{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1081513453"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1081513453","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Synergistic Neural Network Control of FES Elbow Extension After Spinal Cord Injury Using EMG","abstract":"Individuals with a C5/C6 spinal cord injury (SCI) have paralyzed elbow extensors, yet retain weak to strong voluntary control of elbow flexion and some shoulder movements. They lack elbow extension, which is critical during activities of daily living. This research focuses on development of a synergistic controller employing remaining voluntary elbow flexor and shoulder electromyography (EMG) to control elbow extension with functional electrical stimulation (FES). We hypothesized that the remaining voluntarily controlled upper extremity muscles of a C5/C6 SCI subject could be used as inputs to train a neural network controller to output stimulation to the paralyzed triceps. A biomechanical model of the shoulder and arm was used to estimate the triceps stimulation levels required for a particular subject to achieve a variety of endpoint force vectors of varying location, direction, and magnitude. Surface EMG was collected from SCI subjects while they generated these isometric force vectors using the predicted triceps stimulation levels. The EMG’s were used as inputs to train and test an artificial neural network to output triceps stimulation level. A separate synergistic network controller was successfully trained for each subject. The best set of muscle inputs were selected for each subject such that the trained network yielded low error and generalized, the required number of EMG inputs was minimized, the controller effectively learned the relationships between endpoint force direction and required triceps stimulation, and the input (EMG) – output (triceps stimulation) controller space map was smooth with distinct volumes producing stimulation. The synergistic controller was functionally implemented in SCI subjects and compared to constant level and no triceps stimulation during maximum isometric forces, discrete force tracking, and functional overhead reach. The synergistic controller effectively modulated triceps FES and provided the largest range of isometric forces at all endpoint locations and directions compared to constant or no triceps stimulation. Synergistic control allowed subjects to track goal isometric force vectors with no decrease in performance compared to constant stimulation while requiring less stimulation. Additionally, the synergistic controller allowed completion of a functional overhead reach task not possible without active elbow extension.","abstract_html":"Individuals with a C5/C6 spinal cord injury (SCI) have paralyzed elbow extensors, yet retain weak to strong voluntary control of elbow flexion and some shoulder movements. They lack elbow extension, which is critical during activities of daily living. This research focuses on development of a synergistic controller employing remaining voluntary elbow flexor and shoulder electromyography (EMG) to control elbow extension with functional electrical stimulation (FES). We hypothesized that the remaining voluntarily controlled upper extremity muscles of a C5/C6 SCI subject could be used as inputs to train a neural network controller to output stimulation to the paralyzed triceps. A biomechanical model of the shoulder and arm was used to estimate the triceps stimulation levels required for a particular subject to achieve a variety of endpoint force vectors of varying location, direction, and magnitude. Surface EMG was collected from SCI subjects while they generated these isometric force vectors using the predicted triceps stimulation levels. The EMG’s were used as inputs to train and test an artificial neural network to output triceps stimulation level. A separate synergistic network controller was successfully trained for each subject. The best set of muscle inputs were selected for each subject such that the trained network yielded low error and generalized, the required number of EMG inputs was minimized, the controller effectively learned the relationships between endpoint force direction and required triceps stimulation, and the input (EMG) – output (triceps stimulation) controller space map was smooth with distinct volumes producing stimulation. The synergistic controller was functionally implemented in SCI subjects and compared to constant level and no triceps stimulation during maximum isometric forces, discrete force tracking, and functional overhead reach. The synergistic controller effectively modulated triceps FES and provided the largest range of isometric forces at all endpoint locations and directions compared to constant or no triceps stimulation. Synergistic control allowed subjects to track goal isometric force vectors with no decrease in performance compared to constant stimulation while requiring less stimulation. Additionally, the synergistic controller allowed completion of a functional overhead reach task not possible without active elbow extension.","abstract_has_math":false,"creators":["Giuffrida, Joseph P."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Crago, Patrick"],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-04-09","date_published":"2004-04-09","updated_at":"2026-11-27T04:14:19Z","subjects":["neuroprosthetics","spinal cord injury","elbow extension","electromyography","neural networks","functional electrical stimulation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1081513453","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1081513453","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1081513453","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1081513453","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Crago, Patrick"]},{"key":"dc:creator","label":"Author","values":["Giuffrida, Joseph P."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2004-04-09"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["neuroprosthetics","spinal cord injury","elbow extension","electromyography","neural networks","functional electrical stimulation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1081513453"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Individuals with a C5/C6 spinal cord injury (SCI) have paralyzed elbow extensors, yet retain weak to strong voluntary control of elbow flexion and some shoulder movements. They lack elbow extension, which is critical during activities of daily living. This research focuses on development of a synergistic controller employing remaining voluntary elbow flexor and shoulder electromyography (EMG) to control elbow extension with functional electrical stimulation (FES). We hypothesized that the remaining voluntarily controlled upper extremity muscles of a C5/C6 SCI subject could be used as inputs to train a neural network controller to output stimulation to the paralyzed triceps. A biomechanical model of the shoulder and arm was used to estimate the triceps stimulation levels required for a particular subject to achieve a variety of endpoint force vectors of varying location, direction, and magnitude. Surface EMG was collected from SCI subjects while they generated these isometric force vectors using the predicted triceps stimulation levels. The EMG’s were used as inputs to train and test an artificial neural network to output triceps stimulation level. A separate synergistic network controller was successfully trained for each subject. The best set of muscle inputs were selected for each subject such that the trained network yielded low error and generalized, the required number of EMG inputs was minimized, the controller effectively learned the relationships between endpoint force direction and required triceps stimulation, and the input (EMG) – output (triceps stimulation) controller space map was smooth with distinct volumes producing stimulation. The synergistic controller was functionally implemented in SCI subjects and compared to constant level and no triceps stimulation during maximum isometric forces, discrete force tracking, and functional overhead reach. The synergistic controller effectively modulated triceps FES and provided the largest range of isometric forces at all endpoint locations and directions compared to constant or no triceps stimulation. Synergistic control allowed subjects to track goal isometric force vectors with no decrease in performance compared to constant stimulation while requiring less stimulation. Additionally, the synergistic controller allowed completion of a functional overhead reach task not possible without active elbow extension."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","7.18 MB"]},{"key":"dc:title","label":"Title","values":["Synergistic Neural Network Control of FES Elbow Extension After Spinal Cord Injury Using EMG"]}]}],"canonical_facts":{"dc:contributor.advisor":["Crago, Patrick"],"dc:creator":["Giuffrida, Joseph P."],"dc:date":["2004-04-09"],"dc:description":["Individuals with a C5/C6 spinal cord injury (SCI) have paralyzed elbow extensors, yet retain weak to strong voluntary control of elbow flexion and some shoulder movements. They lack elbow extension, which is critical during activities of daily living. This research focuses on development of a synergistic controller employing remaining voluntary elbow flexor and shoulder electromyography (EMG) to control elbow extension with functional electrical stimulation (FES). We hypothesized that the remaining voluntarily controlled upper extremity muscles of a C5/C6 SCI subject could be used as inputs to train a neural network controller to output stimulation to the paralyzed triceps. A biomechanical model of the shoulder and arm was used to estimate the triceps stimulation levels required for a particular subject to achieve a variety of endpoint force vectors of varying location, direction, and magnitude. Surface EMG was collected from SCI subjects while they generated these isometric force vectors using the predicted triceps stimulation levels. The EMG’s were used as inputs to train and test an artificial neural network to output triceps stimulation level. A separate synergistic network controller was successfully trained for each subject. The best set of muscle inputs were selected for each subject such that the trained network yielded low error and generalized, the required number of EMG inputs was minimized, the controller effectively learned the relationships between endpoint force direction and required triceps stimulation, and the input (EMG) – output (triceps stimulation) controller space map was smooth with distinct volumes producing stimulation. The synergistic controller was functionally implemented in SCI subjects and compared to constant level and no triceps stimulation during maximum isometric forces, discrete force tracking, and functional overhead reach. The synergistic controller effectively modulated triceps FES and provided the largest range of isometric forces at all endpoint locations and directions compared to constant or no triceps stimulation. Synergistic control allowed subjects to track goal isometric force vectors with no decrease in performance compared to constant stimulation while requiring less stimulation. Additionally, the synergistic controller allowed completion of a functional overhead reach task not possible without active elbow extension."],"dc:format":["application/pdf","7.18 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1081513453"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["neuroprosthetics","spinal cord injury","elbow extension","electromyography","neural networks","functional electrical stimulation"],"dc:title":["Synergistic Neural Network Control of FES Elbow Extension After Spinal Cord Injury Using EMG"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:19Z"}