{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1062595642"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1062595642","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Dynamic model of the hand with application in functional neuromuscular stimulation","abstract":"A dynamic model of hand was generated and used to study potential hand functions on hand positioning and grasp force and the outcome of surgeries such as tendon transfers and joint fusions, in situations typical of those encountered in FNS. In the model, the hand is being treated as a multi-body system including rigid segments (phalanges and palm) connected by joints. Each joint is subjected to muscle moments, produced by a muscle model, passive joint moment and external force moments. The external forces are the result of interaction forces between the hand segments and a grasped fixed or movable object. In particular, the model was used to study the non-prehensile tip and palmar pinch movements, and to simulate prehensile lateral and palmar grasp functions of the hand. A quasi-linear viscoelastic model was found to described the joint passive moment. Model simulations showed that, in the absence of external forces, tip pinch posture is not obtained using only the extrinsic muscles. The currently used tendon transfer methods were found useful in normal hands but not significantly effective in quadriplegic hands. It was also found that activation of multiple thumb muscles (ADP, APB and FPL) without surgical alterations can provide functional lateral pinch with about 70% more grip force than the currently used method with joint fusion. A grasp protocol was introduced and shown successful in palmar grasp and hold of movable cylindrical objects using only extrinsic muscles","abstract_html":"A dynamic model of hand was generated and used to study potential hand functions on hand positioning and grasp force and the outcome of surgeries such as tendon transfers and joint fusions, in situations typical of those encountered in FNS. In the model, the hand is being treated as a multi-body system including rigid segments (phalanges and palm) connected by joints. Each joint is subjected to muscle moments, produced by a muscle model, passive joint moment and external force moments. The external forces are the result of interaction forces between the hand segments and a grasped fixed or movable object. In particular, the model was used to study the non-prehensile tip and palmar pinch movements, and to simulate prehensile lateral and palmar grasp functions of the hand. A quasi-linear viscoelastic model was found to described the joint passive moment. Model simulations showed that, in the absence of external forces, tip pinch posture is not obtained using only the extrinsic muscles. The currently used tendon transfer methods were found useful in normal hands but not significantly effective in quadriplegic hands. It was also found that activation of multiple thumb muscles (ADP, APB and FPL) without surgical alterations can provide functional lateral pinch with about 70% more grip force than the currently used method with joint fusion. A grasp protocol was introduced and shown successful in palmar grasp and hold of movable cylindrical objects using only extrinsic muscles","abstract_has_math":false,"creators":["Esteki, Ali"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Mansour, Joseph"],"committee_chairs":[],"committee_members":[],"year":1995,"date_issued":"1995","date_published":"1995","updated_at":"2026-11-27T04:14:19Z","subjects":["Engineering, Biomedical","Hand functions","Neuromuscular stimulation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1062595642","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1062595642","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1062595642","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1062595642","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mansour, Joseph"]},{"key":"dc:creator","label":"Author","values":["Esteki, Ali"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1995"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Biomedical","Hand functions","Neuromuscular stimulation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1062595642"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A dynamic model of hand was generated and used to study potential hand functions on hand positioning and grasp force and the outcome of surgeries such as tendon transfers and joint fusions, in situations typical of those encountered in FNS. In the model, the hand is being treated as a multi-body system including rigid segments (phalanges and palm) connected by joints. Each joint is subjected to muscle moments, produced by a muscle model, passive joint moment and external force moments. The external forces are the result of interaction forces between the hand segments and a grasped fixed or movable object. In particular, the model was used to study the non-prehensile tip and palmar pinch movements, and to simulate prehensile lateral and palmar grasp functions of the hand. A quasi-linear viscoelastic model was found to described the joint passive moment. Model simulations showed that, in the absence of external forces, tip pinch posture is not obtained using only the extrinsic muscles. The currently used tendon transfer methods were found useful in normal hands but not significantly effective in quadriplegic hands. It was also found that activation of multiple thumb muscles (ADP, APB and FPL) without surgical alterations can provide functional lateral pinch with about 70% more grip force than the currently used method with joint fusion. A grasp protocol was introduced and shown successful in palmar grasp and hold of movable cylindrical objects using only extrinsic muscles"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.206","5.09 MB"]},{"key":"dc:title","label":"Title","values":["Dynamic model of the hand with application in functional neuromuscular stimulation"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mansour, Joseph"],"dc:creator":["Esteki, Ali"],"dc:date":["1995"],"dc:description":["A dynamic model of hand was generated and used to study potential hand functions on hand positioning and grasp force and the outcome of surgeries such as tendon transfers and joint fusions, in situations typical of those encountered in FNS. In the model, the hand is being treated as a multi-body system including rigid segments (phalanges and palm) connected by joints. Each joint is subjected to muscle moments, produced by a muscle model, passive joint moment and external force moments. The external forces are the result of interaction forces between the hand segments and a grasped fixed or movable object. In particular, the model was used to study the non-prehensile tip and palmar pinch movements, and to simulate prehensile lateral and palmar grasp functions of the hand. A quasi-linear viscoelastic model was found to described the joint passive moment. Model simulations showed that, in the absence of external forces, tip pinch posture is not obtained using only the extrinsic muscles. The currently used tendon transfer methods were found useful in normal hands but not significantly effective in quadriplegic hands. It was also found that activation of multiple thumb muscles (ADP, APB and FPL) without surgical alterations can provide functional lateral pinch with about 70% more grip force than the currently used method with joint fusion. A grasp protocol was introduced and shown successful in palmar grasp and hold of movable cylindrical objects using only extrinsic muscles"],"dc:format":["application/pdf","p.206","5.09 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1062595642"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Biomedical","Hand functions","Neuromuscular stimulation"],"dc:title":["Dynamic model of the hand with application in functional neuromuscular stimulation"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:19Z"}