{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1057155289"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1057155289","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"MRI susceptometry: Theory and robustness of an external phantom method for measuring bulk susceptibility from MRI field echo phase reconstruction maps applied to human liver iron overload","abstract":"A novel method for estimating the susceptibility of an object using the MRI field distortions in an external reference water bath next to the object is described. The field measurement is obtained using a MRI phase reconstruction from a Gradient Echo scan. A field model of an arbitrary object in a static magnetic field is discretely calculated using a Fourier convolution method from geometry determined from the magnitude reconstruction. Least squares estimation then yields the susceptibility of the object. Required (and proven) assumptions include; superposition, object homogeneity, negligible higher order field terms, field model accuracy, geometrical model accuracy and correlation of MRI FE phase to field distortion. MRI susceptometry estimation of in vitro phantoms yielded susceptibility estimates which correlated well with known values (r > 0.9975). This external reference bath MRI susceptometry method could be used to quantitate iron levels in iron overload patients. The errors which may occur in MRI susceptometry include field noise, and model errors including; outline error, outline shift, compartment inhomogeneity, volume error and unmodeled sources of field distort ion. Ultimately, the model errors can all be treated as unmodeled sources. Simulations and in vitro studies indicate that expected levels of field noise will not reduce the efficacy of the susceptibility estimations. However, unmodeled sources with relative strengths on the order of an unmodeled lung to a modeled liver of normal iron levels will reduce the efficacy of the fit (for a 22 patient in vivo experiment, r < 0.6). Filter application will alter the noise model, and improve the fit. Additionally, choosing the data set which lies closest to the organ of interest (i.e. the liver) will also improve the fit. With filtering and data set restriction, the estimates of the in vivo patient data were improved (r > 0.85). However, correlation of only the normal and low-level iron overload patients was not improved (r < 0.5).","abstract_html":"A novel method for estimating the susceptibility of an object using the MRI field distortions in an external reference water bath next to the object is described. The field measurement is obtained using a MRI phase reconstruction from a Gradient Echo scan. A field model of an arbitrary object in a static magnetic field is discretely calculated using a Fourier convolution method from geometry determined from the magnitude reconstruction. Least squares estimation then yields the susceptibility of the object. Required (and proven) assumptions include; superposition, object homogeneity, negligible higher order field terms, field model accuracy, geometrical model accuracy and correlation of MRI FE phase to field distortion. MRI susceptometry estimation of in vitro phantoms yielded susceptibility estimates which correlated well with known values (r &gt; 0.9975). This external reference bath MRI susceptometry method could be used to quantitate iron levels in iron overload patients. The errors which may occur in MRI susceptometry include field noise, and model errors including; outline error, outline shift, compartment inhomogeneity, volume error and unmodeled sources of field distort ion. Ultimately, the model errors can all be treated as unmodeled sources. Simulations and in vitro studies indicate that expected levels of field noise will not reduce the efficacy of the susceptibility estimations. However, unmodeled sources with relative strengths on the order of an unmodeled lung to a modeled liver of normal iron levels will reduce the efficacy of the fit (for a 22 patient in vivo experiment, r &lt; 0.6). Filter application will alter the noise model, and improve the fit. Additionally, choosing the data set which lies closest to the organ of interest (i.e. the liver) will also improve the fit. With filtering and data set restriction, the estimates of the in vivo patient data were improved (r &gt; 0.85). However, correlation of only the normal and low-level iron overload patients was not improved (r &lt; 0.5).","abstract_has_math":false,"creators":["Holt, Randall William"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Diaz, Pedro"],"committee_chairs":[],"committee_members":[],"year":1993,"date_issued":"1993","date_published":"1993","updated_at":"2026-11-27T04:14:13Z","subjects":["MRI susceptometry","external phantom method","measuring bulk susceptibility","MRI field echo phase","reconstruction maps","human liver","iron overload"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1057155289","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1057155289","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1057155289","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1057155289","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Diaz, Pedro"]},{"key":"dc:creator","label":"Author","values":["Holt, Randall William"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1993"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["MRI susceptometry","external phantom method","measuring bulk susceptibility","MRI field echo phase","reconstruction maps","human liver","iron overload"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1057155289"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A novel method for estimating the susceptibility of an object using the MRI field distortions in an external reference water bath next to the object is described. The field measurement is obtained using a MRI phase reconstruction from a Gradient Echo scan. A field model of an arbitrary object in a static magnetic field is discretely calculated using a Fourier convolution method from geometry determined from the magnitude reconstruction. Least squares estimation then yields the susceptibility of the object. Required (and proven) assumptions include; superposition, object homogeneity, negligible higher order field terms, field model accuracy, geometrical model accuracy and correlation of MRI FE phase to field distortion. MRI susceptometry estimation of in vitro phantoms yielded susceptibility estimates which correlated well with known values (r > 0.9975). This external reference bath MRI susceptometry method could be used to quantitate iron levels in iron overload patients. The errors which may occur in MRI susceptometry include field noise, and model errors including; outline error, outline shift, compartment inhomogeneity, volume error and unmodeled sources of field distort ion. Ultimately, the model errors can all be treated as unmodeled sources. Simulations and in vitro studies indicate that expected levels of field noise will not reduce the efficacy of the susceptibility estimations. However, unmodeled sources with relative strengths on the order of an unmodeled lung to a modeled liver of normal iron levels will reduce the efficacy of the fit (for a 22 patient in vivo experiment, r < 0.6). Filter application will alter the noise model, and improve the fit. Additionally, choosing the data set which lies closest to the organ of interest (i.e. the liver) will also improve the fit. With filtering and data set restriction, the estimates of the in vivo patient data were improved (r > 0.85). However, correlation of only the normal and low-level iron overload patients was not improved (r < 0.5)."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.325","8.6 MB"]},{"key":"dc:title","label":"Title","values":["MRI susceptometry: Theory and robustness of an external phantom method for measuring bulk susceptibility from MRI field echo phase reconstruction maps applied to human liver iron overload"]}]}],"canonical_facts":{"dc:contributor.advisor":["Diaz, Pedro"],"dc:creator":["Holt, Randall William"],"dc:date":["1993"],"dc:description":["A novel method for estimating the susceptibility of an object using the MRI field distortions in an external reference water bath next to the object is described. The field measurement is obtained using a MRI phase reconstruction from a Gradient Echo scan. A field model of an arbitrary object in a static magnetic field is discretely calculated using a Fourier convolution method from geometry determined from the magnitude reconstruction. Least squares estimation then yields the susceptibility of the object. Required (and proven) assumptions include; superposition, object homogeneity, negligible higher order field terms, field model accuracy, geometrical model accuracy and correlation of MRI FE phase to field distortion. MRI susceptometry estimation of in vitro phantoms yielded susceptibility estimates which correlated well with known values (r > 0.9975). This external reference bath MRI susceptometry method could be used to quantitate iron levels in iron overload patients. The errors which may occur in MRI susceptometry include field noise, and model errors including; outline error, outline shift, compartment inhomogeneity, volume error and unmodeled sources of field distort ion. Ultimately, the model errors can all be treated as unmodeled sources. Simulations and in vitro studies indicate that expected levels of field noise will not reduce the efficacy of the susceptibility estimations. However, unmodeled sources with relative strengths on the order of an unmodeled lung to a modeled liver of normal iron levels will reduce the efficacy of the fit (for a 22 patient in vivo experiment, r < 0.6). Filter application will alter the noise model, and improve the fit. Additionally, choosing the data set which lies closest to the organ of interest (i.e. the liver) will also improve the fit. With filtering and data set restriction, the estimates of the in vivo patient data were improved (r > 0.85). However, correlation of only the normal and low-level iron overload patients was not improved (r < 0.5)."],"dc:format":["application/pdf","p.325","8.6 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1057155289"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["MRI susceptometry","external phantom method","measuring bulk susceptibility","MRI field echo phase","reconstruction maps","human liver","iron overload"],"dc:title":["MRI susceptometry: Theory and robustness of an external phantom method for measuring bulk susceptibility from MRI field echo phase reconstruction maps applied to human liver iron overload"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:13Z"}