{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1109959500"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1109959500","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"An Optimization-Based Treatment Planner for Gamma Knife Radiosurgery","abstract":"This research addresses the planning of Gamma Knife radiotherapy, which is an alternative to treating a variety of brain abnormalities with surgery. The principal aim of this work is to develop an automated planning system that will make it simpler, less time consuming and hopefully more effective for the clinical personnel to develop treatment plans. Currently, treatment planning is a time-consuming task that involves an iterative process of shot selection, placement, and adjustment. Our goal is to replace the iterative part of the planning with an optimization-based real-time planner. Our strategy is to: (1) automate initial shot selection and placement using a combined process of skeletonization and bin-covering, (2) optimize the exposure time for each shot to improve the target coverage while minimizing toxicity to the surrounding tissues, and (3) fine-tune the shot configuration by adjusting shot locations, and adding or deleting shots to further improve the balance between target coverage and normal tissue toxicity. The efficiency and effectiveness of our approach is derived from (1) the use of skeletonization and bin-covering to provide good starting point for the development of the plan, (2) the easy-to-solve linear fractional program that explicitly accounts for the dual objectives of maximizing target coverage while minimizing toxicity, at the same time accounting for dose-renormalization and (3) the fine-tuning step that explicitly accounts for shot overlapping, dose renormalization, and target shape to make determining of hot spots and estimating the effects of shot movement, addition and/or deletion possible. The planning system has been implemented on a Windows-based platform and tested using clinical cases from the standard Gamma Knife treatment model as well as the automatic positioning system (APS) model. The planner consistently produces, in 1-2 minutes, plans with dose conformity compatible to manual plans normally created in 1-4 hours.","abstract_html":"This research addresses the planning of Gamma Knife radiotherapy, which is an alternative to treating a variety of brain abnormalities with surgery. The principal aim of this work is to develop an automated planning system that will make it simpler, less time consuming and hopefully more effective for the clinical personnel to develop treatment plans. Currently, treatment planning is a time-consuming task that involves an iterative process of shot selection, placement, and adjustment. Our goal is to replace the iterative part of the planning with an optimization-based real-time planner. Our strategy is to: (1) automate initial shot selection and placement using a combined process of skeletonization and bin-covering, (2) optimize the exposure time for each shot to improve the target coverage while minimizing toxicity to the surrounding tissues, and (3) fine-tune the shot configuration by adjusting shot locations, and adding or deleting shots to further improve the balance between target coverage and normal tissue toxicity. The efficiency and effectiveness of our approach is derived from (1) the use of skeletonization and bin-covering to provide good starting point for the development of the plan, (2) the easy-to-solve linear fractional program that explicitly accounts for the dual objectives of maximizing target coverage while minimizing toxicity, at the same time accounting for dose-renormalization and (3) the fine-tuning step that explicitly accounts for shot overlapping, dose renormalization, and target shape to make determining of hot spots and estimating the effects of shot movement, addition and/or deletion possible. The planning system has been implemented on a Windows-based platform and tested using clinical cases from the standard Gamma Knife treatment model as well as the automatic positioning system (APS) model. The planner consistently produces, in 1-2 minutes, plans with dose conformity compatible to manual plans normally created in 1-4 hours.","abstract_has_math":false,"creators":["Jitprapaikulsarn, Suradet"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Systems and Control Engineering","degree_department":null,"school":null,"contributors":["Chankong, Vira"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-03-04","date_published":"2005-03-04","updated_at":"2026-11-26T03:17:02Z","subjects":["Engineering, System Science","Optimization, Gamma Knife, Multi-objective optimization, Fractional Programming, Mixed-Integer Nonlinear Programming, Bin-Covering,","Re-normalization, Shot overlapping"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1109959500","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1109959500","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1109959500","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1109959500","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Chankong, Vira"]},{"key":"dc:creator","label":"Author","values":["Jitprapaikulsarn, Suradet"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005-03-04"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Systems and Control Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, System Science","Optimization, Gamma Knife, Multi-objective optimization, Fractional Programming, Mixed-Integer Nonlinear Programming, Bin-Covering,","Re-normalization, Shot overlapping"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1109959500"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This research addresses the planning of Gamma Knife radiotherapy, which is an alternative to treating a variety of brain abnormalities with surgery. The principal aim of this work is to develop an automated planning system that will make it simpler, less time consuming and hopefully more effective for the clinical personnel to develop treatment plans. Currently, treatment planning is a time-consuming task that involves an iterative process of shot selection, placement, and adjustment. Our goal is to replace the iterative part of the planning with an optimization-based real-time planner. Our strategy is to: (1) automate initial shot selection and placement using a combined process of skeletonization and bin-covering, (2) optimize the exposure time for each shot to improve the target coverage while minimizing toxicity to the surrounding tissues, and (3) fine-tune the shot configuration by adjusting shot locations, and adding or deleting shots to further improve the balance between target coverage and normal tissue toxicity. The efficiency and effectiveness of our approach is derived from (1) the use of skeletonization and bin-covering to provide good starting point for the development of the plan, (2) the easy-to-solve linear fractional program that explicitly accounts for the dual objectives of maximizing target coverage while minimizing toxicity, at the same time accounting for dose-renormalization and (3) the fine-tuning step that explicitly accounts for shot overlapping, dose renormalization, and target shape to make determining of hot spots and estimating the effects of shot movement, addition and/or deletion possible. The planning system has been implemented on a Windows-based platform and tested using clinical cases from the standard Gamma Knife treatment model as well as the automatic positioning system (APS) model. The planner consistently produces, in 1-2 minutes, plans with dose conformity compatible to manual plans normally created in 1-4 hours."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","3.73 MB"]},{"key":"dc:title","label":"Title","values":["An Optimization-Based Treatment Planner for Gamma Knife Radiosurgery"]}]}],"canonical_facts":{"dc:contributor":["Chankong, Vira"],"dc:creator":["Jitprapaikulsarn, Suradet"],"dc:date":["2005-03-04"],"dc:description":["This research addresses the planning of Gamma Knife radiotherapy, which is an alternative to treating a variety of brain abnormalities with surgery. The principal aim of this work is to develop an automated planning system that will make it simpler, less time consuming and hopefully more effective for the clinical personnel to develop treatment plans. Currently, treatment planning is a time-consuming task that involves an iterative process of shot selection, placement, and adjustment. Our goal is to replace the iterative part of the planning with an optimization-based real-time planner. Our strategy is to: (1) automate initial shot selection and placement using a combined process of skeletonization and bin-covering, (2) optimize the exposure time for each shot to improve the target coverage while minimizing toxicity to the surrounding tissues, and (3) fine-tune the shot configuration by adjusting shot locations, and adding or deleting shots to further improve the balance between target coverage and normal tissue toxicity. The efficiency and effectiveness of our approach is derived from (1) the use of skeletonization and bin-covering to provide good starting point for the development of the plan, (2) the easy-to-solve linear fractional program that explicitly accounts for the dual objectives of maximizing target coverage while minimizing toxicity, at the same time accounting for dose-renormalization and (3) the fine-tuning step that explicitly accounts for shot overlapping, dose renormalization, and target shape to make determining of hot spots and estimating the effects of shot movement, addition and/or deletion possible. The planning system has been implemented on a Windows-based platform and tested using clinical cases from the standard Gamma Knife treatment model as well as the automatic positioning system (APS) model. The planner consistently produces, in 1-2 minutes, plans with dose conformity compatible to manual plans normally created in 1-4 hours."],"dc:format":["application/pdf","3.73 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1109959500"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, System Science","Optimization, Gamma Knife, Multi-objective optimization, Fractional Programming, Mixed-Integer Nonlinear Programming, Bin-Covering,","Re-normalization, Shot overlapping"],"dc:title":["An Optimization-Based Treatment Planner for Gamma Knife Radiosurgery"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Systems and Control Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:17:02Z"}