{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1057693461"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1057693461","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"An implantable transducer for two-degree-of-freedom joint angle sensing","abstract":"An implantable joint angle transducer (IJAT) was developed for chronic use with upper extremity functional neuromuscular stimulation (FNS) neuroprostheses. The IJAT uses a permanent magnet surgically implanted in one bone, and an array of Hall effect sensors surgically implanted in the opposing bone. As the joint is moved, the sensors detect the relative position and orientation changes of the magnet, producing voltages related to the movement. A mathematical transformation is used to convert the sensor voltages into measures of the joint angle. Titanium encapsulation protects the magnet, sensors, and support electronics, and secures the packages in the bone. The IJAT provides consistent, reliable, high quality signals that reflect joint movement from mid-sized two-degree-of-freedom joints. Mathematical modeling techniques were developed for predicting the transfer characteristics of an IJAT when the magnet and sensor array are surgically placed into joints having different geometric configurations, and for calibrating and characterizing operation of the IJAT after implantation. IJATs were implanted using a chronic in-vivo dog model to demonstrate the feasibility of implantation and periodic measurement techniques, and to validate use of the modeling techniques prediction of function and calibration. The flexion resolution r anged from 0.4° to 3.0° , the maximum deviation from a linear response was 9° , and over joints ranges up to 108° . The resolution and linearity depend on several transducer and joint geometry parameters, and can be predicted pre-implantation and calibrated post-implantation using the modeling techniques. The IJAT is suitable for use as either a command control or feedback sensor.","abstract_html":"An implantable joint angle transducer (IJAT) was developed for chronic use with upper extremity functional neuromuscular stimulation (FNS) neuroprostheses. The IJAT uses a permanent magnet surgically implanted in one bone, and an array of Hall effect sensors surgically implanted in the opposing bone. As the joint is moved, the sensors detect the relative position and orientation changes of the magnet, producing voltages related to the movement. A mathematical transformation is used to convert the sensor voltages into measures of the joint angle. Titanium encapsulation protects the magnet, sensors, and support electronics, and secures the packages in the bone. The IJAT provides consistent, reliable, high quality signals that reflect joint movement from mid-sized two-degree-of-freedom joints. Mathematical modeling techniques were developed for predicting the transfer characteristics of an IJAT when the magnet and sensor array are surgically placed into joints having different geometric configurations, and for calibrating and characterizing operation of the IJAT after implantation. IJATs were implanted using a chronic in-vivo dog model to demonstrate the feasibility of implantation and periodic measurement techniques, and to validate use of the modeling techniques prediction of function and calibration. The flexion resolution r anged from 0.4° to 3.0° , the maximum deviation from a linear response was 9° , and over joints ranges up to 108° . The resolution and linearity depend on several transducer and joint geometry parameters, and can be predicted pre-implantation and calibrated post-implantation using the modeling techniques. The IJAT is suitable for use as either a command control or feedback sensor.","abstract_has_math":false,"creators":["Johnson, Mark William"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Peckham, P."],"committee_chairs":[],"committee_members":[],"year":1994,"date_issued":"1994","date_published":"1994","updated_at":"2026-11-27T04:14:13Z","subjects":["implantable transducer angle sensing"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1057693461","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1057693461","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1057693461","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1057693461","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Peckham, P."]},{"key":"dc:creator","label":"Author","values":["Johnson, Mark William"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1994"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["implantable transducer angle sensing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1057693461"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["An implantable joint angle transducer (IJAT) was developed for chronic use with upper extremity functional neuromuscular stimulation (FNS) neuroprostheses. The IJAT uses a permanent magnet surgically implanted in one bone, and an array of Hall effect sensors surgically implanted in the opposing bone. As the joint is moved, the sensors detect the relative position and orientation changes of the magnet, producing voltages related to the movement. A mathematical transformation is used to convert the sensor voltages into measures of the joint angle. Titanium encapsulation protects the magnet, sensors, and support electronics, and secures the packages in the bone. The IJAT provides consistent, reliable, high quality signals that reflect joint movement from mid-sized two-degree-of-freedom joints. Mathematical modeling techniques were developed for predicting the transfer characteristics of an IJAT when the magnet and sensor array are surgically placed into joints having different geometric configurations, and for calibrating and characterizing operation of the IJAT after implantation. IJATs were implanted using a chronic in-vivo dog model to demonstrate the feasibility of implantation and periodic measurement techniques, and to validate use of the modeling techniques prediction of function and calibration. The flexion resolution r anged from 0.4° to 3.0° , the maximum deviation from a linear response was 9° , and over joints ranges up to 108° . The resolution and linearity depend on several transducer and joint geometry parameters, and can be predicted pre-implantation and calibrated post-implantation using the modeling techniques. The IJAT is suitable for use as either a command control or feedback sensor."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.182","5.47 MB"]},{"key":"dc:title","label":"Title","values":["An implantable transducer for two-degree-of-freedom joint angle sensing"]}]}],"canonical_facts":{"dc:contributor.advisor":["Peckham, P."],"dc:creator":["Johnson, Mark William"],"dc:date":["1994"],"dc:description":["An implantable joint angle transducer (IJAT) was developed for chronic use with upper extremity functional neuromuscular stimulation (FNS) neuroprostheses. The IJAT uses a permanent magnet surgically implanted in one bone, and an array of Hall effect sensors surgically implanted in the opposing bone. As the joint is moved, the sensors detect the relative position and orientation changes of the magnet, producing voltages related to the movement. A mathematical transformation is used to convert the sensor voltages into measures of the joint angle. Titanium encapsulation protects the magnet, sensors, and support electronics, and secures the packages in the bone. The IJAT provides consistent, reliable, high quality signals that reflect joint movement from mid-sized two-degree-of-freedom joints. Mathematical modeling techniques were developed for predicting the transfer characteristics of an IJAT when the magnet and sensor array are surgically placed into joints having different geometric configurations, and for calibrating and characterizing operation of the IJAT after implantation. IJATs were implanted using a chronic in-vivo dog model to demonstrate the feasibility of implantation and periodic measurement techniques, and to validate use of the modeling techniques prediction of function and calibration. The flexion resolution r anged from 0.4° to 3.0° , the maximum deviation from a linear response was 9° , and over joints ranges up to 108° . The resolution and linearity depend on several transducer and joint geometry parameters, and can be predicted pre-implantation and calibrated post-implantation using the modeling techniques. The IJAT is suitable for use as either a command control or feedback sensor."],"dc:format":["application/pdf","p.182","5.47 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1057693461"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["implantable transducer angle sensing"],"dc:title":["An implantable transducer for two-degree-of-freedom joint angle sensing"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:13Z"}