{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1081536516"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1081536516","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"SELECTIVE STIMULATION AND RECORDING OF THE CANINE HYPOGLOSSAL NERVE FOR THE TREATMENT OF OBSTRUCTIVE SLEEP APNEA","abstract":"As an alternative to the myriad treatment methods (e.g., tracheostomy) that have been employed to alleviate the characteristic symptoms of obstructive sleep apnea (OSA), electrical stimulation of the hypoglossal (XII) nerve has been shown as a potentially effective therapeutic option. Despite significant improvements in upper airway (UAW) mechanics and reductions in the apnea plus hypopnea index (AHI; measure of OSA severity), inconsistent results (i.e., partial or no effect on AHI) have been observed for non-selective stimulation. In order to account for this unpredictable response to neural stimulation and to also generate a feedback signal to control therapeutic stimulation, a single nerve cuff electrode is presented as means to achieving these objectives. To this end, we first investigated the ability of the multi-contact flat-interface-nerve-electrode (FINE) to stimulate selectively the discrete branches of the beagle XII nerve. Using the recorded neural and muscular responses to electrical pulses delivered through the FINE, a selectivity index (0 ≤ SI ≤ 1) was used to show the degree of selectivity achieved with this electrode: 0.93 ± 0.03 (n = 5) and 0.88 ± 0.03 (n = 4), respectively. This was, in fact, similar to stimulating each individual branch: 0.91 ± 0.02 (n = 4). Second, the feasibility of using the FINE to record selectively the neural activity of the same nerve was studied via (1) a finite element model of a canine XII nerve and (2) comparison with experimental data. The results not only showed that the recording selectivity (SI; ability to distinguish two active sources) was a function of inter-fiber distance but that the minimum inter-fiber distance for this particular nerve electrode can be predicted at physiological signal-to-noise (SNR) levels (e.g., 0.54 mm at 2 dB). Finally, the effects of selective stimulation on the isolated beagle XII nerve showed that the most significant improvements in the UAW flow mechanics (i.e., R <sub>UAW</sub> and P <sub>crit</sub> ) are achieved through whole XII nerve stimulation and co-activation of the GG & HG/SG muscles during expiration and inspiration, respectively. Accordingly, non-selective control may be sufficient to achieve maximum therapeutic outcome.","abstract_html":"As an alternative to the myriad treatment methods (e.g., tracheostomy) that have been employed to alleviate the characteristic symptoms of obstructive sleep apnea (OSA), electrical stimulation of the hypoglossal (XII) nerve has been shown as a potentially effective therapeutic option. Despite significant improvements in upper airway (UAW) mechanics and reductions in the apnea plus hypopnea index (AHI; measure of OSA severity), inconsistent results (i.e., partial or no effect on AHI) have been observed for non-selective stimulation. In order to account for this unpredictable response to neural stimulation and to also generate a feedback signal to control therapeutic stimulation, a single nerve cuff electrode is presented as means to achieving these objectives. To this end, we first investigated the ability of the multi-contact flat-interface-nerve-electrode (FINE) to stimulate selectively the discrete branches of the beagle XII nerve. Using the recorded neural and muscular responses to electrical pulses delivered through the FINE, a selectivity index (0 ≤ SI ≤ 1) was used to show the degree of selectivity achieved with this electrode: 0.93 ± 0.03 (n = 5) and 0.88 ± 0.03 (n = 4), respectively. This was, in fact, similar to stimulating each individual branch: 0.91 ± 0.02 (n = 4). Second, the feasibility of using the FINE to record selectively the neural activity of the same nerve was studied via (1) a finite element model of a canine XII nerve and (2) comparison with experimental data. The results not only showed that the recording selectivity (SI; ability to distinguish two active sources) was a function of inter-fiber distance but that the minimum inter-fiber distance for this particular nerve electrode can be predicted at physiological signal-to-noise (SNR) levels (e.g., 0.54 mm at 2 dB). Finally, the effects of selective stimulation on the isolated beagle XII nerve showed that the most significant improvements in the UAW flow mechanics (i.e., R &lt;sub&gt;UAW&lt;/sub&gt; and P &lt;sub&gt;crit&lt;/sub&gt; ) are achieved through whole XII nerve stimulation and co-activation of the GG &amp; HG/SG muscles during expiration and inspiration, respectively. Accordingly, non-selective control may be sufficient to achieve maximum therapeutic outcome.","abstract_has_math":false,"creators":["Yoo, Paul B."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Durand, Dominique"],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-04-12","date_published":"2004-04-12","updated_at":"2026-11-27T04:14:19Z","subjects":["Engineering, Biomedical","Electrical Stimulation","Neural Recording","Obstructive Sleep Apnea","Finite Element Model","Upper Airway Mechanics","Hypoglossal Nerve"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1081536516","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1081536516","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1081536516","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1081536516","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Durand, Dominique"]},{"key":"dc:creator","label":"Author","values":["Yoo, Paul B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2004-04-12"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Biomedical","Electrical Stimulation","Neural Recording","Obstructive Sleep Apnea","Finite Element Model","Upper Airway Mechanics","Hypoglossal Nerve"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1081536516"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["As an alternative to the myriad treatment methods (e.g., tracheostomy) that have been employed to alleviate the characteristic symptoms of obstructive sleep apnea (OSA), electrical stimulation of the hypoglossal (XII) nerve has been shown as a potentially effective therapeutic option. Despite significant improvements in upper airway (UAW) mechanics and reductions in the apnea plus hypopnea index (AHI; measure of OSA severity), inconsistent results (i.e., partial or no effect on AHI) have been observed for non-selective stimulation. In order to account for this unpredictable response to neural stimulation and to also generate a feedback signal to control therapeutic stimulation, a single nerve cuff electrode is presented as means to achieving these objectives. To this end, we first investigated the ability of the multi-contact flat-interface-nerve-electrode (FINE) to stimulate selectively the discrete branches of the beagle XII nerve. Using the recorded neural and muscular responses to electrical pulses delivered through the FINE, a selectivity index (0 ≤ SI ≤ 1) was used to show the degree of selectivity achieved with this electrode: 0.93 ± 0.03 (n = 5) and 0.88 ± 0.03 (n = 4), respectively. This was, in fact, similar to stimulating each individual branch: 0.91 ± 0.02 (n = 4). Second, the feasibility of using the FINE to record selectively the neural activity of the same nerve was studied via (1) a finite element model of a canine XII nerve and (2) comparison with experimental data. The results not only showed that the recording selectivity (SI; ability to distinguish two active sources) was a function of inter-fiber distance but that the minimum inter-fiber distance for this particular nerve electrode can be predicted at physiological signal-to-noise (SNR) levels (e.g., 0.54 mm at 2 dB). Finally, the effects of selective stimulation on the isolated beagle XII nerve showed that the most significant improvements in the UAW flow mechanics (i.e., R <sub>UAW</sub> and P <sub>crit</sub> ) are achieved through whole XII nerve stimulation and co-activation of the GG & HG/SG muscles during expiration and inspiration, respectively. Accordingly, non-selective control may be sufficient to achieve maximum therapeutic outcome."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","7.59 MB"]},{"key":"dc:title","label":"Title","values":["SELECTIVE STIMULATION AND RECORDING OF THE CANINE HYPOGLOSSAL NERVE FOR THE TREATMENT OF OBSTRUCTIVE SLEEP APNEA"]}]}],"canonical_facts":{"dc:contributor.advisor":["Durand, Dominique"],"dc:creator":["Yoo, Paul B."],"dc:date":["2004-04-12"],"dc:description":["As an alternative to the myriad treatment methods (e.g., tracheostomy) that have been employed to alleviate the characteristic symptoms of obstructive sleep apnea (OSA), electrical stimulation of the hypoglossal (XII) nerve has been shown as a potentially effective therapeutic option. Despite significant improvements in upper airway (UAW) mechanics and reductions in the apnea plus hypopnea index (AHI; measure of OSA severity), inconsistent results (i.e., partial or no effect on AHI) have been observed for non-selective stimulation. In order to account for this unpredictable response to neural stimulation and to also generate a feedback signal to control therapeutic stimulation, a single nerve cuff electrode is presented as means to achieving these objectives. To this end, we first investigated the ability of the multi-contact flat-interface-nerve-electrode (FINE) to stimulate selectively the discrete branches of the beagle XII nerve. Using the recorded neural and muscular responses to electrical pulses delivered through the FINE, a selectivity index (0 ≤ SI ≤ 1) was used to show the degree of selectivity achieved with this electrode: 0.93 ± 0.03 (n = 5) and 0.88 ± 0.03 (n = 4), respectively. This was, in fact, similar to stimulating each individual branch: 0.91 ± 0.02 (n = 4). Second, the feasibility of using the FINE to record selectively the neural activity of the same nerve was studied via (1) a finite element model of a canine XII nerve and (2) comparison with experimental data. The results not only showed that the recording selectivity (SI; ability to distinguish two active sources) was a function of inter-fiber distance but that the minimum inter-fiber distance for this particular nerve electrode can be predicted at physiological signal-to-noise (SNR) levels (e.g., 0.54 mm at 2 dB). Finally, the effects of selective stimulation on the isolated beagle XII nerve showed that the most significant improvements in the UAW flow mechanics (i.e., R <sub>UAW</sub> and P <sub>crit</sub> ) are achieved through whole XII nerve stimulation and co-activation of the GG & HG/SG muscles during expiration and inspiration, respectively. Accordingly, non-selective control may be sufficient to achieve maximum therapeutic outcome."],"dc:format":["application/pdf","7.59 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1081536516"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Biomedical","Electrical Stimulation","Neural Recording","Obstructive Sleep Apnea","Finite Element Model","Upper Airway Mechanics","Hypoglossal Nerve"],"dc:title":["SELECTIVE STIMULATION AND RECORDING OF THE CANINE HYPOGLOSSAL NERVE FOR THE TREATMENT OF OBSTRUCTIVE SLEEP APNEA"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:19Z"}