{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1056745410"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1056745410","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Development of a solid polymer electrolyte sensor for transcutaneous oxygen monitoring","abstract":"Transcutaneous oxygen tension (tcPO<sub>2</sub>) measurement is important in clinic practices. The commercial tcPO<sub>2</sub> sensors have the disadvantages of instability and structural complexity. To overcome these problems, a flexible solid polymer electrolyte (SPE) electrochemical oxygen sensor was developed. The sensor consisted of a Nafion membrane with three thin film metal (gold or platinum) electrodes. The Nafion served as the substrate and the electrolyte, and the metal films functioned as catalyst and gas diffusional barrier. A diffusion-controlled limiting current was used to quantify the oxygen concentration. A flexible planar Au-Nafion sensor was first constructed. The sensor characteristics were investigated under various operation conditions such as relative humidity, temperature, CV scan rate and electrode pre-polarization potential. A linear relationship between the limiting current and oxygen concentration existed in the oxygen range of 0-21 mole % with a current of 8-100 μA. A 90% response time was 14 sec. The sensor showed good performance for operating in a cyclic voltammetric mode. However, steady-state operation was hindered by the technical problems of limited reaction sites and weak adhesion at the gold-Nafion interface.","abstract_html":"Transcutaneous oxygen tension (tcPO&lt;sub&gt;2&lt;/sub&gt;) measurement is important in clinic practices. The commercial tcPO&lt;sub&gt;2&lt;/sub&gt; sensors have the disadvantages of instability and structural complexity. To overcome these problems, a flexible solid polymer electrolyte (SPE) electrochemical oxygen sensor was developed. The sensor consisted of a Nafion membrane with three thin film metal (gold or platinum) electrodes. The Nafion served as the substrate and the electrolyte, and the metal films functioned as catalyst and gas diffusional barrier. A diffusion-controlled limiting current was used to quantify the oxygen concentration. A flexible planar Au-Nafion sensor was first constructed. The sensor characteristics were investigated under various operation conditions such as relative humidity, temperature, CV scan rate and electrode pre-polarization potential. A linear relationship between the limiting current and oxygen concentration existed in the oxygen range of 0-21 mole % with a current of 8-100 μA. A 90% response time was 14 sec. The sensor showed good performance for operating in a cyclic voltammetric mode. However, steady-state operation was hindered by the technical problems of limited reaction sites and weak adhesion at the gold-Nafion interface.","abstract_has_math":false,"creators":["Peng, Wei"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Liu, Chung-Chiun"],"committee_chairs":[],"committee_members":[],"year":1993,"date_issued":"1993","date_published":"1993","updated_at":"2026-11-27T04:14:13Z","subjects":["Engineering, Chemical","solid polymer electrolyte sensor transcutaneous oxygen monitoring"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1056745410","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1056745410","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1056745410","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1056745410","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Liu, Chung-Chiun"]},{"key":"dc:creator","label":"Author","values":["Peng, Wei"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1993"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Chemical","solid polymer electrolyte sensor transcutaneous oxygen monitoring"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1056745410"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Transcutaneous oxygen tension (tcPO<sub>2</sub>) measurement is important in clinic practices. The commercial tcPO<sub>2</sub> sensors have the disadvantages of instability and structural complexity. To overcome these problems, a flexible solid polymer electrolyte (SPE) electrochemical oxygen sensor was developed. The sensor consisted of a Nafion membrane with three thin film metal (gold or platinum) electrodes. The Nafion served as the substrate and the electrolyte, and the metal films functioned as catalyst and gas diffusional barrier. A diffusion-controlled limiting current was used to quantify the oxygen concentration. A flexible planar Au-Nafion sensor was first constructed. The sensor characteristics were investigated under various operation conditions such as relative humidity, temperature, CV scan rate and electrode pre-polarization potential. A linear relationship between the limiting current and oxygen concentration existed in the oxygen range of 0-21 mole % with a current of 8-100 μA. A 90% response time was 14 sec. The sensor showed good performance for operating in a cyclic voltammetric mode. However, steady-state operation was hindered by the technical problems of limited reaction sites and weak adhesion at the gold-Nafion interface."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","4.49 MB"]},{"key":"dc:title","label":"Title","values":["Development of a solid polymer electrolyte sensor for transcutaneous oxygen monitoring"]}]}],"canonical_facts":{"dc:contributor.advisor":["Liu, Chung-Chiun"],"dc:creator":["Peng, Wei"],"dc:date":["1993"],"dc:description":["Transcutaneous oxygen tension (tcPO<sub>2</sub>) measurement is important in clinic practices. The commercial tcPO<sub>2</sub> sensors have the disadvantages of instability and structural complexity. To overcome these problems, a flexible solid polymer electrolyte (SPE) electrochemical oxygen sensor was developed. The sensor consisted of a Nafion membrane with three thin film metal (gold or platinum) electrodes. The Nafion served as the substrate and the electrolyte, and the metal films functioned as catalyst and gas diffusional barrier. A diffusion-controlled limiting current was used to quantify the oxygen concentration. A flexible planar Au-Nafion sensor was first constructed. The sensor characteristics were investigated under various operation conditions such as relative humidity, temperature, CV scan rate and electrode pre-polarization potential. A linear relationship between the limiting current and oxygen concentration existed in the oxygen range of 0-21 mole % with a current of 8-100 μA. A 90% response time was 14 sec. The sensor showed good performance for operating in a cyclic voltammetric mode. However, steady-state operation was hindered by the technical problems of limited reaction sites and weak adhesion at the gold-Nafion interface."],"dc:format":["application/pdf","4.49 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1056745410"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Chemical","solid polymer electrolyte sensor transcutaneous oxygen monitoring"],"dc:title":["Development of a solid polymer electrolyte sensor for transcutaneous oxygen monitoring"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:13Z"}