{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1144340892"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1144340892","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"SINGLE PARTICLE MICROELECTRODES AND MICROBATTERIES: FUNDAMENTAL STUDIES","abstract":"Novel methods are herein described for the micromanipulation and subsequent in situ, real-time characterization of individual ìm size particles of electrochemically active materials under potential control. One tactic relies on the use of a micropipette to capture by suction single particles, which are then attached to the surface of a glass-encased microelectrode held in position by a small glass rod in the form of truncated cone. This configuration allows for particles to be placed directly beneath the microscope objective enabling visual and spectroscopic monitoring during electrochemical measurements. Illustrations are provided for particles of spherical Ni hydroxide, S-Ni(OH)2, in alkaline solutions, which following activation at fairly positive potentials, yielded an electrochemical response characteristic of Ni(OH)2 in more conventional electrode configurations. The darkening of the translucent virgin S-Ni(OH)2 allowed for the spatio-temporal evolution of charge flow within the microparticle to be monitored in real time during the first anodic scan. Similar techniques made it possible to monitor in situ of changes in the electrical resistance of a single, spherical (S-)Ni(OH)2 microparticle electrode as a function of its state of charge. The general approach involves application of 1-2 mV across, and measuring the current through the particle either at a fixed state of charge (static) or during a linear voltammetric scan (dynamic). The data obtained for activated S-Ni(OH)2 microparticles agreed very well with values reported in the literature measured by other means, whereas oxidation of the material yielded as expected a sizable increase in conductivity. Extension of these procedures also permitted the assembly and electrochemical characterization of Zn|MnO2 and Ni|MH alkaline batteries incorporating single microparticles of the active materials. As evidenced by the data collected, the voltage-time profiles for constant current operation for both types of devices were found to be similar to those of commercially available batteries involving the same chemistries. The flow of charge between two particles was also studied in situ by employing a glass microtube to restrict movement of the particles in contact with each other and Au microrod current collector electrodes. The results indicate that the flow of charge across the interparticle boundary is greatly hindered.","abstract_html":"Novel methods are herein described for the micromanipulation and subsequent in situ, real-time characterization of individual ìm size particles of electrochemically active materials under potential control. One tactic relies on the use of a micropipette to capture by suction single particles, which are then attached to the surface of a glass-encased microelectrode held in position by a small glass rod in the form of truncated cone. This configuration allows for particles to be placed directly beneath the microscope objective enabling visual and spectroscopic monitoring during electrochemical measurements. Illustrations are provided for particles of spherical Ni hydroxide, S-Ni(OH)2, in alkaline solutions, which following activation at fairly positive potentials, yielded an electrochemical response characteristic of Ni(OH)2 in more conventional electrode configurations. The darkening of the translucent virgin S-Ni(OH)2 allowed for the spatio-temporal evolution of charge flow within the microparticle to be monitored in real time during the first anodic scan. Similar techniques made it possible to monitor in situ of changes in the electrical resistance of a single, spherical (S-)Ni(OH)2 microparticle electrode as a function of its state of charge. The general approach involves application of 1-2 mV across, and measuring the current through the particle either at a fixed state of charge (static) or during a linear voltammetric scan (dynamic). The data obtained for activated S-Ni(OH)2 microparticles agreed very well with values reported in the literature measured by other means, whereas oxidation of the material yielded as expected a sizable increase in conductivity. Extension of these procedures also permitted the assembly and electrochemical characterization of Zn|MnO2 and Ni|MH alkaline batteries incorporating single microparticles of the active materials. As evidenced by the data collected, the voltage-time profiles for constant current operation for both types of devices were found to be similar to those of commercially available batteries involving the same chemistries. The flow of charge between two particles was also studied in situ by employing a glass microtube to restrict movement of the particles in contact with each other and Au microrod current collector electrodes. The results indicate that the flow of charge across the interparticle boundary is greatly hindered.","abstract_has_math":false,"creators":["Palencsar, Iozsef Attila"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":["Scherson, Daniel"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006-04-07","date_published":"2006-04-07","updated_at":"2026-11-26T03:17:02Z","subjects":["Chemistry, Physical","single particle","micromanipulation","nickel hydroxide","batteries","microbatteries","electrochemistry"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1144340892","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1144340892","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1144340892","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1144340892","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Scherson, Daniel"]},{"key":"dc:creator","label":"Author","values":["Palencsar, Iozsef Attila"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2006-04-07"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemistry, Physical","single particle","micromanipulation","nickel hydroxide","batteries","microbatteries","electrochemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1144340892"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Novel methods are herein described for the micromanipulation and subsequent in situ, real-time characterization of individual ìm size particles of electrochemically active materials under potential control. One tactic relies on the use of a micropipette to capture by suction single particles, which are then attached to the surface of a glass-encased microelectrode held in position by a small glass rod in the form of truncated cone. This configuration allows for particles to be placed directly beneath the microscope objective enabling visual and spectroscopic monitoring during electrochemical measurements. Illustrations are provided for particles of spherical Ni hydroxide, S-Ni(OH)2, in alkaline solutions, which following activation at fairly positive potentials, yielded an electrochemical response characteristic of Ni(OH)2 in more conventional electrode configurations. The darkening of the translucent virgin S-Ni(OH)2 allowed for the spatio-temporal evolution of charge flow within the microparticle to be monitored in real time during the first anodic scan. Similar techniques made it possible to monitor in situ of changes in the electrical resistance of a single, spherical (S-)Ni(OH)2 microparticle electrode as a function of its state of charge. The general approach involves application of 1-2 mV across, and measuring the current through the particle either at a fixed state of charge (static) or during a linear voltammetric scan (dynamic). The data obtained for activated S-Ni(OH)2 microparticles agreed very well with values reported in the literature measured by other means, whereas oxidation of the material yielded as expected a sizable increase in conductivity. Extension of these procedures also permitted the assembly and electrochemical characterization of Zn|MnO2 and Ni|MH alkaline batteries incorporating single microparticles of the active materials. As evidenced by the data collected, the voltage-time profiles for constant current operation for both types of devices were found to be similar to those of commercially available batteries involving the same chemistries. The flow of charge between two particles was also studied in situ by employing a glass microtube to restrict movement of the particles in contact with each other and Au microrod current collector electrodes. The results indicate that the flow of charge across the interparticle boundary is greatly hindered."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.100","2.68 MB"]},{"key":"dc:title","label":"Title","values":["SINGLE PARTICLE MICROELECTRODES AND MICROBATTERIES: FUNDAMENTAL STUDIES"]}]}],"canonical_facts":{"dc:contributor":["Scherson, Daniel"],"dc:creator":["Palencsar, Iozsef Attila"],"dc:date":["2006-04-07"],"dc:description":["Novel methods are herein described for the micromanipulation and subsequent in situ, real-time characterization of individual ìm size particles of electrochemically active materials under potential control. One tactic relies on the use of a micropipette to capture by suction single particles, which are then attached to the surface of a glass-encased microelectrode held in position by a small glass rod in the form of truncated cone. This configuration allows for particles to be placed directly beneath the microscope objective enabling visual and spectroscopic monitoring during electrochemical measurements. Illustrations are provided for particles of spherical Ni hydroxide, S-Ni(OH)2, in alkaline solutions, which following activation at fairly positive potentials, yielded an electrochemical response characteristic of Ni(OH)2 in more conventional electrode configurations. The darkening of the translucent virgin S-Ni(OH)2 allowed for the spatio-temporal evolution of charge flow within the microparticle to be monitored in real time during the first anodic scan. Similar techniques made it possible to monitor in situ of changes in the electrical resistance of a single, spherical (S-)Ni(OH)2 microparticle electrode as a function of its state of charge. The general approach involves application of 1-2 mV across, and measuring the current through the particle either at a fixed state of charge (static) or during a linear voltammetric scan (dynamic). The data obtained for activated S-Ni(OH)2 microparticles agreed very well with values reported in the literature measured by other means, whereas oxidation of the material yielded as expected a sizable increase in conductivity. Extension of these procedures also permitted the assembly and electrochemical characterization of Zn|MnO2 and Ni|MH alkaline batteries incorporating single microparticles of the active materials. As evidenced by the data collected, the voltage-time profiles for constant current operation for both types of devices were found to be similar to those of commercially available batteries involving the same chemistries. The flow of charge between two particles was also studied in situ by employing a glass microtube to restrict movement of the particles in contact with each other and Au microrod current collector electrodes. The results indicate that the flow of charge across the interparticle boundary is greatly hindered."],"dc:format":["application/pdf","p.100","2.68 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1144340892"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Chemistry, Physical","single particle","micromanipulation","nickel hydroxide","batteries","microbatteries","electrochemistry"],"dc:title":["SINGLE PARTICLE MICROELECTRODES AND MICROBATTERIES: FUNDAMENTAL STUDIES"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:17:02Z"}