{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1057599486"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1057599486","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A study of oscillatory thermocapillary convection in circular containers with carbon dioxide laser heating","abstract":"Oscillatory thermocapillary convection in small circular containers heated at the center of the free surface with CO<sub>2</sub> laser is studied by investigating the various onset conditions. The effect of container dimensions, aspect ratios and heating zone ratios as well as the effect of viscosity are investigated. The onset of unsteady state is determined by observing the flow structures with flow visualization and the temperature distributions with a thermocouple probe and an I.R. imager. It is observed that when the input heat flux is increased beyond a certain limit, a distinctive unsteady flow pattern appears. This unsteady phenomenon is identified as oscillatory thermocapillary and is similar in flow structure to the constant temperature case studied earlier where the fluid was heated by a Nichrome wire along the container axis. The factors involved in the cause of the oscillations are presented. Silicone oils with 2cSt and 5cSt kinematic viscosity are used as the test fluids. To supplement the experimental work a numerical analysis of steady thermocapillary flow is also conducted.","abstract_html":"Oscillatory thermocapillary convection in small circular containers heated at the center of the free surface with CO&lt;sub&gt;2&lt;/sub&gt; laser is studied by investigating the various onset conditions. The effect of container dimensions, aspect ratios and heating zone ratios as well as the effect of viscosity are investigated. The onset of unsteady state is determined by observing the flow structures with flow visualization and the temperature distributions with a thermocouple probe and an I.R. imager. It is observed that when the input heat flux is increased beyond a certain limit, a distinctive unsteady flow pattern appears. This unsteady phenomenon is identified as oscillatory thermocapillary and is similar in flow structure to the constant temperature case studied earlier where the fluid was heated by a Nichrome wire along the container axis. The factors involved in the cause of the oscillations are presented. Silicone oils with 2cSt and 5cSt kinematic viscosity are used as the test fluids. To supplement the experimental work a numerical analysis of steady thermocapillary flow is also conducted.","abstract_has_math":false,"creators":["Lee, Jung Hyun"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Ostrach, Simon"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1994,"date_issued":"1994","date_published":"1994","updated_at":"2026-11-26T03:16:17Z","subjects":["oscillatory thermocapillary","convection","circular containers","carbon dioxide","laser heating"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1057599486","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1057599486","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1057599486","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1057599486","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ostrach, Simon"]},{"key":"dc:creator","label":"Author","values":["Lee, Jung Hyun"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1994"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["oscillatory thermocapillary","convection","circular containers","carbon dioxide","laser heating"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1057599486"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Oscillatory thermocapillary convection in small circular containers heated at the center of the free surface with CO<sub>2</sub> laser is studied by investigating the various onset conditions. The effect of container dimensions, aspect ratios and heating zone ratios as well as the effect of viscosity are investigated. The onset of unsteady state is determined by observing the flow structures with flow visualization and the temperature distributions with a thermocouple probe and an I.R. imager. It is observed that when the input heat flux is increased beyond a certain limit, a distinctive unsteady flow pattern appears. This unsteady phenomenon is identified as oscillatory thermocapillary and is similar in flow structure to the constant temperature case studied earlier where the fluid was heated by a Nichrome wire along the container axis. The factors involved in the cause of the oscillations are presented. Silicone oils with 2cSt and 5cSt kinematic viscosity are used as the test fluids. To supplement the experimental work a numerical analysis of steady thermocapillary flow is also conducted."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.145","2.78 MB"]},{"key":"dc:title","label":"Title","values":["A study of oscillatory thermocapillary convection in circular containers with carbon dioxide laser heating"]}]}],"canonical_facts":{"dc:contributor":["Ostrach, Simon"],"dc:creator":["Lee, Jung Hyun"],"dc:date":["1994"],"dc:description":["Oscillatory thermocapillary convection in small circular containers heated at the center of the free surface with CO<sub>2</sub> laser is studied by investigating the various onset conditions. The effect of container dimensions, aspect ratios and heating zone ratios as well as the effect of viscosity are investigated. The onset of unsteady state is determined by observing the flow structures with flow visualization and the temperature distributions with a thermocouple probe and an I.R. imager. It is observed that when the input heat flux is increased beyond a certain limit, a distinctive unsteady flow pattern appears. This unsteady phenomenon is identified as oscillatory thermocapillary and is similar in flow structure to the constant temperature case studied earlier where the fluid was heated by a Nichrome wire along the container axis. The factors involved in the cause of the oscillations are presented. Silicone oils with 2cSt and 5cSt kinematic viscosity are used as the test fluids. To supplement the experimental work a numerical analysis of steady thermocapillary flow is also conducted."],"dc:format":["application/pdf","p.145","2.78 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1057599486"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["oscillatory thermocapillary","convection","circular containers","carbon dioxide","laser heating"],"dc:title":["A study of oscillatory thermocapillary convection in circular containers with carbon dioxide laser heating"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:16:17Z"}