{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1144703489"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1144703489","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Optical Coherence Tomography for the Screening of Donor Corneas and Examination of the Retinal Nerve Fiber Directional Reflectance","abstract":"<p>Optical coherence tomography (OCT) is a high resolution, non-invasive imaging technology that employs light to create detailed images of the body. In medicine, OCT is most widely used in ophthalmology to create high resolution images of the cornea and the retina.</p><p>The group index of cornea, rather than phase refractive index, is required for thickness calculations with optical coherence tomography (OCT). Recent advances with high speed OCT at 1.3 µm make index measurement at this wavelength of great interest. Group indices of 3 human eye bank corneas were measured in vitro using optical low-coherence reflectometry. Measurements were made in a calibrated cuvette filled with a preservation medium to maintain proper corneal hydration. Group indices were calculated from the optical path lengths measured. The corneal group index was 1.389 ± 0.004 (average ± standard deviation).</p><p>The rising popularity of refractive surgery presents a dilemma for eye banks. Surgically modified corneas, which are difficult to identify and non-transplantable, are being harvested and undergoing transplantation. We construct an OCT system specifically for examination of eye bank donor corneas. Analysis of 24 normal corneas and 5 LASIK corneas show that anterior corneal curvature is the best parameter for discriminating between normal corneas and LASIK corneas (p = 0.023).</p><p>Glaucoma is the second leading cause of blindness in the world today. Early detection is essential to prevent visual loss. The retinal nerve fiber layer (RNFL), which degenerates in glaucoma, reflects light preferentially in certain directions and this directional reflectance can potentially provide a signal of its health. We demonstrate the use of an OCT variant that probes multiple incidence angles to examine the fixed rat retinal nerve fiber layer (RNFL). By doing so, we demonstrate the feasibility of measuring the directional reflectance of the rat RNFL <i>in vitro</i> using OCT. This is the first step towards developing a clinical system that can be used to compare normal eyes and glaucomatous eyes.</p>","abstract_html":"&lt;p&gt;Optical coherence tomography (OCT) is a high resolution, non-invasive imaging technology that employs light to create detailed images of the body. In medicine, OCT is most widely used in ophthalmology to create high resolution images of the cornea and the retina.&lt;/p&gt;&lt;p&gt;The group index of cornea, rather than phase refractive index, is required for thickness calculations with optical coherence tomography (OCT). Recent advances with high speed OCT at 1.3 µm make index measurement at this wavelength of great interest. Group indices of 3 human eye bank corneas were measured in vitro using optical low-coherence reflectometry. Measurements were made in a calibrated cuvette filled with a preservation medium to maintain proper corneal hydration. Group indices were calculated from the optical path lengths measured. The corneal group index was 1.389 ± 0.004 (average ± standard deviation).&lt;/p&gt;&lt;p&gt;The rising popularity of refractive surgery presents a dilemma for eye banks. Surgically modified corneas, which are difficult to identify and non-transplantable, are being harvested and undergoing transplantation. We construct an OCT system specifically for examination of eye bank donor corneas. Analysis of 24 normal corneas and 5 LASIK corneas show that anterior corneal curvature is the best parameter for discriminating between normal corneas and LASIK corneas (p = 0.023).&lt;/p&gt;&lt;p&gt;Glaucoma is the second leading cause of blindness in the world today. Early detection is essential to prevent visual loss. The retinal nerve fiber layer (RNFL), which degenerates in glaucoma, reflects light preferentially in certain directions and this directional reflectance can potentially provide a signal of its health. We demonstrate the use of an OCT variant that probes multiple incidence angles to examine the fixed rat retinal nerve fiber layer (RNFL). By doing so, we demonstrate the feasibility of measuring the directional reflectance of the rat RNFL &lt;i&gt;in vitro&lt;/i&gt; using OCT. This is the first step towards developing a clinical system that can be used to compare normal eyes and glaucomatous eyes.&lt;/p&gt;","abstract_has_math":false,"creators":["Lin, Roger Chin"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Rollins, Andrew"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006-04-11","date_published":"2006-04-11","updated_at":"2026-11-26T03:17:16Z","subjects":["Engineering, Biomedical","optical coherence tomography","cornea","eye bank","retina","refractive index","group index","retinal nerve fibers"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1144703489","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1144703489","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1144703489","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1144703489","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Rollins, Andrew"]},{"key":"dc:creator","label":"Author","values":["Lin, Roger Chin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2006-04-11"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Biomedical","optical coherence tomography","cornea","eye bank","retina","refractive index","group index","retinal nerve fibers"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1144703489"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Optical coherence tomography (OCT) is a high resolution, non-invasive imaging technology that employs light to create detailed images of the body. In medicine, OCT is most widely used in ophthalmology to create high resolution images of the cornea and the retina.</p><p>The group index of cornea, rather than phase refractive index, is required for thickness calculations with optical coherence tomography (OCT). Recent advances with high speed OCT at 1.3 µm make index measurement at this wavelength of great interest. Group indices of 3 human eye bank corneas were measured in vitro using optical low-coherence reflectometry. Measurements were made in a calibrated cuvette filled with a preservation medium to maintain proper corneal hydration. Group indices were calculated from the optical path lengths measured. The corneal group index was 1.389 ± 0.004 (average ± standard deviation).</p><p>The rising popularity of refractive surgery presents a dilemma for eye banks. Surgically modified corneas, which are difficult to identify and non-transplantable, are being harvested and undergoing transplantation. We construct an OCT system specifically for examination of eye bank donor corneas. Analysis of 24 normal corneas and 5 LASIK corneas show that anterior corneal curvature is the best parameter for discriminating between normal corneas and LASIK corneas (p = 0.023).</p><p>Glaucoma is the second leading cause of blindness in the world today. Early detection is essential to prevent visual loss. The retinal nerve fiber layer (RNFL), which degenerates in glaucoma, reflects light preferentially in certain directions and this directional reflectance can potentially provide a signal of its health. We demonstrate the use of an OCT variant that probes multiple incidence angles to examine the fixed rat retinal nerve fiber layer (RNFL). By doing so, we demonstrate the feasibility of measuring the directional reflectance of the rat RNFL <i>in vitro</i> using OCT. This is the first step towards developing a clinical system that can be used to compare normal eyes and glaucomatous eyes.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.118","2.45 MB"]},{"key":"dc:title","label":"Title","values":["Optical Coherence Tomography for the Screening of Donor Corneas and Examination of the Retinal Nerve Fiber Directional Reflectance"]}]}],"canonical_facts":{"dc:contributor":["Rollins, Andrew"],"dc:creator":["Lin, Roger Chin"],"dc:date":["2006-04-11"],"dc:description":["<p>Optical coherence tomography (OCT) is a high resolution, non-invasive imaging technology that employs light to create detailed images of the body. In medicine, OCT is most widely used in ophthalmology to create high resolution images of the cornea and the retina.</p><p>The group index of cornea, rather than phase refractive index, is required for thickness calculations with optical coherence tomography (OCT). Recent advances with high speed OCT at 1.3 µm make index measurement at this wavelength of great interest. Group indices of 3 human eye bank corneas were measured in vitro using optical low-coherence reflectometry. Measurements were made in a calibrated cuvette filled with a preservation medium to maintain proper corneal hydration. Group indices were calculated from the optical path lengths measured. The corneal group index was 1.389 ± 0.004 (average ± standard deviation).</p><p>The rising popularity of refractive surgery presents a dilemma for eye banks. Surgically modified corneas, which are difficult to identify and non-transplantable, are being harvested and undergoing transplantation. We construct an OCT system specifically for examination of eye bank donor corneas. Analysis of 24 normal corneas and 5 LASIK corneas show that anterior corneal curvature is the best parameter for discriminating between normal corneas and LASIK corneas (p = 0.023).</p><p>Glaucoma is the second leading cause of blindness in the world today. Early detection is essential to prevent visual loss. The retinal nerve fiber layer (RNFL), which degenerates in glaucoma, reflects light preferentially in certain directions and this directional reflectance can potentially provide a signal of its health. We demonstrate the use of an OCT variant that probes multiple incidence angles to examine the fixed rat retinal nerve fiber layer (RNFL). By doing so, we demonstrate the feasibility of measuring the directional reflectance of the rat RNFL <i>in vitro</i> using OCT. This is the first step towards developing a clinical system that can be used to compare normal eyes and glaucomatous eyes.</p>"],"dc:format":["application/pdf","p.118","2.45 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1144703489"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Biomedical","optical coherence tomography","cornea","eye bank","retina","refractive index","group index","retinal nerve fibers"],"dc:title":["Optical Coherence Tomography for the Screening of Donor Corneas and Examination of the Retinal Nerve Fiber Directional Reflectance"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:17:16Z"}