{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1194467225"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1194467225","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"REAL-TIME AUTOMATED SLEEP SCORING OF NEONATES","abstract":"Observation of sleep state can provide very useful information for understanding brain disorders in neonates. The neurologist visually scores sleep state according to the polysomnogram. Neurologist expertise is a critical factor for the success of the sleep scoring; furthermore, visual sleep scoring is extreme time consuming. Computer based sleep scoring systems has been used to assist neurologist; however, most of them are not practical in real-time processing. The objective of this research is to develop real-time automated active/quiet sleep and arousal/non-arousal scoring system in healthy neonates. The active and quiet sleep classifier based on Discrete Wavelet Transform, support vector machine, and principle component analysis has satisfied correct classification rates. The proposed arousal detection system based on appearance of events including changes in the EEG, increases in the EMG amplitude, irregular breathing, and body movements, has unsatisfied correct rate because of ambiguous arousal scoring rules and incomplete information of scored arousals.","abstract_html":"Observation of sleep state can provide very useful information for understanding brain disorders in neonates. The neurologist visually scores sleep state according to the polysomnogram. Neurologist expertise is a critical factor for the success of the sleep scoring; furthermore, visual sleep scoring is extreme time consuming. Computer based sleep scoring systems has been used to assist neurologist; however, most of them are not practical in real-time processing. The objective of this research is to develop real-time automated active/quiet sleep and arousal/non-arousal scoring system in healthy neonates. The active and quiet sleep classifier based on Discrete Wavelet Transform, support vector machine, and principle component analysis has satisfied correct classification rates. The proposed arousal detection system based on appearance of events including changes in the EEG, increases in the EMG amplitude, irregular breathing, and body movements, has unsatisfied correct rate because of ambiguous arousal scoring rules and incomplete information of scored arousals.","abstract_has_math":false,"creators":["Thungtong, Anurak"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Loparo, Kenneth"],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-11-27T04:14:31Z","subjects":["Engineering, System Science","Sleep scoring","EEG","Automated","Real-time","Neonate","Wavelet","PCA","SVM"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1194467225","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1194467225","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1194467225","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1194467225","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Loparo, Kenneth"]},{"key":"dc:creator","label":"Author","values":["Thungtong, Anurak"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, System Science","Sleep scoring","EEG","Automated","Real-time","Neonate","Wavelet","PCA","SVM"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1194467225"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Observation of sleep state can provide very useful information for understanding brain disorders in neonates. The neurologist visually scores sleep state according to the polysomnogram. Neurologist expertise is a critical factor for the success of the sleep scoring; furthermore, visual sleep scoring is extreme time consuming. Computer based sleep scoring systems has been used to assist neurologist; however, most of them are not practical in real-time processing. The objective of this research is to develop real-time automated active/quiet sleep and arousal/non-arousal scoring system in healthy neonates. The active and quiet sleep classifier based on Discrete Wavelet Transform, support vector machine, and principle component analysis has satisfied correct classification rates. The proposed arousal detection system based on appearance of events including changes in the EEG, increases in the EMG amplitude, irregular breathing, and body movements, has unsatisfied correct rate because of ambiguous arousal scoring rules and incomplete information of scored arousals."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.86","747.8 KB"]},{"key":"dc:title","label":"Title","values":["REAL-TIME AUTOMATED SLEEP SCORING OF NEONATES"]}]}],"canonical_facts":{"dc:contributor.advisor":["Loparo, Kenneth"],"dc:creator":["Thungtong, Anurak"],"dc:date":["2008"],"dc:description":["Observation of sleep state can provide very useful information for understanding brain disorders in neonates. The neurologist visually scores sleep state according to the polysomnogram. Neurologist expertise is a critical factor for the success of the sleep scoring; furthermore, visual sleep scoring is extreme time consuming. Computer based sleep scoring systems has been used to assist neurologist; however, most of them are not practical in real-time processing. The objective of this research is to develop real-time automated active/quiet sleep and arousal/non-arousal scoring system in healthy neonates. The active and quiet sleep classifier based on Discrete Wavelet Transform, support vector machine, and principle component analysis has satisfied correct classification rates. The proposed arousal detection system based on appearance of events including changes in the EEG, increases in the EMG amplitude, irregular breathing, and body movements, has unsatisfied correct rate because of ambiguous arousal scoring rules and incomplete information of scored arousals."],"dc:format":["application/pdf","p.86","747.8 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1194467225"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, System Science","Sleep scoring","EEG","Automated","Real-time","Neonate","Wavelet","PCA","SVM"],"dc:title":["REAL-TIME AUTOMATED SLEEP SCORING OF NEONATES"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:31Z"}