{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1056557546"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1056557546","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Mechanical studies of the intramuscular electrode leads","abstract":"The intramuscular electrode lead (made by the multi-strand wire) is used for functional electrical stimulation. In this investigation of the electrode, the biomedical origin has been abstraction into mechanical problems. It is important to understand the studies only focus the mechanical behavior of the electrode, therefore, the applications of the studies are limited. The studies illustrate the quality of the electrode is mainly judged by its flexibility and longevity which are functions of the mechanical properties of the electrode and loading conditions. The mechanical properties of the electrode largely depend on the strand wire manufacturing process and the geometric configuration of the electrode. The residual stress which is a \"by-product\" from winding process largely affected the electrodes' fatigue life. Although the size of the double helix electrode is more than twice of the single helix electrode, it still becomes the best choice in terms of it's flexibility and life expectancy, both of which were proven by experiments and patient implantation.","abstract_html":"The intramuscular electrode lead (made by the multi-strand wire) is used for functional electrical stimulation. In this investigation of the electrode, the biomedical origin has been abstraction into mechanical problems. It is important to understand the studies only focus the mechanical behavior of the electrode, therefore, the applications of the studies are limited. The studies illustrate the quality of the electrode is mainly judged by its flexibility and longevity which are functions of the mechanical properties of the electrode and loading conditions. The mechanical properties of the electrode largely depend on the strand wire manufacturing process and the geometric configuration of the electrode. The residual stress which is a &quot;by-product&quot; from winding process largely affected the electrodes&#x27; fatigue life. Although the size of the double helix electrode is more than twice of the single helix electrode, it still becomes the best choice in terms of it&#x27;s flexibility and life expectancy, both of which were proven by experiments and patient implantation.","abstract_has_math":false,"creators":["Fu, Shuzhen"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Kicher, Thomas"],"committee_chairs":[],"committee_members":[],"year":1992,"date_issued":"1992","date_published":"1992","updated_at":"2026-11-27T04:14:13Z","subjects":["Mechanical studies intramuscular electrode leads"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1056557546","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1056557546","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1056557546","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1056557546","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kicher, Thomas"]},{"key":"dc:creator","label":"Author","values":["Fu, Shuzhen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1992"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical studies intramuscular electrode leads"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1056557546"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The intramuscular electrode lead (made by the multi-strand wire) is used for functional electrical stimulation. In this investigation of the electrode, the biomedical origin has been abstraction into mechanical problems. It is important to understand the studies only focus the mechanical behavior of the electrode, therefore, the applications of the studies are limited. The studies illustrate the quality of the electrode is mainly judged by its flexibility and longevity which are functions of the mechanical properties of the electrode and loading conditions. The mechanical properties of the electrode largely depend on the strand wire manufacturing process and the geometric configuration of the electrode. The residual stress which is a \"by-product\" from winding process largely affected the electrodes' fatigue life. Although the size of the double helix electrode is more than twice of the single helix electrode, it still becomes the best choice in terms of it's flexibility and life expectancy, both of which were proven by experiments and patient implantation."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.133","2.23 MB"]},{"key":"dc:title","label":"Title","values":["Mechanical studies of the intramuscular electrode leads"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kicher, Thomas"],"dc:creator":["Fu, Shuzhen"],"dc:date":["1992"],"dc:description":["The intramuscular electrode lead (made by the multi-strand wire) is used for functional electrical stimulation. In this investigation of the electrode, the biomedical origin has been abstraction into mechanical problems. It is important to understand the studies only focus the mechanical behavior of the electrode, therefore, the applications of the studies are limited. The studies illustrate the quality of the electrode is mainly judged by its flexibility and longevity which are functions of the mechanical properties of the electrode and loading conditions. The mechanical properties of the electrode largely depend on the strand wire manufacturing process and the geometric configuration of the electrode. The residual stress which is a \"by-product\" from winding process largely affected the electrodes' fatigue life. Although the size of the double helix electrode is more than twice of the single helix electrode, it still becomes the best choice in terms of it's flexibility and life expectancy, both of which were proven by experiments and patient implantation."],"dc:format":["application/pdf","p.133","2.23 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1056557546"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical studies intramuscular electrode leads"],"dc:title":["Mechanical studies of the intramuscular electrode leads"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:13Z"}