{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1060797619"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1060797619","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Fatigue performance of AASHTO and Ontario design for non-composite reinforced concrete bridge decks","abstract":"Tests were conducted under a concentrated static, stationary pulsating and moving constant wheel-load on 1/3-scale (P-Series) and 1/6.6-scale (B-Series) physical models of concrete bridge decks of a simply supported non-composite 50-ft long bridge with an 8.5-in. thick concrete deck supported on four steel girders spaced at 7 and 10 ft. Three deck designs are studied: (a) AASHTO \"orthotropic\" steel reinforcement, (b) Ontario \"isotropic\" steel reinforcement, and (c) \"isotropic\" minimum steel reinforcement. The presence of membrane compressive forces (arching action) in the deck enhances its static ultimate strength. Static ultimate strength values for the decks, P u, up to about three times the Johansen load are measured. The predicted critical deflections at instability of a 2-D 3-hinge compressive strut model (snap-through mechanism) restrained at the pinned supports by a horizontal elastic spring, and subjected at the crown to a concentrated vertical load correlate well with the measured ultimate deck deflections. The type of applied fatigue loading has a profound influence on the fatigue behavior of the decks. Under a moving constant wheel-load, the initial two-way deck slab action changes to a one-way slab action as failure is approached. The bridge decks subjected to a stationary pulsating load exhibited a flexural radial cracking, while those under a moving constant wheel-load exhibited a flexural grid-like pattern similar to the grid of the bottom steel layer. For a given applied fatigue load level, the decks subjected to a stationary pulsating loading regime exhibited higher fatigue life than those subjected to a moving load. Based on an exponential curve fit of the fatigue data in this study (log P/P u vs. logN cf or logN pf), while the 2.5 × 10<sup>6</sup> load cycle fatigue strength of the deck models under a stationary pulsating load ranges between 0.47 and 0.54 P u (safety factor 5 ÷ 12), at 2.5 × 10<sup>6</sup> wheel-load passages under a moving wheel-load is estimated to be at 0.21 to 0.28 P u (safety factor 2 ÷ 4). The fatigue strength of the bridge decks under a moving constant wheel-load is in the same range as the cracking load level while the fatigue strength under a stationary pulsating load is similar to the yielding load level for the steel reinforcement. (Abstract shortened by UMI.)","abstract_html":"Tests were conducted under a concentrated static, stationary pulsating and moving constant wheel-load on 1/3-scale (P-Series) and 1/6.6-scale (B-Series) physical models of concrete bridge decks of a simply supported non-composite 50-ft long bridge with an 8.5-in. thick concrete deck supported on four steel girders spaced at 7 and 10 ft. Three deck designs are studied: (a) AASHTO &quot;orthotropic&quot; steel reinforcement, (b) Ontario &quot;isotropic&quot; steel reinforcement, and (c) &quot;isotropic&quot; minimum steel reinforcement. The presence of membrane compressive forces (arching action) in the deck enhances its static ultimate strength. Static ultimate strength values for the decks, P u, up to about three times the Johansen load are measured. The predicted critical deflections at instability of a 2-D 3-hinge compressive strut model (snap-through mechanism) restrained at the pinned supports by a horizontal elastic spring, and subjected at the crown to a concentrated vertical load correlate well with the measured ultimate deck deflections. The type of applied fatigue loading has a profound influence on the fatigue behavior of the decks. Under a moving constant wheel-load, the initial two-way deck slab action changes to a one-way slab action as failure is approached. The bridge decks subjected to a stationary pulsating load exhibited a flexural radial cracking, while those under a moving constant wheel-load exhibited a flexural grid-like pattern similar to the grid of the bottom steel layer. For a given applied fatigue load level, the decks subjected to a stationary pulsating loading regime exhibited higher fatigue life than those subjected to a moving load. Based on an exponential curve fit of the fatigue data in this study (log P/P u vs. logN cf or logN pf), while the 2.5 × 10&lt;sup&gt;6&lt;/sup&gt; load cycle fatigue strength of the deck models under a stationary pulsating load ranges between 0.47 and 0.54 P u (safety factor 5 ÷ 12), at 2.5 × 10&lt;sup&gt;6&lt;/sup&gt; wheel-load passages under a moving wheel-load is estimated to be at 0.21 to 0.28 P u (safety factor 2 ÷ 4). The fatigue strength of the bridge decks under a moving constant wheel-load is in the same range as the cracking load level while the fatigue strength under a stationary pulsating load is similar to the yielding load level for the steel reinforcement. (Abstract shortened by UMI.)","abstract_has_math":false,"creators":["Petrou, Michael Frixos"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":["Perdikaris, Philip"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1993,"date_issued":"1993","date_published":"1993","updated_at":"2026-11-26T03:16:47Z","subjects":["Engineering, Civil","Concrete bridge decks","Fatigue performance"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1060797619","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1060797619","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1060797619","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1060797619","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Perdikaris, Philip"]},{"key":"dc:creator","label":"Author","values":["Petrou, Michael Frixos"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1993"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Civil","Concrete bridge decks","Fatigue performance"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1060797619"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Tests were conducted under a concentrated static, stationary pulsating and moving constant wheel-load on 1/3-scale (P-Series) and 1/6.6-scale (B-Series) physical models of concrete bridge decks of a simply supported non-composite 50-ft long bridge with an 8.5-in. thick concrete deck supported on four steel girders spaced at 7 and 10 ft. Three deck designs are studied: (a) AASHTO \"orthotropic\" steel reinforcement, (b) Ontario \"isotropic\" steel reinforcement, and (c) \"isotropic\" minimum steel reinforcement. The presence of membrane compressive forces (arching action) in the deck enhances its static ultimate strength. Static ultimate strength values for the decks, P u, up to about three times the Johansen load are measured. The predicted critical deflections at instability of a 2-D 3-hinge compressive strut model (snap-through mechanism) restrained at the pinned supports by a horizontal elastic spring, and subjected at the crown to a concentrated vertical load correlate well with the measured ultimate deck deflections. The type of applied fatigue loading has a profound influence on the fatigue behavior of the decks. Under a moving constant wheel-load, the initial two-way deck slab action changes to a one-way slab action as failure is approached. The bridge decks subjected to a stationary pulsating load exhibited a flexural radial cracking, while those under a moving constant wheel-load exhibited a flexural grid-like pattern similar to the grid of the bottom steel layer. For a given applied fatigue load level, the decks subjected to a stationary pulsating loading regime exhibited higher fatigue life than those subjected to a moving load. Based on an exponential curve fit of the fatigue data in this study (log P/P u vs. logN cf or logN pf), while the 2.5 × 10<sup>6</sup> load cycle fatigue strength of the deck models under a stationary pulsating load ranges between 0.47 and 0.54 P u (safety factor 5 ÷ 12), at 2.5 × 10<sup>6</sup> wheel-load passages under a moving wheel-load is estimated to be at 0.21 to 0.28 P u (safety factor 2 ÷ 4). The fatigue strength of the bridge decks under a moving constant wheel-load is in the same range as the cracking load level while the fatigue strength under a stationary pulsating load is similar to the yielding load level for the steel reinforcement. (Abstract shortened by UMI.)"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.299","8.07 MB"]},{"key":"dc:title","label":"Title","values":["Fatigue performance of AASHTO and Ontario design for non-composite reinforced concrete bridge decks"]}]}],"canonical_facts":{"dc:contributor":["Perdikaris, Philip"],"dc:creator":["Petrou, Michael Frixos"],"dc:date":["1993"],"dc:description":["Tests were conducted under a concentrated static, stationary pulsating and moving constant wheel-load on 1/3-scale (P-Series) and 1/6.6-scale (B-Series) physical models of concrete bridge decks of a simply supported non-composite 50-ft long bridge with an 8.5-in. thick concrete deck supported on four steel girders spaced at 7 and 10 ft. Three deck designs are studied: (a) AASHTO \"orthotropic\" steel reinforcement, (b) Ontario \"isotropic\" steel reinforcement, and (c) \"isotropic\" minimum steel reinforcement. The presence of membrane compressive forces (arching action) in the deck enhances its static ultimate strength. Static ultimate strength values for the decks, P u, up to about three times the Johansen load are measured. The predicted critical deflections at instability of a 2-D 3-hinge compressive strut model (snap-through mechanism) restrained at the pinned supports by a horizontal elastic spring, and subjected at the crown to a concentrated vertical load correlate well with the measured ultimate deck deflections. The type of applied fatigue loading has a profound influence on the fatigue behavior of the decks. Under a moving constant wheel-load, the initial two-way deck slab action changes to a one-way slab action as failure is approached. The bridge decks subjected to a stationary pulsating load exhibited a flexural radial cracking, while those under a moving constant wheel-load exhibited a flexural grid-like pattern similar to the grid of the bottom steel layer. For a given applied fatigue load level, the decks subjected to a stationary pulsating loading regime exhibited higher fatigue life than those subjected to a moving load. Based on an exponential curve fit of the fatigue data in this study (log P/P u vs. logN cf or logN pf), while the 2.5 × 10<sup>6</sup> load cycle fatigue strength of the deck models under a stationary pulsating load ranges between 0.47 and 0.54 P u (safety factor 5 ÷ 12), at 2.5 × 10<sup>6</sup> wheel-load passages under a moving wheel-load is estimated to be at 0.21 to 0.28 P u (safety factor 2 ÷ 4). The fatigue strength of the bridge decks under a moving constant wheel-load is in the same range as the cracking load level while the fatigue strength under a stationary pulsating load is similar to the yielding load level for the steel reinforcement. (Abstract shortened by UMI.)"],"dc:format":["application/pdf","p.299","8.07 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1060797619"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Civil","Concrete bridge decks","Fatigue performance"],"dc:title":["Fatigue performance of AASHTO and Ontario design for non-composite reinforced concrete bridge decks"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:16:47Z"}