{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1169749200"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1169749200","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"NEW DIRECTIONS IN THE DESIGN OF MRI GRADIENT COILS","abstract":"In this dissertation new designs for gradient coils are presented. The principal work is on better shielding for fringe field reduction. Fringe fields from gradient coils produce eddy currents in surrounding metal structures. Such eddy currents can degrade image quality and lead to acoustic noise. Our new shielded gradient coil designs that feature the inclusion of an endcap have significantly reduced fringe field at the cryostat inner bore. We discuss the degree to which the suppression of peak fringe fields corresponds to a reduction in the acoustic noise generated near the end of the warm bore. Energy efficient capped actively shielded elliptical gradient coils are also designed. In addition, a design for a very short, symmetrical, and winged X-gradient insertable head coil is presented. Apart from the uniformity along the z-axis direction the new coil achieved characteristics similar to that of coils almost twice its length.","abstract_html":"In this dissertation new designs for gradient coils are presented. The principal work is on better shielding for fringe field reduction. Fringe fields from gradient coils produce eddy currents in surrounding metal structures. Such eddy currents can degrade image quality and lead to acoustic noise. Our new shielded gradient coil designs that feature the inclusion of an endcap have significantly reduced fringe field at the cryostat inner bore. We discuss the degree to which the suppression of peak fringe fields corresponds to a reduction in the acoustic noise generated near the end of the warm bore. Energy efficient capped actively shielded elliptical gradient coils are also designed. In addition, a design for a very short, symmetrical, and winged X-gradient insertable head coil is presented. Apart from the uniformity along the z-axis direction the new coil achieved characteristics similar to that of coils almost twice its length.","abstract_has_math":false,"creators":["BAIG, TANVIR N."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":["Brown, Robert"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-01-25","date_published":"2007-01-25","updated_at":"2026-11-26T03:17:16Z","subjects":["Physics, General","Endcap","GRADIENT COILS","Elliptic","Z-gradient","X-gradient"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1169749200","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1169749200","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1169749200","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1169749200","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Brown, Robert"]},{"key":"dc:creator","label":"Author","values":["BAIG, TANVIR N."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2007-01-25"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics, General","Endcap","GRADIENT COILS","Elliptic","Z-gradient","X-gradient"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1169749200"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this dissertation new designs for gradient coils are presented. The principal work is on better shielding for fringe field reduction. Fringe fields from gradient coils produce eddy currents in surrounding metal structures. Such eddy currents can degrade image quality and lead to acoustic noise. Our new shielded gradient coil designs that feature the inclusion of an endcap have significantly reduced fringe field at the cryostat inner bore. We discuss the degree to which the suppression of peak fringe fields corresponds to a reduction in the acoustic noise generated near the end of the warm bore. Energy efficient capped actively shielded elliptical gradient coils are also designed. In addition, a design for a very short, symmetrical, and winged X-gradient insertable head coil is presented. Apart from the uniformity along the z-axis direction the new coil achieved characteristics similar to that of coils almost twice its length."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.186","4.19 MB"]},{"key":"dc:title","label":"Title","values":["NEW DIRECTIONS IN THE DESIGN OF MRI GRADIENT COILS"]}]}],"canonical_facts":{"dc:contributor":["Brown, Robert"],"dc:creator":["BAIG, TANVIR N."],"dc:date":["2007-01-25"],"dc:description":["In this dissertation new designs for gradient coils are presented. The principal work is on better shielding for fringe field reduction. Fringe fields from gradient coils produce eddy currents in surrounding metal structures. Such eddy currents can degrade image quality and lead to acoustic noise. Our new shielded gradient coil designs that feature the inclusion of an endcap have significantly reduced fringe field at the cryostat inner bore. We discuss the degree to which the suppression of peak fringe fields corresponds to a reduction in the acoustic noise generated near the end of the warm bore. Energy efficient capped actively shielded elliptical gradient coils are also designed. In addition, a design for a very short, symmetrical, and winged X-gradient insertable head coil is presented. Apart from the uniformity along the z-axis direction the new coil achieved characteristics similar to that of coils almost twice its length."],"dc:format":["application/pdf","p.186","4.19 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1169749200"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Physics, General","Endcap","GRADIENT COILS","Elliptic","Z-gradient","X-gradient"],"dc:title":["NEW DIRECTIONS IN THE DESIGN OF MRI GRADIENT COILS"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:17:16Z"}