{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1121349361"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1121349361","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Electrochemical Characterization of Lubricants for Microfabricated Sensor Applications","abstract":"<p>The lubrication and automotive industries are seeking on-line sensors capable of determining the chemical condition and degree of degradation of industrial lubricants. Further development in understanding fundamental electrochemical characteristics of lubricants and their contaminants will allow for improvements in monitoring the performance of existent and the formulation of new advanced lubricants. Contamination by a few hundred ppm of water can cause detrimental changes in the lubricating properties of engine oil. Levels of acidity and basicity are parameters common to a wide variety of industrial fluids and are closely related to rate of lubricant oxidative breakdown. Related to the rate of lubricant oxidative breakdown is the formation and build-up of soot, which also diminishes lubricant quality.</p> <p>Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and chronopotentiometry (CP) were employed as a basis for on-line electrochemical sensors for composition analysis of fully formulated industrial lubricants. These electrochemical techniques appeared as powerful yet inexpensive tools specifically capable of on-line detection and monitoring of major contaminants of typical industrial lubricants as well as oxidative degradation. Microelectromechanical systems (MEMS) technology was employed for the design and fabrication of these electrochemical sensors.</p> <p>The application of these techniques for the analysis of the electrochemical properties of industrial lubricants focused on establishing relationships between lubricant chemical composition and experimental data. Presented data demonstrated a need to rely on several output parameters collected over wide frequency, electrochemical potential, temperature, and electrode geometry ranges in order to assess complex processes and decomposition pathways occurring both at the electrode interface and in the bulk solution. An equivalent circuit model was developed to describe the electrochemical structure of a typical industrial lubricant. The model was used for the analysis of electrochemical results as a reflection of chemical composition and changes in the system.</p> <p>Following this, a series of MEMS-based interdigitated sensors were developed and tested in typical industrial lubricants. Results showed that performance of the interdigitated sensors was consistent with the design equations; however, the comparison of EIS results using the interdigitated prototypes and the solid parallel plate electrodes showed that the prototype design needs further optimization.</p>","abstract_html":"&lt;p&gt;The lubrication and automotive industries are seeking on-line sensors capable of determining the chemical condition and degree of degradation of industrial lubricants. Further development in understanding fundamental electrochemical characteristics of lubricants and their contaminants will allow for improvements in monitoring the performance of existent and the formulation of new advanced lubricants. Contamination by a few hundred ppm of water can cause detrimental changes in the lubricating properties of engine oil. Levels of acidity and basicity are parameters common to a wide variety of industrial fluids and are closely related to rate of lubricant oxidative breakdown. Related to the rate of lubricant oxidative breakdown is the formation and build-up of soot, which also diminishes lubricant quality.&lt;/p&gt; &lt;p&gt;Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and chronopotentiometry (CP) were employed as a basis for on-line electrochemical sensors for composition analysis of fully formulated industrial lubricants. These electrochemical techniques appeared as powerful yet inexpensive tools specifically capable of on-line detection and monitoring of major contaminants of typical industrial lubricants as well as oxidative degradation. Microelectromechanical systems (MEMS) technology was employed for the design and fabrication of these electrochemical sensors.&lt;/p&gt; &lt;p&gt;The application of these techniques for the analysis of the electrochemical properties of industrial lubricants focused on establishing relationships between lubricant chemical composition and experimental data. Presented data demonstrated a need to rely on several output parameters collected over wide frequency, electrochemical potential, temperature, and electrode geometry ranges in order to assess complex processes and decomposition pathways occurring both at the electrode interface and in the bulk solution. An equivalent circuit model was developed to describe the electrochemical structure of a typical industrial lubricant. The model was used for the analysis of electrochemical results as a reflection of chemical composition and changes in the system.&lt;/p&gt; &lt;p&gt;Following this, a series of MEMS-based interdigitated sensors were developed and tested in typical industrial lubricants. Results showed that performance of the interdigitated sensors was consistent with the design equations; however, the comparison of EIS results using the interdigitated prototypes and the solid parallel plate electrodes showed that the prototype design needs further optimization.&lt;/p&gt;","abstract_has_math":false,"creators":["Smiechowski, Matthew F."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Liu, Chung-Chiun"],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-07-15","date_published":"2005-07-15","updated_at":"2026-11-27T04:14:19Z","subjects":["Engineering, Chemical","Electrochemical Sensors","Lubricant Analysis","Lubricant Degredation","Microfabrication","Impedance Spectroscopy"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1121349361","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1121349361","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1121349361","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1121349361","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Liu, Chung-Chiun"]},{"key":"dc:creator","label":"Author","values":["Smiechowski, Matthew F."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005-07-15"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Chemical","Electrochemical Sensors","Lubricant Analysis","Lubricant Degredation","Microfabrication","Impedance Spectroscopy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1121349361"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>The lubrication and automotive industries are seeking on-line sensors capable of determining the chemical condition and degree of degradation of industrial lubricants. Further development in understanding fundamental electrochemical characteristics of lubricants and their contaminants will allow for improvements in monitoring the performance of existent and the formulation of new advanced lubricants. Contamination by a few hundred ppm of water can cause detrimental changes in the lubricating properties of engine oil. Levels of acidity and basicity are parameters common to a wide variety of industrial fluids and are closely related to rate of lubricant oxidative breakdown. Related to the rate of lubricant oxidative breakdown is the formation and build-up of soot, which also diminishes lubricant quality.</p> <p>Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and chronopotentiometry (CP) were employed as a basis for on-line electrochemical sensors for composition analysis of fully formulated industrial lubricants. These electrochemical techniques appeared as powerful yet inexpensive tools specifically capable of on-line detection and monitoring of major contaminants of typical industrial lubricants as well as oxidative degradation. Microelectromechanical systems (MEMS) technology was employed for the design and fabrication of these electrochemical sensors.</p> <p>The application of these techniques for the analysis of the electrochemical properties of industrial lubricants focused on establishing relationships between lubricant chemical composition and experimental data. Presented data demonstrated a need to rely on several output parameters collected over wide frequency, electrochemical potential, temperature, and electrode geometry ranges in order to assess complex processes and decomposition pathways occurring both at the electrode interface and in the bulk solution. An equivalent circuit model was developed to describe the electrochemical structure of a typical industrial lubricant. The model was used for the analysis of electrochemical results as a reflection of chemical composition and changes in the system.</p> <p>Following this, a series of MEMS-based interdigitated sensors were developed and tested in typical industrial lubricants. Results showed that performance of the interdigitated sensors was consistent with the design equations; however, the comparison of EIS results using the interdigitated prototypes and the solid parallel plate electrodes showed that the prototype design needs further optimization.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","2.71 MB"]},{"key":"dc:title","label":"Title","values":["Electrochemical Characterization of Lubricants for Microfabricated Sensor Applications"]}]}],"canonical_facts":{"dc:contributor.advisor":["Liu, Chung-Chiun"],"dc:creator":["Smiechowski, Matthew F."],"dc:date":["2005-07-15"],"dc:description":["<p>The lubrication and automotive industries are seeking on-line sensors capable of determining the chemical condition and degree of degradation of industrial lubricants. Further development in understanding fundamental electrochemical characteristics of lubricants and their contaminants will allow for improvements in monitoring the performance of existent and the formulation of new advanced lubricants. Contamination by a few hundred ppm of water can cause detrimental changes in the lubricating properties of engine oil. Levels of acidity and basicity are parameters common to a wide variety of industrial fluids and are closely related to rate of lubricant oxidative breakdown. Related to the rate of lubricant oxidative breakdown is the formation and build-up of soot, which also diminishes lubricant quality.</p> <p>Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and chronopotentiometry (CP) were employed as a basis for on-line electrochemical sensors for composition analysis of fully formulated industrial lubricants. These electrochemical techniques appeared as powerful yet inexpensive tools specifically capable of on-line detection and monitoring of major contaminants of typical industrial lubricants as well as oxidative degradation. Microelectromechanical systems (MEMS) technology was employed for the design and fabrication of these electrochemical sensors.</p> <p>The application of these techniques for the analysis of the electrochemical properties of industrial lubricants focused on establishing relationships between lubricant chemical composition and experimental data. Presented data demonstrated a need to rely on several output parameters collected over wide frequency, electrochemical potential, temperature, and electrode geometry ranges in order to assess complex processes and decomposition pathways occurring both at the electrode interface and in the bulk solution. An equivalent circuit model was developed to describe the electrochemical structure of a typical industrial lubricant. The model was used for the analysis of electrochemical results as a reflection of chemical composition and changes in the system.</p> <p>Following this, a series of MEMS-based interdigitated sensors were developed and tested in typical industrial lubricants. Results showed that performance of the interdigitated sensors was consistent with the design equations; however, the comparison of EIS results using the interdigitated prototypes and the solid parallel plate electrodes showed that the prototype design needs further optimization.</p>"],"dc:format":["application/pdf","2.71 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1121349361"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Chemical","Electrochemical Sensors","Lubricant Analysis","Lubricant Degredation","Microfabrication","Impedance Spectroscopy"],"dc:title":["Electrochemical Characterization of Lubricants for Microfabricated Sensor Applications"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:19Z"}