leads to the possibility of generating more uniform fields at higher frequencies. A new conformal transformation is developed in order to an alyze TEM excitations of microstrips and coupled microstrips with circular and elliptical cross-sections. This new transformation is derived by expressing a Schwarz-Christoffel transformation in terms of elliptic integrals of the first and third kind. Exact solutions for the complex potential of these geometries are presented for the first time. The uniformity of the magnetic field inside slotted tube transmission lines is examined using the newly developed conformal mapping technique. The degree to which the transmission lines with elliptical cross-sections provide more uniform magnetic fields than those with the circular cross-sections is investigated.","abstract_has_math":false,"creators":["Martens, Michael Alan"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":["Brown, Robert"],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991","date_published":"1991","updated_at":"2026-11-27T04:14:08Z","subjects":["Gradient rf coil issues magnetic resonance imaging"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1055526549","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1055526549","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1055526549","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1055526549","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brown, Robert"]},{"key":"dc:creator","label":"Author","values":["Martens, Michael Alan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1991"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Gradient rf coil issues magnetic resonance imaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1055526549"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Techniques are presented for new analysis of coils in magnetic resonance imaging that should lead to faster and more accurate pictures of humans. Insertable planar, cylindrical or elliptical gradient coils offer the potential for significant performance increases in magnetic resonance imaging. Using variational methods to minimize inductance and thereby optimize switching speeds, we have analyzed coils with these three geometries. In the interest of improving image quality by reducing eddy current artifacts, the same methods are used to design a set of self-shielded gradient coils. In the cylindrical and planar cases, scale models of the new coils have been constructed and tested. In the elliptical case, the theory and mathematics necessary to design elliptic gradient coils is presented. This includes the development of a Green function expansion in elliptic cylinder coordinates. The expansion is in terms of cosine-elliptic and Mathieu functions. Improvements in the field uniformity of rf coils results in improved image quality in magnetic resonance imaging. Using a waveguide structure instead of traditional coil designs leads to the possibility of generating more uniform fields at higher frequencies. A new conformal transformation is developed in order to an alyze TEM excitations of microstrips and coupled microstrips with circular and elliptical cross-sections. This new transformation is derived by expressing a Schwarz-Christoffel transformation in terms of elliptic integrals of the first and third kind. Exact solutions for the complex potential of these geometries are presented for the first time. The uniformity of the magnetic field inside slotted tube transmission lines is examined using the newly developed conformal mapping technique. The degree to which the transmission lines with elliptical cross-sections provide more uniform magnetic fields than those with the circular cross-sections is investigated."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.181","3.98 MB"]},{"key":"dc:title","label":"Title","values":["Gradient and rf coil issues in magnetic resonance imaging"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brown, Robert"],"dc:creator":["Martens, Michael Alan"],"dc:date":["1991"],"dc:description":["Techniques are presented for new analysis of coils in magnetic resonance imaging that should lead to faster and more accurate pictures of humans. Insertable planar, cylindrical or elliptical gradient coils offer the potential for significant performance increases in magnetic resonance imaging. Using variational methods to minimize inductance and thereby optimize switching speeds, we have analyzed coils with these three geometries. In the interest of improving image quality by reducing eddy current artifacts, the same methods are used to design a set of self-shielded gradient coils. In the cylindrical and planar cases, scale models of the new coils have been constructed and tested. In the elliptical case, the theory and mathematics necessary to design elliptic gradient coils is presented. This includes the development of a Green function expansion in elliptic cylinder coordinates. The expansion is in terms of cosine-elliptic and Mathieu functions. Improvements in the field uniformity of rf coils results in improved image quality in magnetic resonance imaging. Using a waveguide structure instead of traditional coil designs leads to the possibility of generating more uniform fields at higher frequencies. A new conformal transformation is developed in order to an alyze TEM excitations of microstrips and coupled microstrips with circular and elliptical cross-sections. This new transformation is derived by expressing a Schwarz-Christoffel transformation in terms of elliptic integrals of the first and third kind. Exact solutions for the complex potential of these geometries are presented for the first time. The uniformity of the magnetic field inside slotted tube transmission lines is examined using the newly developed conformal mapping technique. The degree to which the transmission lines with elliptical cross-sections provide more uniform magnetic fields than those with the circular cross-sections is investigated."],"dc:format":["application/pdf","p.181","3.98 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1055526549"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Gradient rf coil issues magnetic resonance imaging"],"dc:title":["Gradient and rf coil issues in magnetic resonance imaging"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:08Z"}