{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1058448071"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1058448071","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"System models of skeletal muscle","abstract":"Hill-based models are popular and are used widely to describe muscle behavior in non-isometric contractions. However, the models were found to lack generality during simultaneous modulation of stimulation and length and did not adequately describe the post yielding behavior in response to stretch. In this research, we improved the generality of the Hill-type model to enable applications in motor neuroprostheses with either fixed parameters or parameter adaptation. An uncoupled muscle-joint model with the simplest Hill-type structure showed great potential for applications in which continuous parameter adaptation is possible. The model was evaluated for its ability to fit the joint moments produced by the stimulated cat soleus muscle during simultaneous modulation of stimulation and joint angle inputs. The model fit the experimental data well for a given operating point, defined by a mean angle and a range of perturbation amplitudes and velocities. Changing in the testing conditions resulted in large errors, but with continuous parameter adaptation, the errors reduced quickly since the model parameter values converged quickly to the best parameter values of the new condition. For applications requiring fixed parameter values, a coupled muscle-tendon model incorporating the Hill-ty pe structure and length dependent coupling between activation and velocity showed generality during random perturbations and iso-velocity movements. The model correctly described the response to iso-velocity movements, including short range stiffness, post field force drop, and steady force change following the force drop. The length-tension estimate was influenced by the effective stimulus frequency, limiting the model to constant frequency application. We also evaluated the abilities of the coupled and an uncoupled Hill-type muscle-tendon models to predict the short range stiffness properties during alternating and sequential ramp movements. The short range stiffness properties are predicted well by both models. Furthermore, the results suggest that the short range stiffness properties are dominated by the active damping property and its recovery is modulated by the coupling structure","abstract_html":"Hill-based models are popular and are used widely to describe muscle behavior in non-isometric contractions. However, the models were found to lack generality during simultaneous modulation of stimulation and length and did not adequately describe the post yielding behavior in response to stretch. In this research, we improved the generality of the Hill-type model to enable applications in motor neuroprostheses with either fixed parameters or parameter adaptation. An uncoupled muscle-joint model with the simplest Hill-type structure showed great potential for applications in which continuous parameter adaptation is possible. The model was evaluated for its ability to fit the joint moments produced by the stimulated cat soleus muscle during simultaneous modulation of stimulation and joint angle inputs. The model fit the experimental data well for a given operating point, defined by a mean angle and a range of perturbation amplitudes and velocities. Changing in the testing conditions resulted in large errors, but with continuous parameter adaptation, the errors reduced quickly since the model parameter values converged quickly to the best parameter values of the new condition. For applications requiring fixed parameter values, a coupled muscle-tendon model incorporating the Hill-ty pe structure and length dependent coupling between activation and velocity showed generality during random perturbations and iso-velocity movements. The model correctly described the response to iso-velocity movements, including short range stiffness, post field force drop, and steady force change following the force drop. The length-tension estimate was influenced by the effective stimulus frequency, limiting the model to constant frequency application. We also evaluated the abilities of the coupled and an uncoupled Hill-type muscle-tendon models to predict the short range stiffness properties during alternating and sequential ramp movements. The short range stiffness properties are predicted well by both models. Furthermore, the results suggest that the short range stiffness properties are dominated by the active damping property and its recovery is modulated by the coupling structure","abstract_has_math":false,"creators":["Shue, Guay-Haur"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Crago, Patrick"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1995,"date_issued":"1995","date_published":"1995","updated_at":"2026-11-26T03:16:32Z","subjects":["Biophysics, Medical","Skeletal muscle"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1058448071","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1058448071","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1058448071","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1058448071","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Crago, Patrick"]},{"key":"dc:creator","label":"Author","values":["Shue, Guay-Haur"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1995"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biophysics, Medical","Skeletal muscle"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1058448071"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Hill-based models are popular and are used widely to describe muscle behavior in non-isometric contractions. However, the models were found to lack generality during simultaneous modulation of stimulation and length and did not adequately describe the post yielding behavior in response to stretch. In this research, we improved the generality of the Hill-type model to enable applications in motor neuroprostheses with either fixed parameters or parameter adaptation. An uncoupled muscle-joint model with the simplest Hill-type structure showed great potential for applications in which continuous parameter adaptation is possible. The model was evaluated for its ability to fit the joint moments produced by the stimulated cat soleus muscle during simultaneous modulation of stimulation and joint angle inputs. The model fit the experimental data well for a given operating point, defined by a mean angle and a range of perturbation amplitudes and velocities. Changing in the testing conditions resulted in large errors, but with continuous parameter adaptation, the errors reduced quickly since the model parameter values converged quickly to the best parameter values of the new condition. For applications requiring fixed parameter values, a coupled muscle-tendon model incorporating the Hill-ty pe structure and length dependent coupling between activation and velocity showed generality during random perturbations and iso-velocity movements. The model correctly described the response to iso-velocity movements, including short range stiffness, post field force drop, and steady force change following the force drop. The length-tension estimate was influenced by the effective stimulus frequency, limiting the model to constant frequency application. We also evaluated the abilities of the coupled and an uncoupled Hill-type muscle-tendon models to predict the short range stiffness properties during alternating and sequential ramp movements. The short range stiffness properties are predicted well by both models. Furthermore, the results suggest that the short range stiffness properties are dominated by the active damping property and its recovery is modulated by the coupling structure"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.123","3.89 MB"]},{"key":"dc:title","label":"Title","values":["System models of skeletal muscle"]}]}],"canonical_facts":{"dc:contributor":["Crago, Patrick"],"dc:creator":["Shue, Guay-Haur"],"dc:date":["1995"],"dc:description":["Hill-based models are popular and are used widely to describe muscle behavior in non-isometric contractions. However, the models were found to lack generality during simultaneous modulation of stimulation and length and did not adequately describe the post yielding behavior in response to stretch. In this research, we improved the generality of the Hill-type model to enable applications in motor neuroprostheses with either fixed parameters or parameter adaptation. An uncoupled muscle-joint model with the simplest Hill-type structure showed great potential for applications in which continuous parameter adaptation is possible. The model was evaluated for its ability to fit the joint moments produced by the stimulated cat soleus muscle during simultaneous modulation of stimulation and joint angle inputs. The model fit the experimental data well for a given operating point, defined by a mean angle and a range of perturbation amplitudes and velocities. Changing in the testing conditions resulted in large errors, but with continuous parameter adaptation, the errors reduced quickly since the model parameter values converged quickly to the best parameter values of the new condition. For applications requiring fixed parameter values, a coupled muscle-tendon model incorporating the Hill-ty pe structure and length dependent coupling between activation and velocity showed generality during random perturbations and iso-velocity movements. The model correctly described the response to iso-velocity movements, including short range stiffness, post field force drop, and steady force change following the force drop. The length-tension estimate was influenced by the effective stimulus frequency, limiting the model to constant frequency application. We also evaluated the abilities of the coupled and an uncoupled Hill-type muscle-tendon models to predict the short range stiffness properties during alternating and sequential ramp movements. The short range stiffness properties are predicted well by both models. Furthermore, the results suggest that the short range stiffness properties are dominated by the active damping property and its recovery is modulated by the coupling structure"],"dc:format":["application/pdf","p.123","3.89 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1058448071"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biophysics, Medical","Skeletal muscle"],"dc:title":["System models of skeletal muscle"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:16:32Z"}