{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1057677172"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1057677172","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Volumetric intracoronary ultrasound","abstract":"Three dimensional analysis using intracoronary ultrasound (ICUS) pull-back data provides the unique ability to quantitate lumen and atherosclerotic plaque volumes. Unlike x-ray angiography which measures only the lumen, ICUS provides direct information about plaque volume distribution. ICUS volumetric analysis is required in order to understand mechanisms of coronary interventions, restenosis, and regression. In this study we developed and validated volumetric ICUS methodology. In the first part of the study, optimal data acquisition parameters for volumetric acquisition were established using simulations on computer phantoms of stenotic arteries. Eleven computer phantoms were generated using cross-sectional area data from quantitative angiography of stenotic coronary arteries. Three methods of data acquisition were simulated: conventional manual pull-back; motorized pull-back; and manual pull-back with measured displacement. Effects of pull-back velocity and cardiac gating on cross-sectional area profiles and volumes were studied. We rated the methods, measured ~ motorized >> manual. Cardiac gating eliminated errors introduced by vessel deformation within a cardiac cycle. With cardiac gating, pull-backs with mean velocities up to 1.2 mm/sec allowed reconstruction of cross-sectional area profiles within 5% RMS error. With faster pull-backs, cardiac gating resulted in sparse spatial samp ling and significant errors in cross-sectional area profiles. The accuracy of both motorized and measured required equal displacements of the catheter proximal and distal ends. This assumption was validated with in-vitro experiments where x-ray fluoroscopy was used to measure the displacement of the imaging tip. Excellent correlation was found between the two displacements (r = 0.99). Finally, slow pull-backs were performed by 3 operators, and pull-back velocities were measured. It was found that mean pull-back velocities as low as 0.8 mm/sec were achievable. In the second part of the study, we developed a real-time, ICUS pull-back data acquisition scheme to acquire calibrated, cardiac-gated 3D image data sets. A semi-automated border detection scheme was implemented using dynamic programming. To validate the ICUS methodology, multiple pull-backs were performed in phantoms. ICUS volumes were very reproducible (~3% standard deviation) and were close to independently obtained volume measurements obtained from water weight (mean error ~5%). The ICUS volumes also correlated with angiographic analysis which is the current gold standard in coronary imaging (mean error ~1.6%). Clinical applicability was assessed by performing 10 cardiac gated pull-backs in 5 patients before and after directional coronary atherectomy (DCA). Lumen and plaque volumes over the length of the DCA cutter showed that lumen volume improvement occurred due to plaque removal (45%) and vessel expansion (55%). Angiographic measurements of lumen volumes compared favorably. We conclude that volumetric ICUS provides accurate and reproducible estimates and, unlike angiography, provides a direct in-vivo technique for quantifying atherosclerotic plaque volumes. The technique will have direct clinical applicability in regression and restenosis trails.","abstract_html":"Three dimensional analysis using intracoronary ultrasound (ICUS) pull-back data provides the unique ability to quantitate lumen and atherosclerotic plaque volumes. Unlike x-ray angiography which measures only the lumen, ICUS provides direct information about plaque volume distribution. ICUS volumetric analysis is required in order to understand mechanisms of coronary interventions, restenosis, and regression. In this study we developed and validated volumetric ICUS methodology. In the first part of the study, optimal data acquisition parameters for volumetric acquisition were established using simulations on computer phantoms of stenotic arteries. Eleven computer phantoms were generated using cross-sectional area data from quantitative angiography of stenotic coronary arteries. Three methods of data acquisition were simulated: conventional manual pull-back; motorized pull-back; and manual pull-back with measured displacement. Effects of pull-back velocity and cardiac gating on cross-sectional area profiles and volumes were studied. We rated the methods, measured ~ motorized &gt;&gt; manual. Cardiac gating eliminated errors introduced by vessel deformation within a cardiac cycle. With cardiac gating, pull-backs with mean velocities up to 1.2 mm/sec allowed reconstruction of cross-sectional area profiles within 5% RMS error. With faster pull-backs, cardiac gating resulted in sparse spatial samp ling and significant errors in cross-sectional area profiles. The accuracy of both motorized and measured required equal displacements of the catheter proximal and distal ends. This assumption was validated with in-vitro experiments where x-ray fluoroscopy was used to measure the displacement of the imaging tip. Excellent correlation was found between the two displacements (r = 0.99). Finally, slow pull-backs were performed by 3 operators, and pull-back velocities were measured. It was found that mean pull-back velocities as low as 0.8 mm/sec were achievable. In the second part of the study, we developed a real-time, ICUS pull-back data acquisition scheme to acquire calibrated, cardiac-gated 3D image data sets. A semi-automated border detection scheme was implemented using dynamic programming. To validate the ICUS methodology, multiple pull-backs were performed in phantoms. ICUS volumes were very reproducible (~3% standard deviation) and were close to independently obtained volume measurements obtained from water weight (mean error ~5%). The ICUS volumes also correlated with angiographic analysis which is the current gold standard in coronary imaging (mean error ~1.6%). Clinical applicability was assessed by performing 10 cardiac gated pull-backs in 5 patients before and after directional coronary atherectomy (DCA). Lumen and plaque volumes over the length of the DCA cutter showed that lumen volume improvement occurred due to plaque removal (45%) and vessel expansion (55%). Angiographic measurements of lumen volumes compared favorably. We conclude that volumetric ICUS provides accurate and reproducible estimates and, unlike angiography, provides a direct in-vivo technique for quantifying atherosclerotic plaque volumes. The technique will have direct clinical applicability in regression and restenosis trails.","abstract_has_math":false,"creators":["Dhawale, Paritosh Jayant"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["n/a, n/a"],"committee_chairs":[],"committee_members":[],"year":1994,"date_issued":"1994","date_published":"1994","updated_at":"2026-11-27T04:14:13Z","subjects":["Engineering, Biomedical","Volumetric intracoronary ultrasound."],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1057677172","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1057677172","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1057677172","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1057677172","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["n/a, n/a"]},{"key":"dc:creator","label":"Author","values":["Dhawale, Paritosh Jayant"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1994"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Biomedical","Volumetric intracoronary ultrasound."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1057677172"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Three dimensional analysis using intracoronary ultrasound (ICUS) pull-back data provides the unique ability to quantitate lumen and atherosclerotic plaque volumes. Unlike x-ray angiography which measures only the lumen, ICUS provides direct information about plaque volume distribution. ICUS volumetric analysis is required in order to understand mechanisms of coronary interventions, restenosis, and regression. In this study we developed and validated volumetric ICUS methodology. In the first part of the study, optimal data acquisition parameters for volumetric acquisition were established using simulations on computer phantoms of stenotic arteries. Eleven computer phantoms were generated using cross-sectional area data from quantitative angiography of stenotic coronary arteries. Three methods of data acquisition were simulated: conventional manual pull-back; motorized pull-back; and manual pull-back with measured displacement. Effects of pull-back velocity and cardiac gating on cross-sectional area profiles and volumes were studied. We rated the methods, measured ~ motorized >> manual. Cardiac gating eliminated errors introduced by vessel deformation within a cardiac cycle. With cardiac gating, pull-backs with mean velocities up to 1.2 mm/sec allowed reconstruction of cross-sectional area profiles within 5% RMS error. With faster pull-backs, cardiac gating resulted in sparse spatial samp ling and significant errors in cross-sectional area profiles. The accuracy of both motorized and measured required equal displacements of the catheter proximal and distal ends. This assumption was validated with in-vitro experiments where x-ray fluoroscopy was used to measure the displacement of the imaging tip. Excellent correlation was found between the two displacements (r = 0.99). Finally, slow pull-backs were performed by 3 operators, and pull-back velocities were measured. It was found that mean pull-back velocities as low as 0.8 mm/sec were achievable. In the second part of the study, we developed a real-time, ICUS pull-back data acquisition scheme to acquire calibrated, cardiac-gated 3D image data sets. A semi-automated border detection scheme was implemented using dynamic programming. To validate the ICUS methodology, multiple pull-backs were performed in phantoms. ICUS volumes were very reproducible (~3% standard deviation) and were close to independently obtained volume measurements obtained from water weight (mean error ~5%). The ICUS volumes also correlated with angiographic analysis which is the current gold standard in coronary imaging (mean error ~1.6%). Clinical applicability was assessed by performing 10 cardiac gated pull-backs in 5 patients before and after directional coronary atherectomy (DCA). Lumen and plaque volumes over the length of the DCA cutter showed that lumen volume improvement occurred due to plaque removal (45%) and vessel expansion (55%). Angiographic measurements of lumen volumes compared favorably. We conclude that volumetric ICUS provides accurate and reproducible estimates and, unlike angiography, provides a direct in-vivo technique for quantifying atherosclerotic plaque volumes. The technique will have direct clinical applicability in regression and restenosis trails."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.169","4.18 MB"]},{"key":"dc:title","label":"Title","values":["Volumetric intracoronary ultrasound"]}]}],"canonical_facts":{"dc:contributor.advisor":["n/a, n/a"],"dc:creator":["Dhawale, Paritosh Jayant"],"dc:date":["1994"],"dc:description":["Three dimensional analysis using intracoronary ultrasound (ICUS) pull-back data provides the unique ability to quantitate lumen and atherosclerotic plaque volumes. Unlike x-ray angiography which measures only the lumen, ICUS provides direct information about plaque volume distribution. ICUS volumetric analysis is required in order to understand mechanisms of coronary interventions, restenosis, and regression. In this study we developed and validated volumetric ICUS methodology. In the first part of the study, optimal data acquisition parameters for volumetric acquisition were established using simulations on computer phantoms of stenotic arteries. Eleven computer phantoms were generated using cross-sectional area data from quantitative angiography of stenotic coronary arteries. Three methods of data acquisition were simulated: conventional manual pull-back; motorized pull-back; and manual pull-back with measured displacement. Effects of pull-back velocity and cardiac gating on cross-sectional area profiles and volumes were studied. We rated the methods, measured ~ motorized >> manual. Cardiac gating eliminated errors introduced by vessel deformation within a cardiac cycle. With cardiac gating, pull-backs with mean velocities up to 1.2 mm/sec allowed reconstruction of cross-sectional area profiles within 5% RMS error. With faster pull-backs, cardiac gating resulted in sparse spatial samp ling and significant errors in cross-sectional area profiles. The accuracy of both motorized and measured required equal displacements of the catheter proximal and distal ends. This assumption was validated with in-vitro experiments where x-ray fluoroscopy was used to measure the displacement of the imaging tip. Excellent correlation was found between the two displacements (r = 0.99). Finally, slow pull-backs were performed by 3 operators, and pull-back velocities were measured. It was found that mean pull-back velocities as low as 0.8 mm/sec were achievable. In the second part of the study, we developed a real-time, ICUS pull-back data acquisition scheme to acquire calibrated, cardiac-gated 3D image data sets. A semi-automated border detection scheme was implemented using dynamic programming. To validate the ICUS methodology, multiple pull-backs were performed in phantoms. ICUS volumes were very reproducible (~3% standard deviation) and were close to independently obtained volume measurements obtained from water weight (mean error ~5%). The ICUS volumes also correlated with angiographic analysis which is the current gold standard in coronary imaging (mean error ~1.6%). Clinical applicability was assessed by performing 10 cardiac gated pull-backs in 5 patients before and after directional coronary atherectomy (DCA). Lumen and plaque volumes over the length of the DCA cutter showed that lumen volume improvement occurred due to plaque removal (45%) and vessel expansion (55%). Angiographic measurements of lumen volumes compared favorably. We conclude that volumetric ICUS provides accurate and reproducible estimates and, unlike angiography, provides a direct in-vivo technique for quantifying atherosclerotic plaque volumes. The technique will have direct clinical applicability in regression and restenosis trails."],"dc:format":["application/pdf","p.169","4.18 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1057677172"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Biomedical","Volumetric intracoronary ultrasound."],"dc:title":["Volumetric intracoronary ultrasound"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:13Z"}