{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1057860662"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1057860662","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Perception and filtering of interventional x-ray fluoroscopy image sequences","abstract":"Due to the proliferation of interventional radiology the use of x-ray fluoroscopy is increasing. Examples of treatments include balloon angioplasty, atherectomy and neuroembolizations. X-ray fluoroscopic imaging at high frame rates and low x-ray dose is used to guide catheters, position interventional devices, and give feedback during intervention. We use image perception experiments, mathematical modeling and image processing to determine ways to reduce x-ray dose and optimize visualization. The human visual system (HVS) temporally filters image sequences, and effectively improves the signal-to-noise ratio (SNR) of an image sequence. It is important to include this phenomenon in the analysis of fluoroscopy. Paired-comparison, min-contrast, and forced-choice perception experiments are used to compare pulsed fluoroscopy at reduced frame rates with conventional continuous fluoroscopy. Experimentally we find average dose savings of 22%, 38%, and 49%, for pulsed at 15, 10 and 7.5 acq/sec, respectively. Dose savings depend on object size, with less savings for smaller objects. Theoretically we extend the framework on an ideal observer with three models of the spatio-temporal response of the HVS: (M1) separable, (M2) non-separable, and (M3) non-separable with internal noise. With no free parameters, M1 predicts the average dose savings within a 3% difference, but does not describe the effect of object size. M2 and M3 explain the influence of size, and M3, with a single free parameter, fits the measurements best. In similar experiments with single frames, we find that processing in the HVS effectively reduces noise variance by a factor of 3, corresponding to an effective averaging time of 100 msec. We suggest several variance reduction techniques to create a single last-image-hold frame having perception equal to the fluoroscopy sequence. Simply reducing the x-ray dose decreases the SNR to unacceptable low levels. We describe an image processing technique to enhance fluoroscopy sequences. The method consists of object detection, followed by spatial and recursive, temporal filtering. Based upon the object detection we adjust filter parameters, such as to reduce noise without blurring the objects. A receiver operating characteristic (ROC) curve analysis is used to optimize matched filters for the object detection. Dependent upon the noise level, the method improves SNR from 6-10 dB, with dose savings approaching 95%.","abstract_html":"Due to the proliferation of interventional radiology the use of x-ray fluoroscopy is increasing. Examples of treatments include balloon angioplasty, atherectomy and neuroembolizations. X-ray fluoroscopic imaging at high frame rates and low x-ray dose is used to guide catheters, position interventional devices, and give feedback during intervention. We use image perception experiments, mathematical modeling and image processing to determine ways to reduce x-ray dose and optimize visualization. The human visual system (HVS) temporally filters image sequences, and effectively improves the signal-to-noise ratio (SNR) of an image sequence. It is important to include this phenomenon in the analysis of fluoroscopy. Paired-comparison, min-contrast, and forced-choice perception experiments are used to compare pulsed fluoroscopy at reduced frame rates with conventional continuous fluoroscopy. Experimentally we find average dose savings of 22%, 38%, and 49%, for pulsed at 15, 10 and 7.5 acq/sec, respectively. Dose savings depend on object size, with less savings for smaller objects. Theoretically we extend the framework on an ideal observer with three models of the spatio-temporal response of the HVS: (M1) separable, (M2) non-separable, and (M3) non-separable with internal noise. With no free parameters, M1 predicts the average dose savings within a 3% difference, but does not describe the effect of object size. M2 and M3 explain the influence of size, and M3, with a single free parameter, fits the measurements best. In similar experiments with single frames, we find that processing in the HVS effectively reduces noise variance by a factor of 3, corresponding to an effective averaging time of 100 msec. We suggest several variance reduction techniques to create a single last-image-hold frame having perception equal to the fluoroscopy sequence. Simply reducing the x-ray dose decreases the SNR to unacceptable low levels. We describe an image processing technique to enhance fluoroscopy sequences. The method consists of object detection, followed by spatial and recursive, temporal filtering. Based upon the object detection we adjust filter parameters, such as to reduce noise without blurring the objects. A receiver operating characteristic (ROC) curve analysis is used to optimize matched filters for the object detection. Dependent upon the noise level, the method improves SNR from 6-10 dB, with dose savings approaching 95%.","abstract_has_math":false,"creators":["Aufrichtig, Richard"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Wilson, David"],"committee_chairs":[],"committee_members":[],"year":1994,"date_issued":"1994","date_published":"1994","updated_at":"2026-11-27T04:14:13Z","subjects":["Perception filtering interventional x-ray fluoroscopy image sequences"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1057860662","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1057860662","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1057860662","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1057860662","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wilson, David"]},{"key":"dc:creator","label":"Author","values":["Aufrichtig, Richard"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1994"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Perception filtering interventional x-ray fluoroscopy image sequences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1057860662"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Due to the proliferation of interventional radiology the use of x-ray fluoroscopy is increasing. Examples of treatments include balloon angioplasty, atherectomy and neuroembolizations. X-ray fluoroscopic imaging at high frame rates and low x-ray dose is used to guide catheters, position interventional devices, and give feedback during intervention. We use image perception experiments, mathematical modeling and image processing to determine ways to reduce x-ray dose and optimize visualization. The human visual system (HVS) temporally filters image sequences, and effectively improves the signal-to-noise ratio (SNR) of an image sequence. It is important to include this phenomenon in the analysis of fluoroscopy. Paired-comparison, min-contrast, and forced-choice perception experiments are used to compare pulsed fluoroscopy at reduced frame rates with conventional continuous fluoroscopy. Experimentally we find average dose savings of 22%, 38%, and 49%, for pulsed at 15, 10 and 7.5 acq/sec, respectively. Dose savings depend on object size, with less savings for smaller objects. Theoretically we extend the framework on an ideal observer with three models of the spatio-temporal response of the HVS: (M1) separable, (M2) non-separable, and (M3) non-separable with internal noise. With no free parameters, M1 predicts the average dose savings within a 3% difference, but does not describe the effect of object size. M2 and M3 explain the influence of size, and M3, with a single free parameter, fits the measurements best. In similar experiments with single frames, we find that processing in the HVS effectively reduces noise variance by a factor of 3, corresponding to an effective averaging time of 100 msec. We suggest several variance reduction techniques to create a single last-image-hold frame having perception equal to the fluoroscopy sequence. Simply reducing the x-ray dose decreases the SNR to unacceptable low levels. We describe an image processing technique to enhance fluoroscopy sequences. The method consists of object detection, followed by spatial and recursive, temporal filtering. Based upon the object detection we adjust filter parameters, such as to reduce noise without blurring the objects. A receiver operating characteristic (ROC) curve analysis is used to optimize matched filters for the object detection. Dependent upon the noise level, the method improves SNR from 6-10 dB, with dose savings approaching 95%."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.180","4.64 MB"]},{"key":"dc:title","label":"Title","values":["Perception and filtering of interventional x-ray fluoroscopy image sequences"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wilson, David"],"dc:creator":["Aufrichtig, Richard"],"dc:date":["1994"],"dc:description":["Due to the proliferation of interventional radiology the use of x-ray fluoroscopy is increasing. Examples of treatments include balloon angioplasty, atherectomy and neuroembolizations. X-ray fluoroscopic imaging at high frame rates and low x-ray dose is used to guide catheters, position interventional devices, and give feedback during intervention. We use image perception experiments, mathematical modeling and image processing to determine ways to reduce x-ray dose and optimize visualization. The human visual system (HVS) temporally filters image sequences, and effectively improves the signal-to-noise ratio (SNR) of an image sequence. It is important to include this phenomenon in the analysis of fluoroscopy. Paired-comparison, min-contrast, and forced-choice perception experiments are used to compare pulsed fluoroscopy at reduced frame rates with conventional continuous fluoroscopy. Experimentally we find average dose savings of 22%, 38%, and 49%, for pulsed at 15, 10 and 7.5 acq/sec, respectively. Dose savings depend on object size, with less savings for smaller objects. Theoretically we extend the framework on an ideal observer with three models of the spatio-temporal response of the HVS: (M1) separable, (M2) non-separable, and (M3) non-separable with internal noise. With no free parameters, M1 predicts the average dose savings within a 3% difference, but does not describe the effect of object size. M2 and M3 explain the influence of size, and M3, with a single free parameter, fits the measurements best. In similar experiments with single frames, we find that processing in the HVS effectively reduces noise variance by a factor of 3, corresponding to an effective averaging time of 100 msec. We suggest several variance reduction techniques to create a single last-image-hold frame having perception equal to the fluoroscopy sequence. Simply reducing the x-ray dose decreases the SNR to unacceptable low levels. We describe an image processing technique to enhance fluoroscopy sequences. The method consists of object detection, followed by spatial and recursive, temporal filtering. Based upon the object detection we adjust filter parameters, such as to reduce noise without blurring the objects. A receiver operating characteristic (ROC) curve analysis is used to optimize matched filters for the object detection. Dependent upon the noise level, the method improves SNR from 6-10 dB, with dose savings approaching 95%."],"dc:format":["application/pdf","p.180","4.64 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1057860662"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Perception filtering interventional x-ray fluoroscopy image sequences"],"dc:title":["Perception and filtering of interventional x-ray fluoroscopy image sequences"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:13Z"}