{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1155913518"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1155913518","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Quantitative Image Quality Evaluation of Fast Magnetic Resonance Imaging","abstract":"Magnetic resonance imaging (MRI) has been widely used in the diagnosis and treatment of various diseases. The principle of encoding object contrast in the resonance spectrum gives MRI almost unlimited ways to acquire and reconstruct an image, but at the same time, arises the problem of how to effectively evaluate and optimize these parameters and methods. The perceptual difference model (CASE-PDM) is a quantitative image quality evaluation tool developed in our lab and has been successfully applied to several applications of MRI. It determines the visual difference between a high quality reference image and a more quickly obtained, but possibly degraded, MR image. A low CASE-PDM score indicates similarity of the images, and there is a threshold, below which, one cannot detect a difference between the two. The goal of our research is to use the CASE-PDM model to evaluate the image quality in fast MRI and to optimize the parameters. Two Human subject experiments, DSCQS and ADF, were designed and performed to validate the CASE-PDM model. The CASE-PDM predictions are closely correlated with the human subjects predictions, for both low-degradation and high-degradation images. We also found CASE-PDM threshold values that correspond to a “non-perceptible” difference. Using the above validation results, we focused on important variables in fast MR imaging, especially in spiral MRI and advanced parallel MRI techniques, including the SENSE regularization techniques and the GRAPPA reconstruction techniques. Data was generated from real scanners or simulated from the digital phantoms. Various acquisition parameters and reconstruction algorithms were combined to generate thousands of images for each application. CASE-PDM was used to quantitatively compare those images, and the CASE-PDM scores was analyzed statistically to give helpful hints for the engineers. In addition, a new modification of GRAPPA method called Robust GRAPPA was proposed. Robust GRAPPA was compared with conventional GRAPPA and obvious improvement in image quality was observed.","abstract_html":"Magnetic resonance imaging (MRI) has been widely used in the diagnosis and treatment of various diseases. The principle of encoding object contrast in the resonance spectrum gives MRI almost unlimited ways to acquire and reconstruct an image, but at the same time, arises the problem of how to effectively evaluate and optimize these parameters and methods. The perceptual difference model (CASE-PDM) is a quantitative image quality evaluation tool developed in our lab and has been successfully applied to several applications of MRI. It determines the visual difference between a high quality reference image and a more quickly obtained, but possibly degraded, MR image. A low CASE-PDM score indicates similarity of the images, and there is a threshold, below which, one cannot detect a difference between the two. The goal of our research is to use the CASE-PDM model to evaluate the image quality in fast MRI and to optimize the parameters. Two Human subject experiments, DSCQS and ADF, were designed and performed to validate the CASE-PDM model. The CASE-PDM predictions are closely correlated with the human subjects predictions, for both low-degradation and high-degradation images. We also found CASE-PDM threshold values that correspond to a “non-perceptible” difference. Using the above validation results, we focused on important variables in fast MR imaging, especially in spiral MRI and advanced parallel MRI techniques, including the SENSE regularization techniques and the GRAPPA reconstruction techniques. Data was generated from real scanners or simulated from the digital phantoms. Various acquisition parameters and reconstruction algorithms were combined to generate thousands of images for each application. CASE-PDM was used to quantitatively compare those images, and the CASE-PDM scores was analyzed statistically to give helpful hints for the engineers. In addition, a new modification of GRAPPA method called Robust GRAPPA was proposed. Robust GRAPPA was compared with conventional GRAPPA and obvious improvement in image quality was observed.","abstract_has_math":false,"creators":["Huo, Donglai"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Wilson, David"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007","date_published":"2007","updated_at":"2026-11-27T04:14:31Z","subjects":["Engineering, Biomedical","Perceptual Difference Model","CASE-PDM","Image Quality","Magnetic Resonance Imaging","Spiral Imaging","Parallel Imaging"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1155913518","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1155913518","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1155913518","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1155913518","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wilson, David"]},{"key":"dc:creator","label":"Author","values":["Huo, Donglai"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2007"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Biomedical","Perceptual Difference Model","CASE-PDM","Image Quality","Magnetic Resonance Imaging","Spiral Imaging","Parallel Imaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1155913518"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Magnetic resonance imaging (MRI) has been widely used in the diagnosis and treatment of various diseases. The principle of encoding object contrast in the resonance spectrum gives MRI almost unlimited ways to acquire and reconstruct an image, but at the same time, arises the problem of how to effectively evaluate and optimize these parameters and methods. The perceptual difference model (CASE-PDM) is a quantitative image quality evaluation tool developed in our lab and has been successfully applied to several applications of MRI. It determines the visual difference between a high quality reference image and a more quickly obtained, but possibly degraded, MR image. A low CASE-PDM score indicates similarity of the images, and there is a threshold, below which, one cannot detect a difference between the two. The goal of our research is to use the CASE-PDM model to evaluate the image quality in fast MRI and to optimize the parameters. Two Human subject experiments, DSCQS and ADF, were designed and performed to validate the CASE-PDM model. The CASE-PDM predictions are closely correlated with the human subjects predictions, for both low-degradation and high-degradation images. We also found CASE-PDM threshold values that correspond to a “non-perceptible” difference. Using the above validation results, we focused on important variables in fast MR imaging, especially in spiral MRI and advanced parallel MRI techniques, including the SENSE regularization techniques and the GRAPPA reconstruction techniques. Data was generated from real scanners or simulated from the digital phantoms. Various acquisition parameters and reconstruction algorithms were combined to generate thousands of images for each application. CASE-PDM was used to quantitatively compare those images, and the CASE-PDM scores was analyzed statistically to give helpful hints for the engineers. In addition, a new modification of GRAPPA method called Robust GRAPPA was proposed. Robust GRAPPA was compared with conventional GRAPPA and obvious improvement in image quality was observed."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.182","3.5 MB"]},{"key":"dc:title","label":"Title","values":["Quantitative Image Quality Evaluation of Fast Magnetic Resonance Imaging"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wilson, David"],"dc:creator":["Huo, Donglai"],"dc:date":["2007"],"dc:description":["Magnetic resonance imaging (MRI) has been widely used in the diagnosis and treatment of various diseases. The principle of encoding object contrast in the resonance spectrum gives MRI almost unlimited ways to acquire and reconstruct an image, but at the same time, arises the problem of how to effectively evaluate and optimize these parameters and methods. The perceptual difference model (CASE-PDM) is a quantitative image quality evaluation tool developed in our lab and has been successfully applied to several applications of MRI. It determines the visual difference between a high quality reference image and a more quickly obtained, but possibly degraded, MR image. A low CASE-PDM score indicates similarity of the images, and there is a threshold, below which, one cannot detect a difference between the two. The goal of our research is to use the CASE-PDM model to evaluate the image quality in fast MRI and to optimize the parameters. Two Human subject experiments, DSCQS and ADF, were designed and performed to validate the CASE-PDM model. The CASE-PDM predictions are closely correlated with the human subjects predictions, for both low-degradation and high-degradation images. We also found CASE-PDM threshold values that correspond to a “non-perceptible” difference. Using the above validation results, we focused on important variables in fast MR imaging, especially in spiral MRI and advanced parallel MRI techniques, including the SENSE regularization techniques and the GRAPPA reconstruction techniques. Data was generated from real scanners or simulated from the digital phantoms. Various acquisition parameters and reconstruction algorithms were combined to generate thousands of images for each application. CASE-PDM was used to quantitatively compare those images, and the CASE-PDM scores was analyzed statistically to give helpful hints for the engineers. In addition, a new modification of GRAPPA method called Robust GRAPPA was proposed. Robust GRAPPA was compared with conventional GRAPPA and obvious improvement in image quality was observed."],"dc:format":["application/pdf","p.182","3.5 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1155913518"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Biomedical","Perceptual Difference Model","CASE-PDM","Image Quality","Magnetic Resonance Imaging","Spiral Imaging","Parallel Imaging"],"dc:title":["Quantitative Image Quality Evaluation of Fast Magnetic Resonance Imaging"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:31Z"}