{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1056045062"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1056045062","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Development of enzyme electrodes for anaerobic glucose monitoring incorporating a polymeric redox mediator","abstract":"An electrochemical oxidation process has been developed to fabricate enzyme electrodes, immobilized with glucose oxidase (GOx) and a polymeric mediator poly(vinylferrocene) (PVFc). The ferrocene moiety of PVFc successfully transfers electrons between the GOx and the electrode surface; and the macromolecular nature of PVFc helps minimize the loss of small mediator molecules. Enzyme electrodes fabricated by this process respond rapidly to glucose, with steady-state currents achieved in less than 10 seconds. Current responses to glucose concentrations were investigated under different operation conditions such as pH, temperature, oxygen, and anion interference. A mathematical model describing the steady-state amperometric operation of the enzyme electrode has been derived. Reaction steps include diffusion, heterogeneous enzymatic catalysis, electron mediation, and electrochemical regeneration of mediators. Simplified equations corresponding to certain kinetic characteristics are presented. Each case shows its unique relationship between the inverse current and the inverse analyte concentration. Therefore, a diagnostic plot of inverse current versus inverse analyte concentration allows rate limiting step(s) to be identified immediately. Experimental data obtained from known systems confirm the validity of this model. Various techniques were employed to characterize the electrochemical and electrocatalytic properties of the PVFc/GOx films. The non-symmetrical cyclic voltammograms of the PVFc/GOx film indicate that the electrochemical reactions are not reversible. The thickness of the PVFc/GOx films were measured by a profilometer to be from submicrons to a few microns. These values are significantly larger than those estimated from the oxidation charges, based on Faraday's law. Spectral properties of this film were acquired by UV/visible and FTIR spectroscopies. The FTIR spectra of the enzyme electrode surfaces show stronger absorption features attributed to those of GOx rather than those of PVFc. This is due partly to a spectral change of PVFc after it has been oxidized. The redox change of the surface PVFc at different applied potentials was traced by correlating FTIR spectra with the electrochemical charges. Enzymatic activity of enzyme electrodes were independently quantified employing a spectrophotometric coupled-enzyme assay and a Rotating-Disk-Electrode assay. About 35% of the enzyme molecules immobilized stay active.","abstract_html":"An electrochemical oxidation process has been developed to fabricate enzyme electrodes, immobilized with glucose oxidase (GOx) and a polymeric mediator poly(vinylferrocene) (PVFc). The ferrocene moiety of PVFc successfully transfers electrons between the GOx and the electrode surface; and the macromolecular nature of PVFc helps minimize the loss of small mediator molecules. Enzyme electrodes fabricated by this process respond rapidly to glucose, with steady-state currents achieved in less than 10 seconds. Current responses to glucose concentrations were investigated under different operation conditions such as pH, temperature, oxygen, and anion interference. A mathematical model describing the steady-state amperometric operation of the enzyme electrode has been derived. Reaction steps include diffusion, heterogeneous enzymatic catalysis, electron mediation, and electrochemical regeneration of mediators. Simplified equations corresponding to certain kinetic characteristics are presented. Each case shows its unique relationship between the inverse current and the inverse analyte concentration. Therefore, a diagnostic plot of inverse current versus inverse analyte concentration allows rate limiting step(s) to be identified immediately. Experimental data obtained from known systems confirm the validity of this model. Various techniques were employed to characterize the electrochemical and electrocatalytic properties of the PVFc/GOx films. The non-symmetrical cyclic voltammograms of the PVFc/GOx film indicate that the electrochemical reactions are not reversible. The thickness of the PVFc/GOx films were measured by a profilometer to be from submicrons to a few microns. These values are significantly larger than those estimated from the oxidation charges, based on Faraday&#x27;s law. Spectral properties of this film were acquired by UV/visible and FTIR spectroscopies. The FTIR spectra of the enzyme electrode surfaces show stronger absorption features attributed to those of GOx rather than those of PVFc. This is due partly to a spectral change of PVFc after it has been oxidized. The redox change of the surface PVFc at different applied potentials was traced by correlating FTIR spectra with the electrochemical charges. Enzymatic activity of enzyme electrodes were independently quantified employing a spectrophotometric coupled-enzyme assay and a Rotating-Disk-Electrode assay. About 35% of the enzyme molecules immobilized stay active.","abstract_has_math":false,"creators":["Chen, Chi Jin"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Savinell, Robert"],"committee_chairs":[],"committee_members":[],"year":1992,"date_issued":"1992","date_published":"1992","updated_at":"2026-11-27T04:14:13Z","subjects":["Development enzyme electrodes anaerobic glucose monitoring incorporating polymeric redox mediator"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1056045062","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1056045062","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1056045062","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1056045062","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Savinell, Robert"]},{"key":"dc:creator","label":"Author","values":["Chen, Chi Jin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1992"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Development enzyme electrodes anaerobic glucose monitoring incorporating polymeric redox mediator"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1056045062"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["An electrochemical oxidation process has been developed to fabricate enzyme electrodes, immobilized with glucose oxidase (GOx) and a polymeric mediator poly(vinylferrocene) (PVFc). The ferrocene moiety of PVFc successfully transfers electrons between the GOx and the electrode surface; and the macromolecular nature of PVFc helps minimize the loss of small mediator molecules. Enzyme electrodes fabricated by this process respond rapidly to glucose, with steady-state currents achieved in less than 10 seconds. Current responses to glucose concentrations were investigated under different operation conditions such as pH, temperature, oxygen, and anion interference. A mathematical model describing the steady-state amperometric operation of the enzyme electrode has been derived. Reaction steps include diffusion, heterogeneous enzymatic catalysis, electron mediation, and electrochemical regeneration of mediators. Simplified equations corresponding to certain kinetic characteristics are presented. Each case shows its unique relationship between the inverse current and the inverse analyte concentration. Therefore, a diagnostic plot of inverse current versus inverse analyte concentration allows rate limiting step(s) to be identified immediately. Experimental data obtained from known systems confirm the validity of this model. Various techniques were employed to characterize the electrochemical and electrocatalytic properties of the PVFc/GOx films. The non-symmetrical cyclic voltammograms of the PVFc/GOx film indicate that the electrochemical reactions are not reversible. The thickness of the PVFc/GOx films were measured by a profilometer to be from submicrons to a few microns. These values are significantly larger than those estimated from the oxidation charges, based on Faraday's law. Spectral properties of this film were acquired by UV/visible and FTIR spectroscopies. The FTIR spectra of the enzyme electrode surfaces show stronger absorption features attributed to those of GOx rather than those of PVFc. This is due partly to a spectral change of PVFc after it has been oxidized. The redox change of the surface PVFc at different applied potentials was traced by correlating FTIR spectra with the electrochemical charges. Enzymatic activity of enzyme electrodes were independently quantified employing a spectrophotometric coupled-enzyme assay and a Rotating-Disk-Electrode assay. About 35% of the enzyme molecules immobilized stay active."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.173","3.91 MB"]},{"key":"dc:title","label":"Title","values":["Development of enzyme electrodes for anaerobic glucose monitoring incorporating a polymeric redox mediator"]}]}],"canonical_facts":{"dc:contributor.advisor":["Savinell, Robert"],"dc:creator":["Chen, Chi Jin"],"dc:date":["1992"],"dc:description":["An electrochemical oxidation process has been developed to fabricate enzyme electrodes, immobilized with glucose oxidase (GOx) and a polymeric mediator poly(vinylferrocene) (PVFc). The ferrocene moiety of PVFc successfully transfers electrons between the GOx and the electrode surface; and the macromolecular nature of PVFc helps minimize the loss of small mediator molecules. Enzyme electrodes fabricated by this process respond rapidly to glucose, with steady-state currents achieved in less than 10 seconds. Current responses to glucose concentrations were investigated under different operation conditions such as pH, temperature, oxygen, and anion interference. A mathematical model describing the steady-state amperometric operation of the enzyme electrode has been derived. Reaction steps include diffusion, heterogeneous enzymatic catalysis, electron mediation, and electrochemical regeneration of mediators. Simplified equations corresponding to certain kinetic characteristics are presented. Each case shows its unique relationship between the inverse current and the inverse analyte concentration. Therefore, a diagnostic plot of inverse current versus inverse analyte concentration allows rate limiting step(s) to be identified immediately. Experimental data obtained from known systems confirm the validity of this model. Various techniques were employed to characterize the electrochemical and electrocatalytic properties of the PVFc/GOx films. The non-symmetrical cyclic voltammograms of the PVFc/GOx film indicate that the electrochemical reactions are not reversible. The thickness of the PVFc/GOx films were measured by a profilometer to be from submicrons to a few microns. These values are significantly larger than those estimated from the oxidation charges, based on Faraday's law. Spectral properties of this film were acquired by UV/visible and FTIR spectroscopies. The FTIR spectra of the enzyme electrode surfaces show stronger absorption features attributed to those of GOx rather than those of PVFc. This is due partly to a spectral change of PVFc after it has been oxidized. The redox change of the surface PVFc at different applied potentials was traced by correlating FTIR spectra with the electrochemical charges. Enzymatic activity of enzyme electrodes were independently quantified employing a spectrophotometric coupled-enzyme assay and a Rotating-Disk-Electrode assay. About 35% of the enzyme molecules immobilized stay active."],"dc:format":["application/pdf","p.173","3.91 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1056045062"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Development enzyme electrodes anaerobic glucose monitoring incorporating polymeric redox mediator"],"dc:title":["Development of enzyme electrodes for anaerobic glucose monitoring incorporating a polymeric redox mediator"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:13Z"}