{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1056746257"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1056746257","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Recovery of endocardial potentials from intracavitary potential data","abstract":"Understanding the mechanism of the cardiac arrhythmia is paramount to the selection of an appropriate method for its management. The objective of this project is to develop and test a mathematical method to reconstruct the endocardial potentials from potential data measured with an intracavitary multielectrode probe (the \"inverse problem\"). Initially, an idealized mathematical model of the probe-heart-torso volume conductor was developed to study the effects of variations in conductive and geometric parameters on endocardial and intracavitary potentials. The mathematical formulation was then developed and applied to the reconstruction of endocardial potentials from actual intracavitary probe potential data obtained from isolated, perfused canine left ventricles. Data were acquired during rhythms induced by electrical stimuli applied at different locations and varying depths within the myocardium. Endocardial potentials were measured using multielectrode intramural needles, for evaluating the accuracy of the inverse solutions. Endocardial potentials provide an accurate reflection of the underlying cardiac source configuration; the corresponding intracavitary probe potentials exhibit a smoothed-out, low-amplitude distribution. Left ventricular wall pacing gives rise to a potential minimum on the probe surface, facing the region of stimulation. Inversely-computed end ocardial potentials, from measured probe potentials, give a good \"image\" of the major features (regions of negative and positive potentials) as compared to the measured endocardial potentials. During early activation, the computed endocardial potentials exhibit a potential minimum in close proximity to the pacing site, predicting the location of the stimulus with good accuracy (within 10 mm error). Multiple stimuli, as close as 10-20 mm to each other, can be distinguished and localized to their sites of origin by the inverse procedure. The spatial distribution of the computed endocardial potentials reflects the underlying cardiac fiber direction. Maps of isochrones show good correspondence between the isochrones determined from the computed endocardial potentials and those determined from the measured endocardial potentials. The approach presented here could provide information on the nature of conduction abnormalities, site of origin and type of arrhythmias, pathway of reentrant activity, location and size of infarcted regions, and effects of drugs in the clinical cardiac electrophysiology laboratory and in the intact experimental animal.","abstract_html":"Understanding the mechanism of the cardiac arrhythmia is paramount to the selection of an appropriate method for its management. The objective of this project is to develop and test a mathematical method to reconstruct the endocardial potentials from potential data measured with an intracavitary multielectrode probe (the &quot;inverse problem&quot;). Initially, an idealized mathematical model of the probe-heart-torso volume conductor was developed to study the effects of variations in conductive and geometric parameters on endocardial and intracavitary potentials. The mathematical formulation was then developed and applied to the reconstruction of endocardial potentials from actual intracavitary probe potential data obtained from isolated, perfused canine left ventricles. Data were acquired during rhythms induced by electrical stimuli applied at different locations and varying depths within the myocardium. Endocardial potentials were measured using multielectrode intramural needles, for evaluating the accuracy of the inverse solutions. Endocardial potentials provide an accurate reflection of the underlying cardiac source configuration; the corresponding intracavitary probe potentials exhibit a smoothed-out, low-amplitude distribution. Left ventricular wall pacing gives rise to a potential minimum on the probe surface, facing the region of stimulation. Inversely-computed end ocardial potentials, from measured probe potentials, give a good &quot;image&quot; of the major features (regions of negative and positive potentials) as compared to the measured endocardial potentials. During early activation, the computed endocardial potentials exhibit a potential minimum in close proximity to the pacing site, predicting the location of the stimulus with good accuracy (within 10 mm error). Multiple stimuli, as close as 10-20 mm to each other, can be distinguished and localized to their sites of origin by the inverse procedure. The spatial distribution of the computed endocardial potentials reflects the underlying cardiac fiber direction. Maps of isochrones show good correspondence between the isochrones determined from the computed endocardial potentials and those determined from the measured endocardial potentials. The approach presented here could provide information on the nature of conduction abnormalities, site of origin and type of arrhythmias, pathway of reentrant activity, location and size of infarcted regions, and effects of drugs in the clinical cardiac electrophysiology laboratory and in the intact experimental animal.","abstract_has_math":false,"creators":["Khoury, Dirar Shafiq"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["n/a, n/a"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1993,"date_issued":"1993","date_published":"1993","updated_at":"2026-11-26T03:16:04Z","subjects":["Engineering, Biomedical","endocardial intracavitary"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1056746257","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1056746257","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1056746257","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1056746257","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["n/a, n/a"]},{"key":"dc:creator","label":"Author","values":["Khoury, Dirar Shafiq"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1993"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Biomedical","endocardial intracavitary"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1056746257"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Understanding the mechanism of the cardiac arrhythmia is paramount to the selection of an appropriate method for its management. The objective of this project is to develop and test a mathematical method to reconstruct the endocardial potentials from potential data measured with an intracavitary multielectrode probe (the \"inverse problem\"). Initially, an idealized mathematical model of the probe-heart-torso volume conductor was developed to study the effects of variations in conductive and geometric parameters on endocardial and intracavitary potentials. The mathematical formulation was then developed and applied to the reconstruction of endocardial potentials from actual intracavitary probe potential data obtained from isolated, perfused canine left ventricles. Data were acquired during rhythms induced by electrical stimuli applied at different locations and varying depths within the myocardium. Endocardial potentials were measured using multielectrode intramural needles, for evaluating the accuracy of the inverse solutions. Endocardial potentials provide an accurate reflection of the underlying cardiac source configuration; the corresponding intracavitary probe potentials exhibit a smoothed-out, low-amplitude distribution. Left ventricular wall pacing gives rise to a potential minimum on the probe surface, facing the region of stimulation. Inversely-computed end ocardial potentials, from measured probe potentials, give a good \"image\" of the major features (regions of negative and positive potentials) as compared to the measured endocardial potentials. During early activation, the computed endocardial potentials exhibit a potential minimum in close proximity to the pacing site, predicting the location of the stimulus with good accuracy (within 10 mm error). Multiple stimuli, as close as 10-20 mm to each other, can be distinguished and localized to their sites of origin by the inverse procedure. The spatial distribution of the computed endocardial potentials reflects the underlying cardiac fiber direction. Maps of isochrones show good correspondence between the isochrones determined from the computed endocardial potentials and those determined from the measured endocardial potentials. The approach presented here could provide information on the nature of conduction abnormalities, site of origin and type of arrhythmias, pathway of reentrant activity, location and size of infarcted regions, and effects of drugs in the clinical cardiac electrophysiology laboratory and in the intact experimental animal."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.183","4.99 MB"]},{"key":"dc:title","label":"Title","values":["Recovery of endocardial potentials from intracavitary potential data"]}]}],"canonical_facts":{"dc:contributor":["n/a, n/a"],"dc:creator":["Khoury, Dirar Shafiq"],"dc:date":["1993"],"dc:description":["Understanding the mechanism of the cardiac arrhythmia is paramount to the selection of an appropriate method for its management. The objective of this project is to develop and test a mathematical method to reconstruct the endocardial potentials from potential data measured with an intracavitary multielectrode probe (the \"inverse problem\"). Initially, an idealized mathematical model of the probe-heart-torso volume conductor was developed to study the effects of variations in conductive and geometric parameters on endocardial and intracavitary potentials. The mathematical formulation was then developed and applied to the reconstruction of endocardial potentials from actual intracavitary probe potential data obtained from isolated, perfused canine left ventricles. Data were acquired during rhythms induced by electrical stimuli applied at different locations and varying depths within the myocardium. Endocardial potentials were measured using multielectrode intramural needles, for evaluating the accuracy of the inverse solutions. Endocardial potentials provide an accurate reflection of the underlying cardiac source configuration; the corresponding intracavitary probe potentials exhibit a smoothed-out, low-amplitude distribution. Left ventricular wall pacing gives rise to a potential minimum on the probe surface, facing the region of stimulation. Inversely-computed end ocardial potentials, from measured probe potentials, give a good \"image\" of the major features (regions of negative and positive potentials) as compared to the measured endocardial potentials. During early activation, the computed endocardial potentials exhibit a potential minimum in close proximity to the pacing site, predicting the location of the stimulus with good accuracy (within 10 mm error). Multiple stimuli, as close as 10-20 mm to each other, can be distinguished and localized to their sites of origin by the inverse procedure. The spatial distribution of the computed endocardial potentials reflects the underlying cardiac fiber direction. Maps of isochrones show good correspondence between the isochrones determined from the computed endocardial potentials and those determined from the measured endocardial potentials. The approach presented here could provide information on the nature of conduction abnormalities, site of origin and type of arrhythmias, pathway of reentrant activity, location and size of infarcted regions, and effects of drugs in the clinical cardiac electrophysiology laboratory and in the intact experimental animal."],"dc:format":["application/pdf","p.183","4.99 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1056746257"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Biomedical","endocardial intracavitary"],"dc:title":["Recovery of endocardial potentials from intracavitary potential data"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:16:04Z"}