{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1081641430"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1081641430","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"An Electrode Array for Reversing the Recruitment Order of Peripheral Stimulation","abstract":"<p>Extracellular electrical stimulation of peripheral nerve activates large diameter fibers before small ones. Recruitment order from small to large diameters is more physiological and desirable in many applications. Current methods to solve this problem require long duration stimulus pulses leading to electrode corrosion. The hypothesis that selective activation of small axons can be achieved by reshaping the extracellular potential profile along axons using an array of electrodes was tested in computer simulations and animal experiments.</p><p>Simulations in homogenous medium using an array of 4 cathodes and 5 anodes with 0.75mm contact separation showed that large axons (13-17µm) (0.6-3.0mA) had higher stimulating threshold than small axons (2-7µm) (0.4-0.7mA) with 200µm axon-electrode distance and 10µs stimulus pulse. In finite element model of dog sacral root where the fiber diameter distribution was bimodal with peaks at 5 and 14 µm (389 axons), 5 and 7-contact arrays recruited 35% and 65% of small axons (<10 µm) when recruiting only 10% and 30% of larger axons. Effectiveness of 9 and 11-contact arrays was decreased with the presence of epineurium and perineurium. Pulsewidth of monophasic stimulation had no effect on the diameter selective stimulation of the array. For the biphasic pulse stimulation, amplitude of the second phase has to be set lower than the first phase to prevent the excitation of large axons.</p><p>Effect of electrode arrays of 5, 7, and 11 contacts on the recruitment order were tested in computer simulations and animal experiments using cat Lateral Gastrocnemius (LG) innervating both LG (10-14µm) and soleus (8-12µm) muscle groups. The results in computer simulations and animal experiments were consistent. Tripolar electrode activated LG before soleus, whereas the 5-contact array shifted the soleus recruitment curve to overlap with that of LG, and the 7 and 11 contacts reversed the recruitment order between LG and soleus. Effect of the 11-contact array was not highly reproducible experimentally. The arrays decreased the recruitment curve slope to only 10% that of tripolar electrode. The 5 and 7-contact array can be used to reverse the recruitment order of peripheral nerve stimulation.</p>","abstract_html":"&lt;p&gt;Extracellular electrical stimulation of peripheral nerve activates large diameter fibers before small ones. Recruitment order from small to large diameters is more physiological and desirable in many applications. Current methods to solve this problem require long duration stimulus pulses leading to electrode corrosion. The hypothesis that selective activation of small axons can be achieved by reshaping the extracellular potential profile along axons using an array of electrodes was tested in computer simulations and animal experiments.&lt;/p&gt;&lt;p&gt;Simulations in homogenous medium using an array of 4 cathodes and 5 anodes with 0.75mm contact separation showed that large axons (13-17µm) (0.6-3.0mA) had higher stimulating threshold than small axons (2-7µm) (0.4-0.7mA) with 200µm axon-electrode distance and 10µs stimulus pulse. In finite element model of dog sacral root where the fiber diameter distribution was bimodal with peaks at 5 and 14 µm (389 axons), 5 and 7-contact arrays recruited 35% and 65% of small axons (&lt;10 µm) when recruiting only 10% and 30% of larger axons. Effectiveness of 9 and 11-contact arrays was decreased with the presence of epineurium and perineurium. Pulsewidth of monophasic stimulation had no effect on the diameter selective stimulation of the array. For the biphasic pulse stimulation, amplitude of the second phase has to be set lower than the first phase to prevent the excitation of large axons.&lt;/p&gt;&lt;p&gt;Effect of electrode arrays of 5, 7, and 11 contacts on the recruitment order were tested in computer simulations and animal experiments using cat Lateral Gastrocnemius (LG) innervating both LG (10-14µm) and soleus (8-12µm) muscle groups. The results in computer simulations and animal experiments were consistent. Tripolar electrode activated LG before soleus, whereas the 5-contact array shifted the soleus recruitment curve to overlap with that of LG, and the 7 and 11 contacts reversed the recruitment order between LG and soleus. Effect of the 11-contact array was not highly reproducible experimentally. The arrays decreased the recruitment curve slope to only 10% that of tripolar electrode. The 5 and 7-contact array can be used to reverse the recruitment order of peripheral nerve stimulation.&lt;/p&gt;","abstract_has_math":false,"creators":["Lertmanorat, Zeng"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Durand, Dominique"],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-04-12","date_published":"2004-04-12","updated_at":"2026-11-27T04:14:19Z","subjects":["Engineering, Biomedical","neural prostheses","recruitment order","Selective nerve stimulation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1081641430","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1081641430","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1081641430","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1081641430","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Durand, Dominique"]},{"key":"dc:creator","label":"Author","values":["Lertmanorat, Zeng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2004-04-12"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Biomedical","neural prostheses","recruitment order","Selective nerve stimulation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1081641430"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Extracellular electrical stimulation of peripheral nerve activates large diameter fibers before small ones. Recruitment order from small to large diameters is more physiological and desirable in many applications. Current methods to solve this problem require long duration stimulus pulses leading to electrode corrosion. The hypothesis that selective activation of small axons can be achieved by reshaping the extracellular potential profile along axons using an array of electrodes was tested in computer simulations and animal experiments.</p><p>Simulations in homogenous medium using an array of 4 cathodes and 5 anodes with 0.75mm contact separation showed that large axons (13-17µm) (0.6-3.0mA) had higher stimulating threshold than small axons (2-7µm) (0.4-0.7mA) with 200µm axon-electrode distance and 10µs stimulus pulse. In finite element model of dog sacral root where the fiber diameter distribution was bimodal with peaks at 5 and 14 µm (389 axons), 5 and 7-contact arrays recruited 35% and 65% of small axons (<10 µm) when recruiting only 10% and 30% of larger axons. Effectiveness of 9 and 11-contact arrays was decreased with the presence of epineurium and perineurium. Pulsewidth of monophasic stimulation had no effect on the diameter selective stimulation of the array. For the biphasic pulse stimulation, amplitude of the second phase has to be set lower than the first phase to prevent the excitation of large axons.</p><p>Effect of electrode arrays of 5, 7, and 11 contacts on the recruitment order were tested in computer simulations and animal experiments using cat Lateral Gastrocnemius (LG) innervating both LG (10-14µm) and soleus (8-12µm) muscle groups. The results in computer simulations and animal experiments were consistent. Tripolar electrode activated LG before soleus, whereas the 5-contact array shifted the soleus recruitment curve to overlap with that of LG, and the 7 and 11 contacts reversed the recruitment order between LG and soleus. Effect of the 11-contact array was not highly reproducible experimentally. The arrays decreased the recruitment curve slope to only 10% that of tripolar electrode. The 5 and 7-contact array can be used to reverse the recruitment order of peripheral nerve stimulation.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.100","2.64 MB"]},{"key":"dc:title","label":"Title","values":["An Electrode Array for Reversing the Recruitment Order of Peripheral Stimulation"]}]}],"canonical_facts":{"dc:contributor.advisor":["Durand, Dominique"],"dc:creator":["Lertmanorat, Zeng"],"dc:date":["2004-04-12"],"dc:description":["<p>Extracellular electrical stimulation of peripheral nerve activates large diameter fibers before small ones. Recruitment order from small to large diameters is more physiological and desirable in many applications. Current methods to solve this problem require long duration stimulus pulses leading to electrode corrosion. The hypothesis that selective activation of small axons can be achieved by reshaping the extracellular potential profile along axons using an array of electrodes was tested in computer simulations and animal experiments.</p><p>Simulations in homogenous medium using an array of 4 cathodes and 5 anodes with 0.75mm contact separation showed that large axons (13-17µm) (0.6-3.0mA) had higher stimulating threshold than small axons (2-7µm) (0.4-0.7mA) with 200µm axon-electrode distance and 10µs stimulus pulse. In finite element model of dog sacral root where the fiber diameter distribution was bimodal with peaks at 5 and 14 µm (389 axons), 5 and 7-contact arrays recruited 35% and 65% of small axons (<10 µm) when recruiting only 10% and 30% of larger axons. Effectiveness of 9 and 11-contact arrays was decreased with the presence of epineurium and perineurium. Pulsewidth of monophasic stimulation had no effect on the diameter selective stimulation of the array. For the biphasic pulse stimulation, amplitude of the second phase has to be set lower than the first phase to prevent the excitation of large axons.</p><p>Effect of electrode arrays of 5, 7, and 11 contacts on the recruitment order were tested in computer simulations and animal experiments using cat Lateral Gastrocnemius (LG) innervating both LG (10-14µm) and soleus (8-12µm) muscle groups. The results in computer simulations and animal experiments were consistent. Tripolar electrode activated LG before soleus, whereas the 5-contact array shifted the soleus recruitment curve to overlap with that of LG, and the 7 and 11 contacts reversed the recruitment order between LG and soleus. Effect of the 11-contact array was not highly reproducible experimentally. The arrays decreased the recruitment curve slope to only 10% that of tripolar electrode. The 5 and 7-contact array can be used to reverse the recruitment order of peripheral nerve stimulation.</p>"],"dc:format":["application/pdf","p.100","2.64 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1081641430"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Biomedical","neural prostheses","recruitment order","Selective nerve stimulation"],"dc:title":["An Electrode Array for Reversing the Recruitment Order of Peripheral Stimulation"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:19Z"}